Nader El-Zarif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nader El-Zarif has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Hassan
Polytechnique Montreal
3 shared publications - Yvon Savaria
Department of Electrical Engineering, Polytechnique Montreal, Montreal, QC H3T lJ4, Canada
3 shared publications - Aziz Oukaira
Electrical Engineering Department, Université de Moncton, Moncton, NB E1A 3E9, Canada
2 shared publications - Mohamed Ali
Department of Electrical Engineering, Polytechnique Montral, Montreal, QC, Canada
2 shared publications - Mostafa Amer
Department of Electrical Engineering, Polytechnique Montréal, Montréal, QC H3T 1J4, Canada
2 shared publications - Ahmed Lakhssassi
Department of Engineering and Computer Science, University of Quebec in Outaouais, Gatineau, QC J9A 1L8, Canada
1 shared publication
Latest Publications
- Open Access
- 3 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 188200-188216
A Systematic Approach for PLL-Based Zeta Power Converter Control
This paper presents a systematic approach for Zeta power converter control, a versatile solution designed for systems where the power supply is prone to fluctuations. The optimized controller exploits a detailed model of the power stage and adjusts the system parameters to ensure stability over a wide range of loads and loading conditions. A detailed model for the Zeta converter is developed, considering important power stage parameters such as the ON resistance of power transistors and inductor series resistance. The control strategy utilizes a phase-locked loop, which includes a loop filter along with an additional lead compensator circuit to improve the loop phase margin, thereby enhancing the system’s dynamic response and stability. The proposed graphical approach facilitates intuitive controller design and tuning, providing a robust framework for managing converter dynamics. The system stability and performance are validated through extensive transient simulations using a standard 180 nm CMOS technology, demonstrating the converter’s effectiveness in maintaining stable output under variable input conditions. Experimental results show that the proposed closed-loop Zeta converter can achieve a peak efficiency of 94% when the load resistance is 10 Ω, and it can handle current loads up to 3A. The system operates at a switching frequency of 85 kHz and can support an input voltage range from 6V to 34V while maintaining stable output. During reference tracking tests, the system demonstrates excellent transient response, with a settling time of 12.5 ms and a peak overshoot of 3.9V. Additionally, compared to similar works, the system exhibits superior normalized transient load regulation, highlighting the robustness of the proposed control strategy.
- 3 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 188200-188216
Open AccessA Systematic Approach for PLL-Based Zeta Power Converter Control
This paper presents a systematic approach for Zeta power converter control, a versatile solution designed for systems where the power supply is prone to fluctuations. The optimized controller exploits a detailed model of the power stage and adjusts the system parameters to ensure stability over a wide range of loads and loading conditions. A detailed model for the Zeta converter is developed, considering important power stage parameters such as the ON resistance of power transistors and inductor series resistance. The control strategy utilizes a phase-locked loop, which includes a loop filter along with an additional lead compensator circuit to improve the loop phase margin, thereby enhancing the system’s dynamic response and stability. The proposed graphical approach facilitates intuitive controller design and tuning, providing a robust framework for managing converter dynamics. The system stability and performance are validated through extensive transient simulations using a standard 180 nm CMOS technology, demonstrating the converter’s effectiveness in maintaining stable output under variable input conditions. Experimental results show that the proposed closed-loop Zeta converter can achieve a peak efficiency of 94% when the load resistance is 10 Ω, and it can handle current loads up to 3A. The system operates at a switching frequency of 85 kHz and can support an input voltage range from 6V to 34V while maintaining stable output. During reference tracking tests, the system demonstrates excellent transient response, with a settling time of 12.5 ms and a peak overshoot of 3.9V. Additionally, compared to similar works, the system exhibits superior normalized transient load regulation, highlighting the robustness of the proposed control strategy.
- Open Access
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 143842-143853
Novel Peak-Source-Scanning (NPSS) Model for Thermal Control of Systems-in-Package (SiP)
One of the fast-growing electronic integration technologies in the modern high-density microelectronics industry is System-in-Package (SiP). It is expected to accelerate application development when reducing implementation risks with optimized codes. However, monitoring the thermal behavior of every chip in SiPs is challenging. This paper proposes a Novel Peak Source-Scanning (NPSS) algorithm based on the Gradient Direction Sensors (GDS) method. The proposed algorithm can detect and locate thermal peaks on any SiP. Detecting such peaks is vital for thermal monitoring and stress management on high-density semiconductor devices to avoid induced thermo-mechanical stresses. Furthermore, the NPSS algorithm can manage and monitor silicon chips with Multiple Heat Sources (MHS). To assess this algorithm, we used tools from COMSOL Multiphysics® and MATLAB® for Temperature-prediction (Tp), and Temperature-estimation (Te), respectively. Our simulations use the generalized GDS methodology for MHS using the finite element method (FEM) to highlight our NPSS capabilities to predict on-chip thermal peaks with a maximum error of 1.27 K (Kelvin).
