Pierre-Emmanuel Moreau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pierre-Emmanuel Moreau has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Guillaume Riouallon
Hôpital Paris Saint-Joseph, Paris, France
13 shared publications Peter Upex
5 shared publications- Elias Melhem
Department of Orthopedic Surgery, Groupe Hospitalier Paris Saint Joseph, Paris, France
4 shared publications - Peter Upex
Orthopedic and Traumatology Surgery Department, Hôpital Paris Saint-Joseph, Paris, France
4 shared publications - Ali Ghoul
Hôpital Paris Saint-Joseph, Paris, France
2 shared publications - Anaïs Bernardeau
Orthopedic surgery department, Groupe hospitalier Paris Saint-Joseph, 185 rue Raymond Losserand, 75014, Paris, France
2 shared publications
Latest Publications
- 2 October 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
Postoperative Management of Direct Oral Anticoagulants After Elective Spine Surgery
Study design: Retrospective monocentric study. Objectives: To determine a safe interval for the resumption of DOACs based on the risk of postoperative surgical reoperation in the month following spine surgery. Summary of Background Data: More patients scheduled for spine surgeries are being treated with direct oral anticoagulants (DOACs). Scientific society guidelines recommend the resumption of DOACs 2–3 days postoperatively. However, spine surgeries could be associated with an increased risk of complications warranting urgent surgical revision. Early resumption of DOACs imposes a 3–5-day delay before any possible intervention, raising challenges for the surgeon. Methods: All patients who had spine surgery between 2006 and 2020 were included. Data on the occurrence of reoperation, age, sex, duration of surgery, surgeon’s experience, year, and type of surgery were collected. The main outcome was the occurrence of reoperation and the time to reoperation. Results: In total, 2540 patients, who underwent 3109 spine surgeries, were included. There were 260 reoperations that occurred in the month following the index surgery, of which 230 (7.39%) were due to complications requiring urgent revision surgery. More than 80% of the revision surgeries occurred within the 15 days following the index surgery, with half occurring after postoperative day 5. A longer duration of the surgery, nighttime surgery, and the type of surgery (multilevel fusions, surgery for surgical site infection) were associated with a significantly increased risk of revision within the month following the surgery. Conclusions: Although the resumption of DOACs 2–3 days postoperatively is safe in terms of bleeding risk, we believe that this interval is short considering the risk of revision during the first month after surgery. Timing of DOACs’ resumption should be tailored to the patient’s comorbidities and to the surgical characteristics; it should sometimes involve a multidisciplinary discussion.
- 2 October 2026
- Published by Wolters Kluwer Health in Clinical Spine Surgery
Postoperative Management of Direct Oral Anticoagulants After Elective Spine Surgery
Study design: Retrospective monocentric study. Objectives: To determine a safe interval for the resumption of DOACs based on the risk of postoperative surgical reoperation in the month following spine surgery. Summary of Background Data: More patients scheduled for spine surgeries are being treated with direct oral anticoagulants (DOACs). Scientific society guidelines recommend the resumption of DOACs 2–3 days postoperatively. However, spine surgeries could be associated with an increased risk of complications warranting urgent surgical revision. Early resumption of DOACs imposes a 3–5-day delay before any possible intervention, raising challenges for the surgeon. Methods: All patients who had spine surgery between 2006 and 2020 were included. Data on the occurrence of reoperation, age, sex, duration of surgery, surgeon’s experience, year, and type of surgery were collected. The main outcome was the occurrence of reoperation and the time to reoperation. Results: In total, 2540 patients, who underwent 3109 spine surgeries, were included. There were 260 reoperations that occurred in the month following the index surgery, of which 230 (7.39%) were due to complications requiring urgent revision surgery. More than 80% of the revision surgeries occurred within the 15 days following the index surgery, with half occurring after postoperative day 5. A longer duration of the surgery, nighttime surgery, and the type of surgery (multilevel fusions, surgery for surgical site infection) were associated with a significantly increased risk of revision within the month following the surgery. Conclusions: Although the resumption of DOACs 2–3 days postoperatively is safe in terms of bleeding risk, we believe that this interval is short considering the risk of revision during the first month after surgery. Timing of DOACs’ resumption should be tailored to the patient’s comorbidities and to the surgical characteristics; it should sometimes involve a multidisciplinary discussion.
