Jun Tao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jun Tao has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Longyang Wang
Anhui University
4 shared publications - Qianlong Zhu
School of Electrical Engineering and Automation, Anhui University, Hefei, China
4 shared publications - Tianbai Deng
Anhui University
4 shared publications - Rixin Wang
Anhui University
3 shared publications - Yiyun Huang
Chinese Academy of Sciences, Institute of Plasma Physics, Hefei Institutes of Physical Science, Hefei, China
3 shared publications Congguo Gong
Hefei Comprehensive National Science Center (Anhui Energy Laboratory)
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (11) , 5901-5910
A Dual-Channel GaN HEMT Nanosecond Pulse Generator With Enhanced Rising Edge and Frequency-Doubling Operation
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (11) , 5901-5910
A Dual-Channel GaN HEMT Nanosecond Pulse Generator With Enhanced Rising Edge and Frequency-Doubling Operation
- Open Access
Local Faulted-Section Identification for Pole-to-Pole Faults in MVDC Ring Networks Using Hybrid DC Circuit-Breaker Commutation Characteristics
Fast and selective faulted-section identification is challenging in multiterminal medium-voltage DC (MVDC) ring networks because the initial fault transient is affected by converter dynamics, fault resistance, line parameters, and multiple feeding paths. This paper proposes a local identification method for pole-to-pole faults in a four-terminal ±10 kV modular multilevel converter (MMC)-based MVDC ring network, using hybrid DC circuit-breaker (HCB) commutation characteristics. The breaker-current magnitude is used to initiate hybrid DC circuit breaker operation. The identification feature is the magnitude of the mechanical-switch (MS) current slope estimated during the passive intervals of the clamped commutation stage. This feature is used to classify faults as in-zone or out-of-zone. An in-zone fault is confirmed when three consecutive valid slope estimates satisfy the threshold criterion. Because only local HCB measurements and control signals are required for online identification, the method does not rely on interterminal communication or time synchronization. Offline threshold setting, however, requires the network topology and component parameters. After classification, the HCBs bounding the faulted line continue the interruption process, whereas triggered out-of-zone HCBs maintain semiconductor conduction and subsequently reclose their MSs. PSCAD/EMTDC simulations on a four-terminal ±10 kV MVDC ring network demonstrate correct faulted-section identification at the end of a 200 μs decision interval measured from local HCB triggering, using a baseline protection sampling interval of 1 μs, over the tested fault locations and fault resistance. Additional sampling-interval tests show no observed identification failures at 1 and 2 μs for the evaluated cases, whereas failures occur at 5 μs. Additional bounded measurement-noise tests show correct discrimination for the benchmark fault at the tested nominal noise levels up to 1% for the selected noise realizations. These results demonstrate the feasibility for the studied configuration; broader parameter variations and practical measurement and execution constraints require further validation.
Open AccessLocal Faulted-Section Identification for Pole-to-Pole Faults in MVDC Ring Networks Using Hybrid DC Circuit-Breaker Commutation Characteristics
Fast and selective faulted-section identification is challenging in multiterminal medium-voltage DC (MVDC) ring networks because the initial fault transient is affected by converter dynamics, fault resistance, line parameters, and multiple feeding paths. This paper proposes a local identification method for pole-to-pole faults in a four-terminal ±10 kV modular multilevel converter (MMC)-based MVDC ring network, using hybrid DC circuit-breaker (HCB) commutation characteristics. The breaker-current magnitude is used to initiate hybrid DC circuit breaker operation. The identification feature is the magnitude of the mechanical-switch (MS) current slope estimated during the passive intervals of the clamped commutation stage. This feature is used to classify faults as in-zone or out-of-zone. An in-zone fault is confirmed when three consecutive valid slope estimates satisfy the threshold criterion. Because only local HCB measurements and control signals are required for online identification, the method does not rely on interterminal communication or time synchronization. Offline threshold setting, however, requires the network topology and component parameters. After classification, the HCBs bounding the faulted line continue the interruption process, whereas triggered out-of-zone HCBs maintain semiconductor conduction and subsequently reclose their MSs. PSCAD/EMTDC simulations on a four-terminal ±10 kV MVDC ring network demonstrate correct faulted-section identification at the end of a 200 μs decision interval measured from local HCB triggering, using a baseline protection sampling interval of 1 μs, over the tested fault locations and fault resistance. Additional sampling-interval tests show no observed identification failures at 1 and 2 μs for the evaluated cases, whereas failures occur at 5 μs. Additional bounded measurement-noise tests show correct discrimination for the benchmark fault at the tested nominal noise levels up to 1% for the selected noise realizations. These results demonstrate the feasibility for the studied configuration; broader parameter variations and practical measurement and execution constraints require further validation.
