Shikai Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shikai Liang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Chuhan Jiang
Department of Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
5 shared publications Haoyu Zhu
Department of Neurosurgery, Peking University First Hospital, Beijing, China
4 shared publicationsJiarui Zhang
Department of Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
3 shared publicationsLian Liu
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
3 shared publicationsXiguang Fu
Department of Neurosurgery, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China
3 shared publicationsYupeng Zhang
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
3 shared publications
Latest Publications
- 12 June 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (4) , 1126-1132
The Lattice flow diverter for the treatment of intracranial aneurysms: a single center experience in 117 consecutive aneurysms
Background Flow diversion has revolutionized the management of intracranial aneurysms. This study aimed to evaluate the preliminary safety and efficacy profile of the novel Lattice flow diverter (LFD) in clinical applications. Methods We retrospectively analyzed consecutive patients with intracranial aneurysms who were treated with the LFD between June 2023 and May 2024. Based on the medical records and imaging data, we collected demographic characteristics, aneurysm features, procedural details, perioperative complications, clinical outcomes, and imaging results. Results This study comprised 105 patients (mean age, 55.4±9.04 years; 72.4% female) with 117 aneurysms, including 104 (88.9%) anterior circulation aneurysms. Procedural success was achieved in all patients (109 devices deployed). Adjunctive techniques included coiling in 39 aneurysms (33.3%) and balloon-assisted wall apposition in three cases (2.6%). The overall perioperative complication rate was 5.8%, with neurological complications (all ischemic events) occurring in 2.9% of cases. Clinical follow-up (mean 10.0±1.4 months) demonstrated preserved functional independence (modified Rankin Scale (mRS) score 0–2) in 98.0% of patients. Imaging follow-up (mean 6.6±1.6 months) revealed complete occlusion in 71.9% of aneurysms and adequate occlusion (Raymond–Roy class I/II) in 88.6%. Conclusion The LFD demonstrated favorable safety and efficacy characteristics for intracranial aneurysm treatment during short-term follow-up. Long-term outcomes require validation in multicenter prospective cohort studies.
- 12 June 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (4) , 1126-1132
The Lattice flow diverter for the treatment of intracranial aneurysms: a single center experience in 117 consecutive aneurysms
Background Flow diversion has revolutionized the management of intracranial aneurysms. This study aimed to evaluate the preliminary safety and efficacy profile of the novel Lattice flow diverter (LFD) in clinical applications. Methods We retrospectively analyzed consecutive patients with intracranial aneurysms who were treated with the LFD between June 2023 and May 2024. Based on the medical records and imaging data, we collected demographic characteristics, aneurysm features, procedural details, perioperative complications, clinical outcomes, and imaging results. Results This study comprised 105 patients (mean age, 55.4±9.04 years; 72.4% female) with 117 aneurysms, including 104 (88.9%) anterior circulation aneurysms. Procedural success was achieved in all patients (109 devices deployed). Adjunctive techniques included coiling in 39 aneurysms (33.3%) and balloon-assisted wall apposition in three cases (2.6%). The overall perioperative complication rate was 5.8%, with neurological complications (all ischemic events) occurring in 2.9% of cases. Clinical follow-up (mean 10.0±1.4 months) demonstrated preserved functional independence (modified Rankin Scale (mRS) score 0–2) in 98.0% of patients. Imaging follow-up (mean 6.6±1.6 months) revealed complete occlusion in 71.9% of aneurysms and adequate occlusion (Raymond–Roy class I/II) in 88.6%. Conclusion The LFD demonstrated favorable safety and efficacy characteristics for intracranial aneurysm treatment during short-term follow-up. Long-term outcomes require validation in multicenter prospective cohort studies.