- Open Access
- 26 August 2026
- Published by Elsevier in SSRN Electronic Journal
Computed Tomography-Based Three-Dimensional Analysis of Acetabular Fractures With a Transverse Component
BackgroundAcetabular fractures with a transverse component are challenging because they involve both columns and often have unfavorable outcomes. Few studies have examined their three-dimensional orientation and implications for surgical planning.HypothesisWe hypothesized that the three-dimensional orientation of fracture planes is highly variable and cannot be reliably predicted by conventional fracture morphology.MethodsThis was a retrospective study including patients treated between 2018 and 2025 for acetabular fractures with a transverse component (pure transverse fractures, T-shaped fractures, and transverse fractures with a posterior wall). Patients with associated pelvic ring injuries or insufficient computed tomography image quality were excluded. Three-dimensional reconstructions of the fracture planes were obtained from CT using 3D Slicer software. Two theoretical reference planes were created, corresponding to the optimal planes for the anterior intrapelvic and pararectus approaches. The orientation of each fracture plane and of the two reference planes was measured relative to the anterior pelvic plane using the Angle Planes extension. Pitch, Yaw, and Roll were recorded as angular parameters. Fracture-line height and tectal or infratectal location were also analyzed.ResultsSixty-five fractures were included: 28 pure transverse fractures(43.1%), 22 T-shaped fractures (33.8%), and 15 transverse fractures with posterior wall(23.1%). Mean age was 44.4 ± 18.8 years. Mean angular values were 89.9° ± 28.0° for Pitch, 91.9° ± 29.7° for Yaw, and 87.1° ± 31.1° for Roll. No significant difference was found between fracture types for Pitch (p = 0.516), Yaw (p = 0.518), or Roll (p = 0.308). 37 fractures were closer to the anterior intrapelvic reference plane, whereas 28 fractures were closer to the pararectus reference plane. Thirty-five fractures were tectal, with no significant angular difference between groups. Mean anterior and posterior fracture-line heights were 18.5 ± 4.1 mm and 29.5 ± 9.8 mm. Posterior height was significantly higher in pure transverse fractures than in T-shaped fractures (32.6 ± 7.8 mm vs. 23.7 ± 10.7 mm; p = 0.003).DiscussionAcetabular fractures with a transverse component showed three-dimensional variability not predicted by conventional fracture morphology. Computed tomography-based three-dimensional analysis may help characterize individual fracture orientation and assist in selecting the optimal surgical exposure for the fracture plane.
- 26 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessComputed Tomography-Based Three-Dimensional Analysis of Acetabular Fractures With a Transverse Component
BackgroundAcetabular fractures with a transverse component are challenging because they involve both columns and often have unfavorable outcomes. Few studies have examined their three-dimensional orientation and implications for surgical planning.HypothesisWe hypothesized that the three-dimensional orientation of fracture planes is highly variable and cannot be reliably predicted by conventional fracture morphology.MethodsThis was a retrospective study including patients treated between 2018 and 2025 for acetabular fractures with a transverse component (pure transverse fractures, T-shaped fractures, and transverse fractures with a posterior wall). Patients with associated pelvic ring injuries or insufficient computed tomography image quality were excluded. Three-dimensional reconstructions of the fracture planes were obtained from CT using 3D Slicer software. Two theoretical reference planes were created, corresponding to the optimal planes for the anterior intrapelvic and pararectus approaches. The orientation of each fracture plane and of the two reference planes was measured relative to the anterior pelvic plane using the Angle Planes extension. Pitch, Yaw, and Roll were recorded as angular parameters. Fracture-line height and tectal or infratectal location were also analyzed.ResultsSixty-five fractures were included: 28 pure transverse fractures(43.1%), 22 T-shaped fractures (33.8%), and 15 transverse fractures with posterior wall(23.1%). Mean age was 44.4 ± 18.8 years. Mean angular values were 89.9° ± 28.0° for Pitch, 91.9° ± 29.7° for Yaw, and 87.1° ± 31.1° for Roll. No significant difference was found between fracture types for Pitch (p = 0.516), Yaw (p = 0.518), or Roll (p = 0.308). 37 fractures were closer to the anterior intrapelvic reference plane, whereas 28 fractures were closer to the pararectus reference plane. Thirty-five fractures were tectal, with no significant angular difference between groups. Mean anterior and posterior fracture-line heights were 18.5 ± 4.1 mm and 29.5 ± 9.8 mm. Posterior height was significantly higher in pure transverse fractures than in T-shaped fractures (32.6 ± 7.8 mm vs. 23.7 ± 10.7 mm; p = 0.003).DiscussionAcetabular fractures with a transverse component showed three-dimensional variability not predicted by conventional fracture morphology. Computed tomography-based three-dimensional analysis may help characterize individual fracture orientation and assist in selecting the optimal surgical exposure for the fracture plane.
