Mirosław Łuniewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Mirosław Łuniewski has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Gerwin Hoogsteen
Computer Architecture for Embedded Systems, University of Twente, Enschede, Overijssel, Netherlands
1 shared publication - Marcin Bugaj
Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Nowowiejska 24 Str., 00-665 Warsaw, Poland
1 shared publication - Patryk Chaja
Institute of Fluid Flow Machinery, Polish Academy of Sciences, Fiszera 14, 80-231 Gdansk, Poland
1 shared publication - Sebastian Bykuć
Institute of Fluid Flow Machinery, Polish Academy of Sciences, 80-231 Gdańsk, Poland
1 shared publication - Weronika Radziszewska
Systems Research Institute, Polish Academy of Sciences, Newelska 6, 01-447 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 7 March 2022
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 70 (2) , 140690
Testing of a price-based system for power balancing on real-life HVAC installation in real life
HVAC systems use a substantial part of the whole energy usage of buildings. The optimizing of their operation can greatly affect the power use of a building, making them an interesting subject when trying to save energy. However, this should not affect the comfort of the people inside. Many approaches aim to optimize the operation of the heating and cooling system; in this paper, we present an approach to steer the heat pumps to reduce energy usage while aiming to maintain a certain level of comfort. For this purpose, we employ a market-based distributed method for power-balancing. To maintain the comfort level, the market-based distributed system assigns each device a cost-curve, parametrized with the current temperature of the room. This allows the cost to reflect the urgency of the HVAC operation. This approach was tested in a real-world environment: we use 10 heat pumps responsible for temperature control in 10 comparable-sized rooms. The test was performed for 3 months in summer. We limited the total peak power, and the algorithm balanced the consumption of the heat pumps with the available supply. The experiments showed that the system successfully managed to operate within the limit (lowering peak usage), and - to a certain point - reduce the cost without significantly deteriorating the working conditions of the occupants of the rooms. This test allowed us to estimate the minimal peak power requirement for the tested set-up that will still keep the room temperatures in or close to comfortable levels. The experiments show that a fully distributed market-based approach with parametrized cost functions can be used to limit peak usage while maintaining temperatures.
- 7 March 2022
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 70 (2) , 140690
Open AccessTesting of a price-based system for power balancing on real-life HVAC installation in real life
HVAC systems use a substantial part of the whole energy usage of buildings. The optimizing of their operation can greatly affect the power use of a building, making them an interesting subject when trying to save energy. However, this should not affect the comfort of the people inside. Many approaches aim to optimize the operation of the heating and cooling system; in this paper, we present an approach to steer the heat pumps to reduce energy usage while aiming to maintain a certain level of comfort. For this purpose, we employ a market-based distributed method for power-balancing. To maintain the comfort level, the market-based distributed system assigns each device a cost-curve, parametrized with the current temperature of the room. This allows the cost to reflect the urgency of the HVAC operation. This approach was tested in a real-world environment: we use 10 heat pumps responsible for temperature control in 10 comparable-sized rooms. The test was performed for 3 months in summer. We limited the total peak power, and the algorithm balanced the consumption of the heat pumps with the available supply. The experiments showed that the system successfully managed to operate within the limit (lowering peak usage), and - to a certain point - reduce the cost without significantly deteriorating the working conditions of the occupants of the rooms. This test allowed us to estimate the minimal peak power requirement for the tested set-up that will still keep the room temperatures in or close to comfortable levels. The experiments show that a fully distributed market-based approach with parametrized cost functions can be used to limit peak usage while maintaining temperatures.