Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Augustė Melaikaitė has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Haptic Feedback Reduces Telesurgery Operators’ Reaction Times Compared to Conventional Stimulation: Results of a First-in-Human Study

    by Vaidas Labunskas, Vilius Dambrauskas, Augustė Melaikaitė, Vilhelmas Konstantinas Landsbergis, Radvilė Kadytė, Augustinas Baušys, Tomas Baltrūnas

    This prospective, cross-sectional study evaluated reaction time (RT) variations across different sensory stimuli to investigate the efficacy of haptic feedback (HF) in reducing response latency for telesurgical applications. Three healthy-volunteer age cohorts (18–25, 35–45, and 55–65 years) were tested using visual, auditory, superficial, and deep sensations, alongside a multimodal stimulus combining visual and superficial inputs to simulate HF. The findings revealed that combined visual and superficial stimulation yielded a mean RT of 227 ± 27 ms, outperforming visual-only stimulation by 40 ms (95% CI: 32–48 ms) and superficial-only stimulation by 26 ms (95% CI: 20–33 ms) (p = 0.001). While this performance boost was consistent across all age groups, the 55–65 age cohort demonstrated the most pronounced reduction in RT when the combined stimuli were used. These results suggest that integrating tactile sensations with visual cues significantly mitigates latency compared to unimodal inputs, underscoring the potential of haptic feedback to enhance operator performance and safety in latency-sensitive environments like remote surgery.

  • Open Access

    Validation of the Lithuanian Version of the Walking Impairment Questionnaire in Patients with Peripheral Arterial Disease

    by Tomas Baltrūnas, Karolis Medelis, Augustė Melaikaitė, Austėja Račytė, Gabija Pikturnaitė, Rokas Baltušnikas, Ieva Laucevičienė, Kęstutis Ručinskas

    Background and Objectives: The Walking Impairment Questionnaire (WIQ) is a short and simple tool to measure walking impairment for patients with peripheral arterial disease requiring no special equipment or trained staff. The aim of this study was to assess the validity and reliability of the culturally adapted Lithuanian WIQ version in patients with intermittent claudication. Materials and Methods: In total, 40 patients with intermittent claudication and ankle–brachial index < 0.90 participated in this study. Reliability and internal consistency of the questionnaire were assessed by the intra-class correlation coefficient (ICC) and Cronbach’s alpha (α), respectively. Validity was determined by correlations between the WIQ scores and a subjective test (Quality of Life 5 Dimension Questionnaire 3 Level Version (EQ-5D-3L)) and objective tests (6 min walk test (6MWT), treadmill test, and ankle–brachial index). Results: The test–retest reliability was assessed as excellent with an intraclass correlation coefficient of 0.90. The values of Cronbach’s alpha were 0.957 (I time) and 0.948 (II time) and indicated an excellent internal consistency. Statistically significant Spearman correlations were detected between the WIQ and walking distances on the 6MWT (rho 0.514, p < 0.001) and treadmill test (rho 0.515, p < 0.001). Higher WIQ scores were associated with longer walking distances and duration. Moderate negative and low negative correlations were found between the WIQ and EQ-5D-3L scores. Conclusions: The Lithuanian version of culturally adapted WIQ demonstrates reliability and validity for patients with intermittent claudication, supported by two different walking tests showing statistically significant moderate Spearman correlations.