Zongman Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zongman Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hossam Haick
Technion – Israel Institute of Technology
2 shared publications - Jiawei Yang
Department of Chemical Engineering, Guangdong Technion-Israel Institute of Technology, 241 Daxue Road, Shantou, Guangdong 515063, China
2 shared publications - Sunghoon Lee
RIKEN Center for Emergent Matter Science (CEMS), 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
2 shared publications - Takao Someya
Department of Electrical Engineering and Information Systems, Graduate School of Engineering, The University of Tokyo, Tokyo, Japan
2 shared publications - Tomoyuki Yokota
The University of Tokyo 7-3-1 Hongo, Bunkyo-ku
2 shared publications - Yan Wang
Department of Chemical Engineering, Guangdong Technion-Israel Institute of Technology, Shantou, China
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 19 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (38) , eadt2286
A 2.7-μm-thick robust, permeable, and antifreezing hydrogel electrode for long-term ambulatory health monitoring
Adaptable hydrogel bioelectronics that sustain long-term, uninterrupted operation are critical for early disease diagnosis and personalized health care. However, conventional hydrogel electrodes suffer from mechanical fragility, rapid dehydration, freezing, and poor comfort because of thickness-induced interfacial gaps. We report a 2.7-micrometer-thick robust, permeable, and antifreezing hydrogel electrode for high-quality 8-day electrophysiological monitoring under everyday scenarios. The ultrathin electrode is fabricated using gelatin hydrogels with temperature-controlled phase change properties reinforced by nanomesh while incorporating lithium chloride, and a binary solvent achieves antifreezing and antidehydration characteristics. The design minimizes flexural rigidity, resulting in high interfacial adhesion energy with human skin, and enhances gas (air, oxygen, and carbon dioxide) permeance and water vapor transmission rate. Consequently, the ultrathin hydrogel electrode exhibits high biocompatibility, superior wear comfort, and minimized motion and sweat artifacts, enabling reliable, uninterrupted, wireless health monitoring over eight consecutive days across various real-life activities and adaptation to cold environments.
- 19 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (38) , eadt2286
Top Cited PapersOpen AccessA 2.7-μm-thick robust, permeable, and antifreezing hydrogel electrode for long-term ambulatory health monitoring
Adaptable hydrogel bioelectronics that sustain long-term, uninterrupted operation are critical for early disease diagnosis and personalized health care. However, conventional hydrogel electrodes suffer from mechanical fragility, rapid dehydration, freezing, and poor comfort because of thickness-induced interfacial gaps. We report a 2.7-micrometer-thick robust, permeable, and antifreezing hydrogel electrode for high-quality 8-day electrophysiological monitoring under everyday scenarios. The ultrathin electrode is fabricated using gelatin hydrogels with temperature-controlled phase change properties reinforced by nanomesh while incorporating lithium chloride, and a binary solvent achieves antifreezing and antidehydration characteristics. The design minimizes flexural rigidity, resulting in high interfacial adhesion energy with human skin, and enhances gas (air, oxygen, and carbon dioxide) permeance and water vapor transmission rate. Consequently, the ultrathin hydrogel electrode exhibits high biocompatibility, superior wear comfort, and minimized motion and sweat artifacts, enabling reliable, uninterrupted, wireless health monitoring over eight consecutive days across various real-life activities and adaptation to cold environments.
- Top Cited PapersOpen Access
- 12 January 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (2) , eadj5389
A 10-micrometer-thick nanomesh-reinforced gas-permeable hydrogel skin sensor for long-term electrophysiological monitoring
Hydrogel-enabled skin bioelectronics that can continuously monitor health for extended periods is crucial for early disease detection and treatment. However, it is challenging to engineer ultrathin gas-permeable hydrogel sensors that can self-adhere to the human skin for long-term daily use (>1 week). Here, we present a ~10-micrometer-thick polyurethane nanomesh–reinforced gas-permeable hydrogel sensor that can self-adhere to the human skin for continuous and high-quality electrophysiological monitoring for 8 days under daily life conditions. This research involves two key steps: (i) material design by gelatin-based thermal-dependent phase change hydrogels and (ii) robust thinness geometry achieved through nanomesh reinforcement. The resulting ultrathin hydrogels exhibit a thickness of ~10 micrometers with superior mechanical robustness, high skin adhesion, gas permeability, and anti-drying performance. To highlight the potential applications in early disease detection and treatment that leverage the collective features, we demonstrate the use of ultrathin gas-permeable hydrogels for long-term, continuous high-precision electrophysiological monitoring under daily life conditions up to 8 days.
- 12 January 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (2) , eadj5389
Top Cited PapersOpen AccessA 10-micrometer-thick nanomesh-reinforced gas-permeable hydrogel skin sensor for long-term electrophysiological monitoring
Hydrogel-enabled skin bioelectronics that can continuously monitor health for extended periods is crucial for early disease detection and treatment. However, it is challenging to engineer ultrathin gas-permeable hydrogel sensors that can self-adhere to the human skin for long-term daily use (>1 week). Here, we present a ~10-micrometer-thick polyurethane nanomesh–reinforced gas-permeable hydrogel sensor that can self-adhere to the human skin for continuous and high-quality electrophysiological monitoring for 8 days under daily life conditions. This research involves two key steps: (i) material design by gelatin-based thermal-dependent phase change hydrogels and (ii) robust thinness geometry achieved through nanomesh reinforcement. The resulting ultrathin hydrogels exhibit a thickness of ~10 micrometers with superior mechanical robustness, high skin adhesion, gas permeability, and anti-drying performance. To highlight the potential applications in early disease detection and treatment that leverage the collective features, we demonstrate the use of ultrathin gas-permeable hydrogels for long-term, continuous high-precision electrophysiological monitoring under daily life conditions up to 8 days.