Yuri Sagisaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yuri Sagisaka has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Go Takai
Department of Radiology, Kansai Electric Power Hospital, Osaka-Shi, Japan
1 shared publication - Hiroki Yamamoto
Department of Radiology, Division of Medical Technology, Hirosaki University Hospital, 53 Hon-cho, Hirosaki 036-8563, Japan
1 shared publication - Keiji Nagano
Division of Radiation Management Center, Dokkyo Medical University Hospital, 880 Kitakobayashi, Mibumachi, Shimotsuga-gun, Tochigi 321-0293, Japan
1 shared publication - Niina Kanazawa
Department of Radiological Technology, Nihon University Itabashi Hospital, 30-1 Oyaguchi kami-cho Itabashi-ku, Tokyo 173-8610, Japan
1 shared publication - Shota Hosokawa
Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Aomori, Japan
1 shared publication - Yasuyuki Takahashi
Department of Radiation Science, Graduate School of Health Sciences, Hirosaki University, 66-1 Hon-cho, Hirosaki 036-8564, Aomori, Japan
1 shared publication
Latest Publications
- Open Access
Acquisition Conditions for Lu-177 DOTATATE Imaging
We investigated imaging conditions for the distribution of lutetium oxodotreotide (Lu-177 DOTATATE) in the body during peptide receptor radionuclide therapy for neuroendocrine tumor (NET). We investigated imaging conditions using gamma rays emitted from the radionuclide. The gamma rays had energy peaks at 113 and 208 keV and characteristic X-rays at 56 keV. Image quality was compared by utilizing a combination of low–medium-energy general-purpose (LMEGP) and medium-energy general-purpose (MEGP) collimators. This study included the measurement of total spatial resolution (Full Width at Half Maximum) using a line source phantom. We compared the image quality of static images using a plane phantom and SPECT images using a cylindrical phantom. This comparison involved assessing recovery coefficient curves, count ratio, and %CV. Imaging evaluation was also performed on one NET patient. In phantom studies and the clinical study, comparing the combination of the three energy peaks (56 + 113 + 208 keV) using the LMEGP collimator and the conventional combination (113 + 208 keV) using the MEGP collimator revealed a count ratio of 1.9 times the maximum, stable %CV, and the best image quality.
Open AccessAcquisition Conditions for Lu-177 DOTATATE Imaging
We investigated imaging conditions for the distribution of lutetium oxodotreotide (Lu-177 DOTATATE) in the body during peptide receptor radionuclide therapy for neuroendocrine tumor (NET). We investigated imaging conditions using gamma rays emitted from the radionuclide. The gamma rays had energy peaks at 113 and 208 keV and characteristic X-rays at 56 keV. Image quality was compared by utilizing a combination of low–medium-energy general-purpose (LMEGP) and medium-energy general-purpose (MEGP) collimators. This study included the measurement of total spatial resolution (Full Width at Half Maximum) using a line source phantom. We compared the image quality of static images using a plane phantom and SPECT images using a cylindrical phantom. This comparison involved assessing recovery coefficient curves, count ratio, and %CV. Imaging evaluation was also performed on one NET patient. In phantom studies and the clinical study, comparing the combination of the three energy peaks (56 + 113 + 208 keV) using the LMEGP collimator and the conventional combination (113 + 208 keV) using the MEGP collimator revealed a count ratio of 1.9 times the maximum, stable %CV, and the best image quality.