- 7 April 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (5) , 1263-1272
Pipeline embolization device in treating middle cerebral artery aneurysms: a single-center experience in 69 consecutive patients
Purpose The pipeline embolization device (PED) has been established as an effective treatment option for aneurysms within its designated indications. Recently, its off-label applications, including treating middle cerebral artery (MCA) aneurysms, have increased. This study augmented the current literature by examining the outcomes of PED utilization for MCA aneurysms. Methods We collected data from consecutive patients with MCA aneurysms treated with PED between June 2016 and December 2021. Particularly, we collected data on patient demographics, aneurysm characteristics, procedural details, perioperative complications, and clinical and angiographic follow-up results. Results A total of 69 patients (mean age 47.4 years; 42.0% female) with MCA aneurysms who underwent PED treatment were included in this study. Among these, 5 aneurysms had ruptured previously, and 10 patients had previously undergone open surgery or received endovascular treatment. In the last angiographic follow-up, conducted at a mean of 19.0 ± 13.5 months, 44 of 56 (78.6%) aneurysms achieved complete occlusion. Ten (17.9%) and three (5.4%) patients exhibited in-stent stenosis and MCA occlusion, respectively. During a mean clinical follow-up period of 35.1 months, 10 of 63 patients (15.8%) experienced major procedure-related complications, including 2 hemorrhagic (3.2%) and 8 ischemic (12.7%) events. Conclusion PED is a viable treatment for MCA aneurysms, particularly those with fusiform and wide-necked characteristics that pose challenges for traditional open surgery. PED shows favorable clinical outcomes and occlusion rates and presents a notable risk of complications and in-stent restenosis. Therefore, careful patient selection is crucial when using PEDs to treat MCA aneurysms.
- 7 April 2025
- Published by Springer Nature in Neuroradiology
- Vol. 67 (5) , 1263-1272
Pipeline embolization device in treating middle cerebral artery aneurysms: a single-center experience in 69 consecutive patients
Purpose The pipeline embolization device (PED) has been established as an effective treatment option for aneurysms within its designated indications. Recently, its off-label applications, including treating middle cerebral artery (MCA) aneurysms, have increased. This study augmented the current literature by examining the outcomes of PED utilization for MCA aneurysms. Methods We collected data from consecutive patients with MCA aneurysms treated with PED between June 2016 and December 2021. Particularly, we collected data on patient demographics, aneurysm characteristics, procedural details, perioperative complications, and clinical and angiographic follow-up results. Results A total of 69 patients (mean age 47.4 years; 42.0% female) with MCA aneurysms who underwent PED treatment were included in this study. Among these, 5 aneurysms had ruptured previously, and 10 patients had previously undergone open surgery or received endovascular treatment. In the last angiographic follow-up, conducted at a mean of 19.0 ± 13.5 months, 44 of 56 (78.6%) aneurysms achieved complete occlusion. Ten (17.9%) and three (5.4%) patients exhibited in-stent stenosis and MCA occlusion, respectively. During a mean clinical follow-up period of 35.1 months, 10 of 63 patients (15.8%) experienced major procedure-related complications, including 2 hemorrhagic (3.2%) and 8 ischemic (12.7%) events. Conclusion PED is a viable treatment for MCA aneurysms, particularly those with fusiform and wide-necked characteristics that pose challenges for traditional open surgery. PED shows favorable clinical outcomes and occlusion rates and presents a notable risk of complications and in-stent restenosis. Therefore, careful patient selection is crucial when using PEDs to treat MCA aneurysms.
- 20 October 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (12) , 1215
Rescue techniques for intravascular mechanical obstruction following Woven EndoBridge (WEB) device detachment
The Woven EndoBridge (WEB) device is a well established treatment for bifurcation aneurysms.1–6 However, failed detachment after deployment can present significant challenges. In this technical video (video 1), we report on a patient with a left middle cerebral artery (MCA) bifurcation aneurysm treated with the WEB device. Despite satisfactory deployment, multiple detachment attempts were unsuccessful. After repeated maneuvers, the WEB was finally detached but slightly protruded from the aneurysm sac, compromising blood flow in the superior branch of the MCA. Even after placing an Atlas stent, blood flow was not restored. Ultimately, using a microguidewire and microcatheter, we repositioned the protruded WEB device back into the aneurysm sac, successfully restoring blood flow. This case illustrates that the Atlas stent provides limited support for the WEB device. In similar situations, gently repositioning the protruded WEB back into the aneurysm sac may be a remedial measure. Video 1 Technical video demonstrating rescue techniques for managing intravascular mechanical obstruction following detachment of the WEB device:
- 20 October 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (12) , 1215
Rescue techniques for intravascular mechanical obstruction following Woven EndoBridge (WEB) device detachment
