ABAnhelina Bilokon

Anhelina Bilokon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anhelina Bilokon has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Low-frequency interaural time differences are resistant to across-frequency binaural interference across a range of overall levels

    by Anhelina Bilokon, Allison Choi, Matthew J. Goupell

    Low-frequency interaural time differences (ITDs) are the primary human horizontal-plane localization cue. Across-frequency binaural interference tasks, which assess changes in ITD sensitivity in the presence of a remote interferer, reveal how listeners weigh binaural information across frequency regions. Low-frequency (0.5-kHz) targets experience less interference from high-frequency (4-kHz) interferers compared to the reverse, but the role of relative signal level across frequencies remains relatively underexplored. This study measured ITD discrimination thresholds in ten young normal-hearing listeners using target and interferer frequencies of 0.5, 4, and 8 kHz and levels of 35, 55, and 75 dB-A. Binaural interference magnitude depended on both stimulus level and frequency. For a 4-kHz target and 0.5-kHz interferer, interference significantly increased with increasing interferer and decreasing target levels. For a 0.5-kHz target and 4-kHz interferer, interference significantly increased with increasing interferer level when the target level was 35 dB-A, but was unchanged when the target level was 55 or 75 dB-A. The resistance to binaural interference for the low-frequency target at higher target levels confirms the robustness of low-frequency ITD processing and highlights the level-dependent vulnerability of high-frequency targets to interference. This helps advance understanding of spatial hearing for complex stimuli in more realistic auditory scenes.

  • The Rapid Decline in Interaural-Time-Difference Sensitivity for Pure Tones Can Be Explained by Peripheral Filtering

    by Matthew J. Goupell, G. Christopher Stecker, Brittany T. Williams, Anhelina Bilokon, Daniel J. Tollin

    Purpose The interaural time difference (ITD) is a primary horizontal-plane sound localization cue computed in the auditory brainstem. ITDs are accessible in the temporal fine structure of pure tones with a frequency of no higher than about 1400 Hz. How listeners’ ITD sensitivity transitions from very best sensitivity near 700 Hz to impossible to detect within 1 octave currently lacks a fully compelling physiological explanation. Here, it was hypothesized that the rapid decline in ITD sensitivity is dictated not by a central neural limitation but by initial peripheral sound encoding, specifically, the low-frequency (apical) portion of the cochlear excitation pattern produced by a pure tone. Methods ITD sensitivity was measured in 16 normal-hearing listeners as a joint function of frequency (900–1500 Hz) and level (10–50 dB sensation level). Results Performance decreased with increasing frequency and decreasing sound level. The slope of performance decline was 90 dB/octave, consistent with the low-frequency slope of the cochlear excitation pattern. Conclusion Fine-structure ITD sensitivity near 1400 Hz may be conveyed primarily by “off-frequency” activation of neurons tuned to lower frequencies near 700 Hz. Physiologically, this could be realized by having neurons sensitive to fine-structure ITD up to only about 700 Hz. A more extreme model would have only a single narrow channel near 700 Hz that conveys fine-structure ITDs. Such a model is a major simplification and departure from the classic formulation of the binaural display, which consists of a matrix of neurons tuned to a wide range of relevant frequencies and ITDs.


  • Open Access

    The rapid decline in interaural-time-difference sensitivity for pure tones can be explained by peripheral filtering

    by Matthew J. Goupell, G. Christopher Stecker, Brittany T. Williams, Anhelina Bilokon, Daniel J. Tollin

    Purpose: The interaural time difference (ITD) is a primary horizontal-plane sound localization cue computed in the auditory brainstem. ITDs are accessible in the temporal fine structure of pure tones with a frequency of no higher than about 1400 Hz. Explaining how listeners’ ITD sensitivity transitions from very best sensitivity near 700 Hz to impossible to detect within 1 octave currently lacks a fully compelling physiological explanation. Here, it was hypothesized that the rapid decline in ITD sensitivity is dictated not by a central neural limitation but by initial peripheral sound encoding, specifically, the low-frequency (apical) edge of the cochlear excitation pattern produced by a pure tone. Methods: ITD sensitivity was measured in 16 normal-hearing listeners as a joint function of frequency (900-1500 Hz) and level (10-50 dB sensation level). Results: Performance decreased with increasing frequency and decreasing sound level. The slope of performance decline was 90 dB/octave, consistent with the low-frequency slope of the cochlear excitation pattern. Conclusion: Fine-structure ITD sensitivity near 1400 Hz may be conveyed primarily by “off-frequency” activation of neurons tuned to lower frequencies near 700 Hz. Physiologically, this could be realized by having neurons sensitive to fine-structure ITD up to only about 700 Hz. A more extreme model would have only a single narrow channel near 700 Hz that conveys fine-structure ITDs. Such a model is a major simplification and departure from the classic formulation of the binaural display, which consists of a matrix of neurons tuned to a wide range of relevant frequencies and ITDs.