Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Muzi Zhang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Estimation of the Maximum Plane Positioning Error of Deep Submersibles Based on Underwater Virtual Reference Points

    by Wenlong Gao, Yongfu Sun, Yibin Li, Muzi Zhang, Yue Zhang, Yixu Liu, Yinghao Zhuang, Yan Song

    Integrated navigation is widely used for the navigation and positioning of submersibles. However, in deep-sea environments, the inability to obtain Global Navigation Satellite System signals and the lack of precise underwater reference points on the seabed make it challenging to quickly and cost-effectively estimate the maximum plane positioning error (MPPE) of the ultra short baseline (USBL)-assisted integrated navigation system at a 95$\%$ confidence level. This article proposes a method for estimating the MPPE of integrated navigation coordinates based on underwater virtual reference points. This method introduces underwater virtual reference points and derives analytical expressions for error bounds using vector representation and the Cauchy–Schwarz inequality, then calculates the MPPE for integrated navigation coordinates at a 95$\%$ confidence level by sorting the upper and lower bounds of horizontal error in ascending order. Experimental results indicate that for submersibles operating at an average slant range of 4201 m, the MPPE for strapdown inertial navigation system/USBL integrated navigation coordinates is 11.74 m, representing 0.76$\%$ of the submersible's range. The use of long baseline positioning values as ground truth validates the accuracy of these estimation results. The proposed method for estimating the MPPE of integrated navigation coordinates requires only speed, heading, attitude, and USBL positioning data, thereby eliminating the need for specialized positioning error estimation experiments. This offers a more convenient, rapid, and cost-effective solution. Estimating the MPPE provides significant reference for determining the submersible's positioning errors during marine environmental data collection and establishing the coordinate range of important underwater targets.

  • Study of the Advantages of Commercial Phone Camera for Measuring the Salinity of Seawater

    by Juan Su, Shiyu Chen, Cong Zhang, Xiaoxue Bai, Muzi Zhang, Chi Wu

    The optical refractive index reflects all substances dissolved in seawater. In contrast to conductivity, which can only sense the ionized components of seawater, it is one of the ideal parameters for assessing the absolute salinity of seawater. However, existing methods for measuring seawater absolute salinity based on refractive index still face challenges in balancing the measuring interval ([1.329, 1.348] Refractive Index Unit (RIU)) and resolution (10-7 RIU) to meet the needs of seawater measurement. To address this issue and promote the widespread application of seawater absolute salinity measurement, we propose an innovative system that utilizes the Complementary Metal–Oxide–Semiconductor (CMOS) camera module (CCM) in commercial smartphones as a position sensor. By measuring the position change of light emitted from a V–shaped groove, the system determines the refractive index and salinity of seawater. Experimental results show that the system, combined with an optimized gray centroid algorithm, achieves a resolution of 0.3 pixels, resulting in a refractive index resolution of 3.3×10-7 and a practical salinity resolution of 0.0018, with up to 36,666 measurement point. Compared to traditional Position–Sensitive Devices (PSDs), the system’s resolution is improved by 1.45 times, and the number of measurement points is increased by 9.16 times. Further comparative experiments demonstrate that the position measurement standard deviation of the CCM is unaffected by the light spot position, while the standard deviation the PSD measurements depends on the distance between the spot and the center position, which is unfavorable for subsequent data calibration. Moreover, repeatability and stability tests and uncertainty analysis show that using the CCM as a position sensor for measuring seawater refractive index and salinity exhibits excellent stability and repeatability. The smartphone CCM offers diverse options, compact size, low cost and fast development advantages, providing new possibilities for achieving high–resolution and wide–range seawater refractive index and salinity measurement.

  • Calibration of NTC Thermistor-Based Marine Temperature Instruments With Sub-mK Accuracy

    by Dexin Gao, Zhigang Qiao, Muzi Zhang, Qingquan Sun, Jiali Wu, Juan Su, Wenyue Gao, Chi Wu

    Accurate ocean temperature measurement is critical for climate studies and ocean circulation modeling. Thermistor-based sensors, valued for high sensitivity and stability, require precise calibration due to their nonlinear resistance-temperature relationship. We evaluated six calibration equations (Basic, Hoge-1–4, S&H) across 273.15–308.15 K, and compared performance at calibration and non-calibration points. Furthermore, a novel temperature-distribution-optimized calibration strategy was proposed to enhance efficiency. Results showed that higher-order equations (Hoge-2, Hoge-3, Hoge-4, S&H) achieved sub-mK residuals with 13 calibration points, while lower-order equations failed. Extrapolation errors remained <1 mK within 2 K. With minimal calibration points, Hoge-2, Hoge-4, and S&H maintained <0.1 mK residuals at calibration points but exhibited increased residuals (~0.5 – 1 mK) in low-temperature non-calibration regions. The proposed strategy paired with the Hoge-2 equation reduced calibration time/cost by 50% compared to traditional 5 K-interval methods, without compromising accuracy. This work advances high-precision ocean temperature sensing, offering insights for in-situ calibration and climate model refinement.