The Woven EndoBridge (WEB) device is a well established treatment for bifurcation aneurysms.1–6 However, failed detachment after deployment can present significant challenges. In this technical video (video 1), we report on a patient with a left middle cerebral artery (MCA) bifurcation aneurysm treated with the WEB device. Despite satisfactory deployment, multiple detachment attempts were unsuccessful. After repeated maneuvers, the WEB was finally detached but slightly protruded from the aneurysm sac, compromising blood flow in the superior branch of the MCA. Even after placing an Atlas stent, blood flow was not restored. Ultimately, using a microguidewire and microcatheter, we repositioned the protruded WEB device back into the aneurysm sac, successfully restoring blood flow. This case illustrates that the Atlas stent provides limited support for the WEB device. In similar situations, gently repositioning the protruded WEB back into the aneurysm sac may be a remedial measure. Video 1 Technical video demonstrating rescue techniques for managing intravascular mechanical obstruction following detachment of the WEB device:
- 28 August 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (10) , 1089-1095
Rupture risk assessment in cerebral arteriovenous malformations: an ensemble model using hemodynamic and morphological features
Background Cerebral arteriovenous malformation (AVM) is a cerebrovascular disorder posing a risk for intracranial hemorrhage. However, there are few reliable quantitative indices to predict hemorrhage risk accurately. This study aimed to identify potential biomarkers for hemorrhage risk by quantitatively analyzing the hemodynamic and morphological features within the AVM nidus. Methods This study included three datasets comprising consecutive patients with untreated AVMs between January 2008 to December 2023. Training and test datasets were used to train and evaluate the model. An independent validation dataset of patients receiving conservative treatment was used to evaluate the model performance in predicting subsequent hemorrhage during follow-up. Hemodynamic and morphological features were quantitatively extracted based on digital subtraction angiography (DSA). Individual models using various machine learning algorithms and an ensemble model were constructed on the training dataset. Model performance was assessed using the confusion matrix-related metrics. Results This study included 844 patients with AVMs, distributed across the training (n=597), test (n=149), and validation (n=98) datasets. Five hemodynamic and 14 morphological features were quantitatively extracted for each patient. The ensemble model, constructed based on five individual machine-learning models, achieved an area under the curve of 0.880 (0.824–0.937) on the test dataset and 0.864 (0.769–0.959) on the independent validation dataset. Conclusion Quantitative hemodynamic and morphological features extracted from DSA data serve as potential indicators for assessing the rupture risk of AVM. The ensemble model effectively integrated multidimensional features, demonstrating favorable performance in predicting subsequent rupture of AVM.
- 28 August 2024
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 17 (10) , 1089-1095
Rupture risk assessment in cerebral arteriovenous malformations: an ensemble model using hemodynamic and morphological features
Background Cerebral arteriovenous malformation (AVM) is a cerebrovascular disorder posing a risk for intracranial hemorrhage. However, there are few reliable quantitative indices to predict hemorrhage risk accurately. This study aimed to identify potential biomarkers for hemorrhage risk by quantitatively analyzing the hemodynamic and morphological features within the AVM nidus. Methods This study included three datasets comprising consecutive patients with untreated AVMs between January 2008 to December 2023. Training and test datasets were used to train and evaluate the model. An independent validation dataset of patients receiving conservative treatment was used to evaluate the model performance in predicting subsequent hemorrhage during follow-up. Hemodynamic and morphological features were quantitatively extracted based on digital subtraction angiography (DSA). Individual models using various machine learning algorithms and an ensemble model were constructed on the training dataset. Model performance was assessed using the confusion matrix-related metrics. Results This study included 844 patients with AVMs, distributed across the training (n=597), test (n=149), and validation (n=98) datasets. Five hemodynamic and 14 morphological features were quantitatively extracted for each patient. The ensemble model, constructed based on five individual machine-learning models, achieved an area under the curve of 0.880 (0.824–0.937) on the test dataset and 0.864 (0.769–0.959) on the independent validation dataset. Conclusion Quantitative hemodynamic and morphological features extracted from DSA data serve as potential indicators for assessing the rupture risk of AVM. The ensemble model effectively integrated multidimensional features, demonstrating favorable performance in predicting subsequent rupture of AVM.
- Open Access
- 1 January 2024
- Published by XMLink in Korean Journal of Radiology
- Vol. 25 (1) , 74-85
Prediction of Venous Trans-Stenotic Pressure Gradient Using Shape Features Derived From Magnetic Resonance Venography in Idiopathic Intracranial Hypertension Patients
Ma C, et al. Korean J Radiol. 2024 Jan;25(1):74-85. https://doi.org/10.3348/kjr.2023.0911
- 1 January 2024
- Published by XMLink in Korean Journal of Radiology
- Vol. 25 (1) , 74-85
Open AccessPrediction of Venous Trans-Stenotic Pressure Gradient Using Shape Features Derived From Magnetic Resonance Venography in Idiopathic Intracranial Hypertension Patients
Ma C, et al. Korean J Radiol. 2024 Jan;25(1):74-85. https://doi.org/10.3348/kjr.2023.0911