HLHan Liu

Han Liu

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Han Liu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single-Ended Eddy Current Micro-Displacement Sensor with High Precision Based on Temperature Compensation

    by Zhengping Xu, Yongtong Feng, Yi Liu, Fengxin Shi, Yang Ge, Han Liu, Wei Cao, Hong Zhou, Shuang Geng, Wenqi Lin

    To measure the micro-displacement reliably with high precision, a single-ended eddy current sensor based on temperature compensation was studied in detail. At first, the principle of the eddy current sensor was introduced, and the manufacturing method of the probe was given. The overall design plan for the processing circuit was induced by analyzing the characteristics of the probe output signal. The variation in the probe output signal was converted to pulses with different widths, and then it was introduced to the digital phase discriminator along with a reference signal. The output from the digital phase discriminator was processed by a low-pass filter to obtain the DC component. At last, the signal was amplified and compensated to reduce the influence of temperature. The selection criteria of the frequency of the exciting signal and the design of the signal conditioning circuit were described in detail, as well as the design of the temperature-compensating circuit based on the digital potentiometer with an embedded temperature sensor. Finally, an experimental setup was constructed to test the sensor, and the results were given. The results show that nonlinearity exists in the single-ended eddy current sensor with a large range. When the range is 500 μm, the resolution can reach 46 nm, and the repeatability error is ±0.70% FR. Within the temperature range from +2 °C to +58 °C, the voltage fluctuation in the sensor is reduced to 44 mV after temperature compensation compared to the value of 586 mV before compensation. The proposed plan is verified to be feasible, and the measuring range, precision, and target material should be considered in real-world applications.


  • Open Access

    High-Voltage Electrostatic Field Hydrogel Microsphere 3D Culture System Improves Viability and Liver-like Properties of HepG2 Cells

    by Yi Liu, Yang Ge, Yanfan Wu, Yongtong Feng, Han Liu, Wei Cao, Jinsong Xie, Jingzhong Zhang

    Three-dimensional (3D) hepatocyte models have become a research hotspot for evaluating drug metabolism and hepatotoxicity. Compared to two-dimensional (2D) cultures, 3D cultures are better at mimicking the morphology and microenvironment of hepatocytes in vivo. However, commonly used 3D culture techniques are not suitable for high-throughput drug screening (HTS) due to their high cost, complex handling, and inability to simulate cell–extracellular matrix (ECM) interactions. This article describes a method for rapid and reproducible 3D cell cultures with ECM–cell interactions based on 3D culture instrumentation to provide more efficient HTS. We developed a microsphere preparation based on a high-voltage electrostatic (HVE) field and used sodium alginate- and collagen-based hydrogels as scaffolds for 3D cultures of HepG2 cells. The microsphere-generating device enables the rapid and reproducible preparation of bioactive hydrogel microspheres. This 3D culture system exhibited better cell viability, heterogeneity, and drug-metabolizing activity than 2D and other 3D culture models, and the long-term culture characteristics of this system make it suitable for predicting long-term liver toxicity. This system improves the overall applicability of HepG2 spheroids in safety assessment studies, and this simple and controllable high-throughput-compatible method shows potential for use in drug toxicity screening assays and mechanistic studies.