Yang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yang Liu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Mingjian Sun
Harbin Institute of Technology
2 shared publications - Baiya Li
Department of Otolaryngology Head and Neck Surgery, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, China
1 shared publication - Boheng Zhang
Harbin Institute of Technology
1 shared publication - Cailing Lin
Harbin Institute of Technology
1 shared publication - Gang Li
School of Astronautics, Harbin Institute of Technology, Harbin 150000, P. R. China
1 shared publication - Haorui Huang
Harbin Institute of Technology
1 shared publication
Latest Publications
- 15 April 2026
- Published by Elsevier in Neural Networks
- Vol. 202, 108994
FDPMambaFuse: A frequency-domain and parallel Mamba-based model for multimodal medical image fusion
- 15 April 2026
- Published by Elsevier in Neural Networks
- Vol. 202, 108994
FDPMambaFuse: A frequency-domain and parallel Mamba-based model for multimodal medical image fusion
- Open Access
- 12 January 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 17 (03)
Photoacoustic elastography based on laser-excited shear wave
Elastography can be used as a diagnostic method for quantitative characterization of tissue hardness information and thus, differential changes in pathophysiological states of tissues. In this study, we propose a new method for shear wave elastography (SWE) based on laser-excited shear wave, called photoacoustic shear wave elastography (PASWE), which combines photoacoustic (PA) technology with ultrafast ultrasound imaging. By using a focused laser to excite shear waves and ultrafast ultrasonic imaging for detection, high-frequency excitation of shear waves and noncontact elastic imaging can be realized. The laser can stimulate the tissue with the light absorption characteristic to produce the thermal expansion, thus producing the shear wave. The frequency of shear wave induced by laser is higher and the frequency band is wider. By tracking the propagation of shear wave, Young’s modulus of tissue is reconstructed in the whole shear wave propagation region to further evaluate the elastic information of tissue. The feasibility of the method is verified by experiments. Compared with the experimental results of supersonic shear imaging (SSI), it is proved that the method can be used for quantitative elastic imaging of the phantoms. In addition, compared with the SSI method, this method can realize the noncontact excitation of the shear wave, and the frequency of the shear wave excited by the laser is higher than that of the acoustic radiation force (ARF), so the spatial resolution is higher. Compared to the traditional PA elastic imaging method, this method can obtain a larger imaging depth under the premise of ensuring the imaging resolution, and it has potential application value in the clinical diagnosis of diseases requiring noncontact quantitative elasticity.
- 12 January 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 17 (03)
Open AccessPhotoacoustic elastography based on laser-excited shear wave
Elastography can be used as a diagnostic method for quantitative characterization of tissue hardness information and thus, differential changes in pathophysiological states of tissues. In this study, we propose a new method for shear wave elastography (SWE) based on laser-excited shear wave, called photoacoustic shear wave elastography (PASWE), which combines photoacoustic (PA) technology with ultrafast ultrasound imaging. By using a focused laser to excite shear waves and ultrafast ultrasonic imaging for detection, high-frequency excitation of shear waves and noncontact elastic imaging can be realized. The laser can stimulate the tissue with the light absorption characteristic to produce the thermal expansion, thus producing the shear wave. The frequency of shear wave induced by laser is higher and the frequency band is wider. By tracking the propagation of shear wave, Young’s modulus of tissue is reconstructed in the whole shear wave propagation region to further evaluate the elastic information of tissue. The feasibility of the method is verified by experiments. Compared with the experimental results of supersonic shear imaging (SSI), it is proved that the method can be used for quantitative elastic imaging of the phantoms. In addition, compared with the SSI method, this method can realize the noncontact excitation of the shear wave, and the frequency of the shear wave excited by the laser is higher than that of the acoustic radiation force (ARF), so the spatial resolution is higher. Compared to the traditional PA elastic imaging method, this method can obtain a larger imaging depth under the premise of ensuring the imaging resolution, and it has potential application value in the clinical diagnosis of diseases requiring noncontact quantitative elasticity.