- 20 July 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 291
Operative time in acetabular fracture fixation: predictors and impact on postoperative outcomes
Background Surgical fixation of acetabular fractures is technically demanding, and operative time is often treated as a surrogate for surgical complexity and a presumed driver of complications. Whether prolonged operative time reflects identifiable preoperative factors, and whether it independently worsens outcomes, remains unclear. We aimed to identify factors associated with prolonged operative time in acetabular fracture fixation and to determine whether longer operative time is associated with worse postoperative outcomes. Methods We retrospectively reviewed patients undergoing surgical fixation for acetabular fracture at a single center with a minimum follow-up of 3 months. Operative time was dichotomized at the median (127 min) into short (≤ 127 min) and long (> 127 min) operative time groups. Results A total of 441 patients were included (222 short, 219 long). On univariate analysis, long operative time was associated with lower preoperative hemoglobin (11.8 ± 1.7 vs. 12.3 ± 1.7 g/dL, p = 0.001), high-energy trauma (83.7% vs. 72.3%, p = 0.004), the presence of associated lesions (48.4% vs. 31.5%, p < 0.001), an anterior-predominant fracture pattern and use of a combined surgical approach (both p < 0.001), and a longer time to surgery (8.9 ± 5.4 vs. 7.6 ± 5.3 days, p = 0.011). Conversely, dislocation (22.2% vs. 40.6%, p < 0.001), posterior wall involvement (p = 0.001), and femoral head lesions (p = 0.020) were more frequent in the short operative time group at presentation. On multivariable regression, the presence of associated lesions (OR 1.8, p = 0.02) and high-energy trauma (OR 1.9, p = 0.02) independently predicted long operative time, whereas dislocation was independently associated with shorter operative time (OR 0.5, p = 0.007). Notably, long operative time was not associated with higher rates of infection, heterotopic ossification, femoral head necrosis, post-traumatic osteoarthritis, or conversion to total hip arthroplasty. Conclusion In acetabular fracture fixation, prolonged operative time was driven primarily by case complexity particularly associated lesions, and trauma type whereas dislocation, typically addressed through a single posterior approach, was associated with shorter operations. Longer operative time did not translate into worse postoperative outcomes. Level of evidence III.
- 20 July 2026
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 36 (1) , 291
Operative time in acetabular fracture fixation: predictors and impact on postoperative outcomes
Background Surgical fixation of acetabular fractures is technically demanding, and operative time is often treated as a surrogate for surgical complexity and a presumed driver of complications. Whether prolonged operative time reflects identifiable preoperative factors, and whether it independently worsens outcomes, remains unclear. We aimed to identify factors associated with prolonged operative time in acetabular fracture fixation and to determine whether longer operative time is associated with worse postoperative outcomes. Methods We retrospectively reviewed patients undergoing surgical fixation for acetabular fracture at a single center with a minimum follow-up of 3 months. Operative time was dichotomized at the median (127 min) into short (≤ 127 min) and long (> 127 min) operative time groups. Results A total of 441 patients were included (222 short, 219 long). On univariate analysis, long operative time was associated with lower preoperative hemoglobin (11.8 ± 1.7 vs. 12.3 ± 1.7 g/dL, p = 0.001), high-energy trauma (83.7% vs. 72.3%, p = 0.004), the presence of associated lesions (48.4% vs. 31.5%, p < 0.001), an anterior-predominant fracture pattern and use of a combined surgical approach (both p < 0.001), and a longer time to surgery (8.9 ± 5.4 vs. 7.6 ± 5.3 days, p = 0.011). Conversely, dislocation (22.2% vs. 40.6%, p < 0.001), posterior wall involvement (p = 0.001), and femoral head lesions (p = 0.020) were more frequent in the short operative time group at presentation. On multivariable regression, the presence of associated lesions (OR 1.8, p = 0.02) and high-energy trauma (OR 1.9, p = 0.02) independently predicted long operative time, whereas dislocation was independently associated with shorter operative time (OR 0.5, p = 0.007). Notably, long operative time was not associated with higher rates of infection, heterotopic ossification, femoral head necrosis, post-traumatic osteoarthritis, or conversion to total hip arthroplasty. Conclusion In acetabular fracture fixation, prolonged operative time was driven primarily by case complexity particularly associated lesions, and trauma type whereas dislocation, typically addressed through a single posterior approach, was associated with shorter operations. Longer operative time did not translate into worse postoperative outcomes. Level of evidence III.