- 14 July 2026
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 24 (8) , 2100-2114
Uncertainty-Aware and Interpretable Fault Diagnosis for Complex Engineering Systems Using Adaptive Rule-Based Reasoning
- 14 July 2026
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 24 (8) , 2100-2114
Uncertainty-Aware and Interpretable Fault Diagnosis for Complex Engineering Systems Using Adaptive Rule-Based Reasoning
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (1) , 4-16
Angular Acceleration Transient Damping VSG for Paralleled Inverters in Islanded Microgrid With Constrained RoCoF and Suppressed Power Oscillation
Paralleled VSGs can collect resources from multiple devices, forming a large virtual inertia to stabilize an islanded microgrid. This enables an independent way for flexible utilization of renewable energy. Paralleled VSGs often suffer from active power oscillation when countering disturbances. Many efforts have been devoted to solving the problem, however, improved VSG control may have a high rate of change of frequency (RoCoF), leading to load shedding, relay misoperation, and cascaded collapse. Nevertheless, RoCoF constraint is barely discussed in existing literature. This paper proposes an angular acceleration transient damping VSG control for paralleled inverters, to constrain RoCoF and suppress power oscillation simultaneously. This is achieved by adding a negative feedback loop of angular acceleration into existing transient damping VSG, increasing virtual moment of inertia to constrain RoCoF. The side effect of virtual moment increment is a possible enlargement of power oscillation, this is further solved by utilizing an inertial element within the feedback loop to provide an extra damping effect, sustaining good oscillation suppression. Simulation experiments indicate that the proposed method has a much lower RoCoF and slightly better oscillation suppression than transient damping VSG, and holds an overall performance much better than traditional method.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (1) , 4-16
Angular Acceleration Transient Damping VSG for Paralleled Inverters in Islanded Microgrid With Constrained RoCoF and Suppressed Power Oscillation
Paralleled VSGs can collect resources from multiple devices, forming a large virtual inertia to stabilize an islanded microgrid. This enables an independent way for flexible utilization of renewable energy. Paralleled VSGs often suffer from active power oscillation when countering disturbances. Many efforts have been devoted to solving the problem, however, improved VSG control may have a high rate of change of frequency (RoCoF), leading to load shedding, relay misoperation, and cascaded collapse. Nevertheless, RoCoF constraint is barely discussed in existing literature. This paper proposes an angular acceleration transient damping VSG control for paralleled inverters, to constrain RoCoF and suppress power oscillation simultaneously. This is achieved by adding a negative feedback loop of angular acceleration into existing transient damping VSG, increasing virtual moment of inertia to constrain RoCoF. The side effect of virtual moment increment is a possible enlargement of power oscillation, this is further solved by utilizing an inertial element within the feedback loop to provide an extra damping effect, sustaining good oscillation suppression. Simulation experiments indicate that the proposed method has a much lower RoCoF and slightly better oscillation suppression than transient damping VSG, and holds an overall performance much better than traditional method.
- Open Access
Promoting the Green Transformation of Traditional Ships in Anhui Province: A Model Prediction Cost Analysis Algorithm for a New Electrification Transformation Scheme Using Lithium Iron Phosphate Battery
Promoting the green transformation of traditional diesel-powered ships is crucial for achieving carbon peaking and carbon neutrality goals. This study focuses on diesel-engine ships operating in the inland river areas of Anhui Province, China. It proposes two electrification retrofit schemes based mainly on lithium iron phosphate (LIP) batteries: full electrification and diesel-engine redundancy. The economic and environmental impacts of these schemes are analyzed and compared with those of conventional diesel-powered ships. A cost prediction algorithm based on model prediction is proposed, supported by a mathematical model for cost analysis. Results indicate that for electric tankers to become economically viable, battery costs must decrease through yearly improvements in energy density and reduced degradation rates. Additionally, government support is essential, such as raising carbon prices and providing subsidies—either an annual operational subsidy of CNY 80,000 or an initial construction subsidy of CNY 500,000. The study concludes that continued advances in battery technology, together with policy and financial support, will accelerate the large-scale electrification of ships.
Open AccessPromoting the Green Transformation of Traditional Ships in Anhui Province: A Model Prediction Cost Analysis Algorithm for a New Electrification Transformation Scheme Using Lithium Iron Phosphate Battery
Promoting the green transformation of traditional diesel-powered ships is crucial for achieving carbon peaking and carbon neutrality goals. This study focuses on diesel-engine ships operating in the inland river areas of Anhui Province, China. It proposes two electrification retrofit schemes based mainly on lithium iron phosphate (LIP) batteries: full electrification and diesel-engine redundancy. The economic and environmental impacts of these schemes are analyzed and compared with those of conventional diesel-powered ships. A cost prediction algorithm based on model prediction is proposed, supported by a mathematical model for cost analysis. Results indicate that for electric tankers to become economically viable, battery costs must decrease through yearly improvements in energy density and reduced degradation rates. Additionally, government support is essential, such as raising carbon prices and providing subsidies—either an annual operational subsidy of CNY 80,000 or an initial construction subsidy of CNY 500,000. The study concludes that continued advances in battery technology, together with policy and financial support, will accelerate the large-scale electrification of ships.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (11) , 3440-3452
Enhanced Coordinated Control of ITER Power Supplies and Reactive Power Compensation System
The operational stability of ITER power supplies requires the optimal coordination of the reactive power compensation (RPC) system, which comprises a thyristor-controlled reactor (TCR) and tuned filters, particularly under high-dynamic load conditions. Existing RPC control methods have inherent limitations, such as high latency, model dependency, and poor disturbance rejection, which restrict their ability to meet stringent regulation demands during extreme plasma control scenarios. This article develops a forecasting- $Q$ -linear active disturbance rejection control (FQLADRC) framework that integrates an extended state observer (ESO) and a proportional-derivative (PD) controller, with predictive $Q$ commands calculated by coordinating plasma control system (PCS) reference signals. The proposed control strategy achieves higher precision in dynamic $Q$ regulation, faster transient responses, and strong robustness against model deviations and environmental interference. Key $Q$ -linear active disturbance rejection control (QLADRC) parameters are determined via bandwidth parameterization with engineering configurations. Simulations validate the algorithm’s efficacy, showing significant reductions in grid $Q$ oscillations and voltage fluctuations during load disturbances, alongside improved ac busbar stability. Furthermore, this work provides guidance for optimizing RPC systems in other high-capacity, strong-impulse power grids, with resilience to internal uncertainties (e.g., response delays and parameter perturbations) and external disturbances (e.g., harmonics and operational noise).