  • A High-Sensitivity Pressure Sensor Based on Optical Fabry–Pérot Cavities for Extreme Deep-Sea Applications

    by Muzi Zhang, Xin Wang, Xiaoxue Bai, Chi Wu

    This paper presents a novel optical Fabry-Pérot (FP) interferometric pressure sensor with an extensive measurement range, specifically designed for the high-pressure and high-salinity conditions of the ocean. Utilizing ultra-high-precision demodulation techniques, the sensor adeptly captures minute structural deformations, significantly reducing material fatigue and enhancing overall sensitivity. It demonstrates exceptional performance features, including superior repeatability, excellent linearity over a wide measurement spectrum, and significant scalability—attributes crucial for diverse pressure measurement applications. Optimized for fatigue resistance and stability over extended operational periods, the sensor is positioned as an ideal tool for deep-sea exploration and as a critical tool for multi-parameter optical sensing integration. Additionally, an improved simulation model was developed to include processing and analysis errors, enhancing the system’s predictive accuracy under varied environmental conditions. We describe the working principles of the sensor and present both theoretical analyses and standard experimental comparisons. The experimental results highlight the sensor’s accuracy, long-term stability, expansive measurement capacity, and strong environmental adaptability. Key performance indicators include a dual-range sensitivity of 0.125 pm/bar within the 0–400 bar range and 0.066 pm/bar from 400 to 1200 bar, a pressure resolution of 0.75 bar (0.063% F.S.), and an Allan variance of 1.12 × 10−11 nm under a 1000 bar load. Based on the experimental results, an online calibration method for optical measurement chamber length based on Free Spectral Range (FSR) is proposed, addressing the identified measurement challenges and offering constructive insights to improve the adaptability of marine optical sensors to environmental conditions.


  • High-Resolution Seawater Density Sensor Based on Michelson Interferometer

    by Xiaoxue Bai, Xin Wang, Muzi Zhang, Shanshan Zhao, Mengzhen Wang, Shiyu Chen, Juan Su, Chi Wu

    A novel seawater density sensor has been developed, offering high resolution and improved accuracy. The sensor employs a Michelson interferometer as the core sensing element, measuring density by directly incorporating seawater samples into the measurement path. To enhance measurement precision, standard seawater is used in the reference path to mitigate temperature and dispersion effects. The sensor system consists of a superluminescent diode and an interrogator, forming a compact, high-sampling-rate wavelength demodulation system that is particularly suitable for measuring seawater density with high spatiotemporal variability. However, the spectrum collected by the interrogator suffers from discontinuity. To address this issue, we designed a high precision multi wavelength demodulation algorithm. This algorithm not only analyzes the movement of each resonance peak with a resolution of 0.0008 nm within a 70nm detection range, but also enables continuous tracking of specific resonance peaks via a dynamic adjustment mechanism. It overcomes the measurement range constraints typically faced by interference-based sensors, which are limited to a single free spectral range. Experimental validations demonstrate the sensor’s capability, achieving a density resolution of 1.79×10 -5 kg/m 3 and an extended measurement range exceeding 35 kg/m 3 . The sensor’s average relative error in density measurement is 0.0144%, highlighting its effectiveness and potential for advanced oceanographic research.


  • Open Access

    In Situ Measurement of Deep-Sea Salinity Using Optical Salinometer Based on Michelson Interferometer

    by Shuqing Yang, Jie Xu, Lanting Ji, Qingquan Sun, Muzi Zhang, Shanshan Zhao, Chi Wu

    Ocean salinity plays an important role in oceanographic research as one of the fundamental parameters. An optical salinometer based on the Michelson interferometer (MI) suitable for in situ measurement in deep-sea environments is proposed in this work, and it features real-time calibration and multichannel multiplexing using the frequency modulated continuous wave (FMCW) technique. The symmetrical sapphire structure used to withstand deep-sea pressure can not only achieve automatic temperature compensation, but also counteract the changes in optical path length under deep-sea pressure. A model formula suitable for optical salinity demodulation is proposed through the nonlinear least squares fitting method. In vertical profile testing, the optical salinometer demonstrated remarkable tracking performance, achieving an error of less than 0.001 psu. The sensor displays a stable salinity demodulation error within ±0.002 psu during a three-month long-term test at a depth of 4000 m. High stability and resolution make this optical salinometer have broad development prospects in ocean observation.


  • High-Resolution Seawater Salinity Sensor Based on Temperature Self-Compensating Optical Interferometer

    by Xin Wang, Xiaoxue Bai, Muzi Zhang, Chi Wu

    A high-resolution seawater salinity sensor, based on a temperature self-compensating resonator, has been developed, which accommodates simultaneous temperature variations in both the reference and sensing arms. The impact of external temperature fluctuations on the optical components affecting the optical path difference is significantly reduced and a salinity sensitivity of 145 pm/PSU and a salinity resolution of 0.0003 PSU are achieved. The sensor utilizes a structure that converts optical rays to spatial light, achieving non-contact measurements which is potentially pivotal for various applications in oceanography and marine studies.


  • Open Access

    Extensible LED-Induced Integrated Fluorescence Detection Module for Quantitative Analysis of Lucigenin Concentration

    by Xiaoguang Qi, Xianglong Hao, Muzi Zhang, Lili Jiang, Wenyue Gao, Chi Wu

    We developed an extensible LED-induced fluorescence detection module with a highly integrated and ultra-compact structure. A target-oriented design methodology was used to demonstrate the module’s optimal design. Lucigenin solution was used as a test sample in evaluation trials to demonstrate the module’s quantitative fluorescence detection capability. Results showed that the integrated module has an outstanding linear response in the range of 0–1 μmol·L−1, with sensitivity and limit of detection (LOD) of 0.1692 V/μmol·L−1 and 0.03 μmol·L−1, respectively. Statistical analyses showed that our integrated module has extremely high repeatability and accuracy, i.e., the values of Pearson’s correlation coefficient and root-mean-square error exceeded 0.9995 and 1.8‰, respectively. More importantly, the integrated module possesses favorable extensibility and can realize on-demand rapid fluorescence-signal detection of other targets using appropriate parameter combinations. This module offers new opportunities for reliable, cost-effective and easy-to-use fluorescence-signal detection, especially in resource-constrained fluorescence detection applications.