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 143842-143853
Open AccessNovel Peak-Source-Scanning (NPSS) Model for Thermal Control of Systems-in-Package (SiP)
One of the fast-growing electronic integration technologies in the modern high-density microelectronics industry is System-in-Package (SiP). It is expected to accelerate application development when reducing implementation risks with optimized codes. However, monitoring the thermal behavior of every chip in SiPs is challenging. This paper proposes a Novel Peak Source-Scanning (NPSS) algorithm based on the Gradient Direction Sensors (GDS) method. The proposed algorithm can detect and locate thermal peaks on any SiP. Detecting such peaks is vital for thermal monitoring and stress management on high-density semiconductor devices to avoid induced thermo-mechanical stresses. Furthermore, the NPSS algorithm can manage and monitor silicon chips with Multiple Heat Sources (MHS). To assess this algorithm, we used tools from COMSOL Multiphysics® and MATLAB® for Temperature-prediction (Tp), and Temperature-estimation (Te), respectively. Our simulations use the generalized GDS methodology for MHS using the finite element method (FEM) to highlight our NPSS capabilities to predict on-chip thermal peaks with a maximum error of 1.27 K (Kelvin).
- Open Access
Calibration of Ring Oscillator-Based Integrated Temperature Sensors for Power Management Systems
This paper details the development and validation of a temperature sensing methodology using an un-trimmed oscillator-based integrated sensor implemented in the 0.18-m SOI XFAB process, with a focus on thermal monitoring in system-on-chip (SoC) based DC-DC converters. Our study identifies a quadratic relationship between the oscillator output frequency and temperature, which forms the basis of our proposed calibration mechanism. This mechanism aims at mitigating process variation effects, enabling accurate temperature-to-frequency mapping. Our research proposes and characterizes several trimming-free calibration techniques, covering a spectrum from zero to thirty-one frequency-temperature measurement points. Notably, the Corrected One-Point calibration method, requiring only a single ambient temperature measurement, emerges as a practical solution that removes the need for a temperature chamber. This method, after adjustment, successfully reduces the maximum error to within °C. Additionally, the Two-Point calibration method demonstrates improved precision with a maximum positive error of +1.56 °C at −15 °C and a maximum negative error of −3.13 °C at +10 °C ( value of 0.9958). The Three-Point calibration method performed similarly, yielding an value of 0.9956. The findings of this study indicate that competitive results in temperature sensor calibration can be achieved without circuit trimming, offering a viable alternative or a complementary approach to traditional trimming techniques.Open AccessCalibration of Ring Oscillator-Based Integrated Temperature Sensors for Power Management Systems
This paper details the development and validation of a temperature sensing methodology using an un-trimmed oscillator-based integrated sensor implemented in the 0.18-m SOI XFAB process, with a focus on thermal monitoring in system-on-chip (SoC) based DC-DC converters. Our study identifies a quadratic relationship between the oscillator output frequency and temperature, which forms the basis of our proposed calibration mechanism. This mechanism aims at mitigating process variation effects, enabling accurate temperature-to-frequency mapping. Our research proposes and characterizes several trimming-free calibration techniques, covering a spectrum from zero to thirty-one frequency-temperature measurement points. Notably, the Corrected One-Point calibration method, requiring only a single ambient temperature measurement, emerges as a practical solution that removes the need for a temperature chamber. This method, after adjustment, successfully reduces the maximum error to within °C. Additionally, the Two-Point calibration method demonstrates improved precision with a maximum positive error of +1.56 °C at −15 °C and a maximum negative error of −3.13 °C at +10 °C ( value of 0.9958). The Three-Point calibration method performed similarly, yielding an value of 0.9956. The findings of this study indicate that competitive results in temperature sensor calibration can be achieved without circuit trimming, offering a viable alternative or a complementary approach to traditional trimming techniques.