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (11) , 3440-3452
Enhanced Coordinated Control of ITER Power Supplies and Reactive Power Compensation System
The operational stability of ITER power supplies requires the optimal coordination of the reactive power compensation (RPC) system, which comprises a thyristor-controlled reactor (TCR) and tuned filters, particularly under high-dynamic load conditions. Existing RPC control methods have inherent limitations, such as high latency, model dependency, and poor disturbance rejection, which restrict their ability to meet stringent regulation demands during extreme plasma control scenarios. This article develops a forecasting- $Q$ -linear active disturbance rejection control (FQLADRC) framework that integrates an extended state observer (ESO) and a proportional-derivative (PD) controller, with predictive $Q$ commands calculated by coordinating plasma control system (PCS) reference signals. The proposed control strategy achieves higher precision in dynamic $Q$ regulation, faster transient responses, and strong robustness against model deviations and environmental interference. Key $Q$ -linear active disturbance rejection control (QLADRC) parameters are determined via bandwidth parameterization with engineering configurations. Simulations validate the algorithm’s efficacy, showing significant reductions in grid $Q$ oscillations and voltage fluctuations during load disturbances, alongside improved ac busbar stability. Furthermore, this work provides guidance for optimizing RPC systems in other high-capacity, strong-impulse power grids, with resilience to internal uncertainties (e.g., response delays and parameter perturbations) and external disturbances (e.g., harmonics and operational noise).
- 30 November 2024
- Published by Springer Nature
- p. 707-727
Structure Design and Electromagnetic Analysis of High-Frequency and High-Voltage Transformer for DC High Voltage Power Supply Towards BNCT
- 30 November 2024
- Published by Springer Nature
- p. 707-727
Structure Design and Electromagnetic Analysis of High-Frequency and High-Voltage Transformer for DC High Voltage Power Supply Towards BNCT
- 3 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
In Situ Inversion of Lithium-Ion Battery Pack Unbalanced Current for Inconsistency Detection Using Magnetic Field Imaging
The performance inconsistency of lithium-ion battery packs is one of the key factors that lead to their accelerated lifespan degradation and reduced reliability. Hence, it is of great significance to accurately detect the consistency of cell parameters within the pack without destructive testing. The working current of the cell is the most direct and effective parameter to characterize the consistency of its module. However, cell level current is not monitored in commercial battery packs due to the limitations of current sensors. Therefore, this work proposes an inversion method using in situ magnetic field imaging for detecting unbalanced current induced by performance inconsistency of the pack. Through elucidating the superposition property of current-induced magnetic field between cells, a current inversion model for the battery pack is constructed, with the model principle and solution method given. Battery packs with different configuration structures are designed, simulated, and measured. The results show that this method can reduce the interference of susceptibility-induced magnetic field and achieve milliampere-level current calculated accuracy. This provides a new way to quickly and accurately evaluate the performance consistency of battery packs, and provides a technical guarantee for battery pack service performance testing and maintenance.
- 3 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
In Situ Inversion of Lithium-Ion Battery Pack Unbalanced Current for Inconsistency Detection Using Magnetic Field Imaging
The performance inconsistency of lithium-ion battery packs is one of the key factors that lead to their accelerated lifespan degradation and reduced reliability. Hence, it is of great significance to accurately detect the consistency of cell parameters within the pack without destructive testing. The working current of the cell is the most direct and effective parameter to characterize the consistency of its module. However, cell level current is not monitored in commercial battery packs due to the limitations of current sensors. Therefore, this work proposes an inversion method using in situ magnetic field imaging for detecting unbalanced current induced by performance inconsistency of the pack. Through elucidating the superposition property of current-induced magnetic field between cells, a current inversion model for the battery pack is constructed, with the model principle and solution method given. Battery packs with different configuration structures are designed, simulated, and measured. The results show that this method can reduce the interference of susceptibility-induced magnetic field and achieve milliampere-level current calculated accuracy. This provides a new way to quickly and accurately evaluate the performance consistency of battery packs, and provides a technical guarantee for battery pack service performance testing and maintenance.