RGRadu Gavrilescu

Radu Gavrilescu

*This is an algorithmically generated author record based on publicly available information.

Radu Gavrilescu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mid-Term Impact of Conduction System Pacing on Overall Cardiac Performance: A Non-Randomized, Prospective, Single-Center Echocardiographic Study

    by Catalin Pestrea, Ecaterina Cicala, Roxana Enache, Marcela Rusu, Radu Gavrilescu, Adrian Vaduva, Madalina Ivascu, Florin Ortan, Dana Pop

    Introduction. Recently published data suggested significantly lower pacing-induced cardiomyopathy (PICM) incidence with conduction system pacing (CSP). Because most data evaluated only the impact on the left ventricle, this study aimed to assess changes in echocardiographic parameters of morphology and function for all heart chambers in patients with baseline preserved and mid-range LVEF over a medium-term follow-up period after CSP. Methods. A total of 128 consecutive patients with LVEF > 40% and successful CSP for bradyarrhythmic indication were prospectively enrolled. A complete 2D echocardiographic examination was performed at baseline and the last follow-up. Results. In total, 38 patients received His bundle pacing (HBP) and 90 received left bundle branch area pacing (LBBAP). The mean follow-up period was 699.2 ± 177.2 days, with 23 patients lost during this period. The ventricular pacing burden for the entire group was 97.2 ± 4.2%. Only three patients (2.9%) met the criteria for PICM. CSP led to a significant increase in LVEF (from 54.2 ± 7.9 to 56.7 ± 7.8%, p = 0.01) and a significant decrease in LV diastolic (from 107.2 ± 41.8 to 91.3 ± 41.8 mL, p < 0.001) and systolic (from 49.7 ± 21.4 to 39.5 ± 18.2 mL, p < 0.001) volumes. There were no significant changes in E/e′, mitral regurgitation, atrial volumes, and right ventricle (RV) diameter. There was a significant improvement in RV function. Tricuspid regurgitation was the only parameter that worsened. There were no differences in evolution for each echocardiographic parameter between the HBP and the LBBAP groups. Conclusions. HBP and LBBAP are equally protective for harmful changes in both atria and ventricles. The prevalence of PICM, defined as a decrease in LVEF, is very low with CSP.


  • Open Access

    Feasibility of Conduction System Pacing in Patients with Baseline Bundle Branch Block—A Single-Center Mid-Term Follow-Up Study

    by Catalin Pestrea, Marcela Rusu, Roxana Enache, Ecaterina Cicala, Radu Gavrilescu, Adrian Vaduva, Florin Ortan, Corneliu Iorgulescu, Radu Vatasescu

    Background: The primary prerequisite for a successful conduction system pacing (CSP) procedure is the integrity of the conduction system, which may be impaired if a baseline bundle branch block (BBB) is present. This study aimed to evaluate the feasibility and mid-term performance of permanent CSP in patients with baseline BBB and to compare the results between left bundle branch block (LBBB) and right bundle branch block (RBBB) patterns. Material and methods: A total of 101 patients with typical BBB and an attempt at CSP were retrospectively reviewed. Procedural characteristics, pacing, sensing parameters, and complications at baseline and after a mid-term follow-up were analyzed. Results: The global procedural success for CSP was 93%. His bundle pacing (HBP) had a significantly lower success rate than left bundle branch area pacing (LBBAP) (50.5% vs. 86%). The paced QRS duration was significantly narrower with HBP. The pacing and sensing thresholds were significantly better with LBBAP. Procedural complications occurred only in the LBBAP group (two acute perforations in the LV cavity and one acute chest pain during lead fixation) without long-term sequelae. The HBP and the LBBAP procedural success rates were higher in the RBBB versus the LBBB group (62.5% vs. 44.9% and 100% vs. 81.5%, respectively). Baseline QRS duration, atrial volumes, and right ventricular diameters were significantly associated with HBP procedural failure. The follow-up pacing and sensing thresholds were similar to the baseline values for all pacing methods and BBB morphology. Only one device-related complication leading to pacing interruption was recorded. Conclusion: In patients with bundle branch blocks, CSP is a feasible procedure associated with a high success rate, stable pacing and sensing parameters, and low complication rates over a mid-term follow-up.