Han Liu
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Han Liu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Wei Cao
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
2 shared publications - Yang Ge
Shenyang Guoke Bright Medical Technology Co., Ltd., Shenyang 110170, China
2 shared publications - Yi Liu
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
2 shared publications - Yongtong Feng
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
2 shared publications - Fengxin Shi
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
1 shared publication - Hong Zhou
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
1 shared publication
Latest Publications
- Open Access
- 7 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (3) , 366
Single-Ended Eddy Current Micro-Displacement Sensor with High Precision Based on Temperature Compensation
To measure the micro-displacement reliably with high precision, a single-ended eddy current sensor based on temperature compensation was studied in detail. At first, the principle of the eddy current sensor was introduced, and the manufacturing method of the probe was given. The overall design plan for the processing circuit was induced by analyzing the characteristics of the probe output signal. The variation in the probe output signal was converted to pulses with different widths, and then it was introduced to the digital phase discriminator along with a reference signal. The output from the digital phase discriminator was processed by a low-pass filter to obtain the DC component. At last, the signal was amplified and compensated to reduce the influence of temperature. The selection criteria of the frequency of the exciting signal and the design of the signal conditioning circuit were described in detail, as well as the design of the temperature-compensating circuit based on the digital potentiometer with an embedded temperature sensor. Finally, an experimental setup was constructed to test the sensor, and the results were given. The results show that nonlinearity exists in the single-ended eddy current sensor with a large range. When the range is 500 μm, the resolution can reach 46 nm, and the repeatability error is ±0.70% FR. Within the temperature range from +2 °C to +58 °C, the voltage fluctuation in the sensor is reduced to 44 mV after temperature compensation compared to the value of 586 mV before compensation. The proposed plan is verified to be feasible, and the measuring range, precision, and target material should be considered in real-world applications.
- 7 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (3) , 366
Open AccessSingle-Ended Eddy Current Micro-Displacement Sensor with High Precision Based on Temperature Compensation
To measure the micro-displacement reliably with high precision, a single-ended eddy current sensor based on temperature compensation was studied in detail. At first, the principle of the eddy current sensor was introduced, and the manufacturing method of the probe was given. The overall design plan for the processing circuit was induced by analyzing the characteristics of the probe output signal. The variation in the probe output signal was converted to pulses with different widths, and then it was introduced to the digital phase discriminator along with a reference signal. The output from the digital phase discriminator was processed by a low-pass filter to obtain the DC component. At last, the signal was amplified and compensated to reduce the influence of temperature. The selection criteria of the frequency of the exciting signal and the design of the signal conditioning circuit were described in detail, as well as the design of the temperature-compensating circuit based on the digital potentiometer with an embedded temperature sensor. Finally, an experimental setup was constructed to test the sensor, and the results were given. The results show that nonlinearity exists in the single-ended eddy current sensor with a large range. When the range is 500 μm, the resolution can reach 46 nm, and the repeatability error is ±0.70% FR. Within the temperature range from +2 °C to +58 °C, the voltage fluctuation in the sensor is reduced to 44 mV after temperature compensation compared to the value of 586 mV before compensation. The proposed plan is verified to be feasible, and the measuring range, precision, and target material should be considered in real-world applications.
- Open Access
- 16 January 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (2) , 1081
High-Voltage Electrostatic Field Hydrogel Microsphere 3D Culture System Improves Viability and Liver-like Properties of HepG2 Cells
Three-dimensional (3D) hepatocyte models have become a research hotspot for evaluating drug metabolism and hepatotoxicity. Compared to two-dimensional (2D) cultures, 3D cultures are better at mimicking the morphology and microenvironment of hepatocytes in vivo. However, commonly used 3D culture techniques are not suitable for high-throughput drug screening (HTS) due to their high cost, complex handling, and inability to simulate cell–extracellular matrix (ECM) interactions. This article describes a method for rapid and reproducible 3D cell cultures with ECM–cell interactions based on 3D culture instrumentation to provide more efficient HTS. We developed a microsphere preparation based on a high-voltage electrostatic (HVE) field and used sodium alginate- and collagen-based hydrogels as scaffolds for 3D cultures of HepG2 cells. The microsphere-generating device enables the rapid and reproducible preparation of bioactive hydrogel microspheres. This 3D culture system exhibited better cell viability, heterogeneity, and drug-metabolizing activity than 2D and other 3D culture models, and the long-term culture characteristics of this system make it suitable for predicting long-term liver toxicity. This system improves the overall applicability of HepG2 spheroids in safety assessment studies, and this simple and controllable high-throughput-compatible method shows potential for use in drug toxicity screening assays and mechanistic studies.
- 16 January 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (2) , 1081
Open AccessHigh-Voltage Electrostatic Field Hydrogel Microsphere 3D Culture System Improves Viability and Liver-like Properties of HepG2 Cells
Three-dimensional (3D) hepatocyte models have become a research hotspot for evaluating drug metabolism and hepatotoxicity. Compared to two-dimensional (2D) cultures, 3D cultures are better at mimicking the morphology and microenvironment of hepatocytes in vivo. However, commonly used 3D culture techniques are not suitable for high-throughput drug screening (HTS) due to their high cost, complex handling, and inability to simulate cell–extracellular matrix (ECM) interactions. This article describes a method for rapid and reproducible 3D cell cultures with ECM–cell interactions based on 3D culture instrumentation to provide more efficient HTS. We developed a microsphere preparation based on a high-voltage electrostatic (HVE) field and used sodium alginate- and collagen-based hydrogels as scaffolds for 3D cultures of HepG2 cells. The microsphere-generating device enables the rapid and reproducible preparation of bioactive hydrogel microspheres. This 3D culture system exhibited better cell viability, heterogeneity, and drug-metabolizing activity than 2D and other 3D culture models, and the long-term culture characteristics of this system make it suitable for predicting long-term liver toxicity. This system improves the overall applicability of HepG2 spheroids in safety assessment studies, and this simple and controllable high-throughput-compatible method shows potential for use in drug toxicity screening assays and mechanistic studies.