- 20 December 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- p. 104579
Acetabular fractures with transverse component: Predictors of radiological and clinical outcomes
- 20 December 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- p. 104579
Acetabular fractures with transverse component: Predictors of radiological and clinical outcomes
- 2 October 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (12) , 3456-3465
Comparison of Different Bipolar Construct Configurations for the Correction of Adult Spine Deformity: A Finite Element Analysis
Purpose A minimally invasive bipolar spinal fixation was recently developed to correct the deformity in pediatric neuromuscular scoliosis and has recently been adapted for adult scoliosis. Although the clinical results are promising, mechanical complications are still not negligible. In this work, alternative configurations of bipolar constructs were compared through numerical simulation, in order to evaluate stress distribution along the implant according to each configuration. Methods The configurations included doubling the rods, adding lumbar screws to strengthen the distal anchorage, and combining two different materials (titanium and chromium-cobalt alloy). This resulted in seven different configurations, which were implemented in a subject-specific and experimentally validated finite element model, based on the geometry of an asymptomatic subject. Von Mises stresses were compared between configurations. Results The results confirm that doubling the rods reduced mid-rod stresses, as expected, but also shifted some of the load from the distal anchorage to the rods, which is a common site of implant failure. The addition of pedicle screws also reduced the stress in the distal anchorage. The configuration showing the best compromise between stress reduction and the mini-invasive character of surgery included a doubling of both rods in titanium. Conclusions These results should be confirmed by clinical results, but they already provide clear guidelines for the surgeon.
- 2 October 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (12) , 3456-3465
Comparison of Different Bipolar Construct Configurations for the Correction of Adult Spine Deformity: A Finite Element Analysis
Purpose A minimally invasive bipolar spinal fixation was recently developed to correct the deformity in pediatric neuromuscular scoliosis and has recently been adapted for adult scoliosis. Although the clinical results are promising, mechanical complications are still not negligible. In this work, alternative configurations of bipolar constructs were compared through numerical simulation, in order to evaluate stress distribution along the implant according to each configuration. Methods The configurations included doubling the rods, adding lumbar screws to strengthen the distal anchorage, and combining two different materials (titanium and chromium-cobalt alloy). This resulted in seven different configurations, which were implemented in a subject-specific and experimentally validated finite element model, based on the geometry of an asymptomatic subject. Von Mises stresses were compared between configurations. Results The results confirm that doubling the rods reduced mid-rod stresses, as expected, but also shifted some of the load from the distal anchorage to the rods, which is a common site of implant failure. The addition of pedicle screws also reduced the stress in the distal anchorage. The configuration showing the best compromise between stress reduction and the mini-invasive character of surgery included a doubling of both rods in titanium. Conclusions These results should be confirmed by clinical results, but they already provide clear guidelines for the surgeon.
- 16 July 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-6
Accuracy of sacroiliac screw placement using O-arm and 3D navigation: a case series
Purpose Percutaneous fixation of pelvic fractures using sacroiliac (SI) screws is recognized as a less invasive alternative to open surgery. Despite advancements in this technique, complications still occur. This study aims to evaluate the accuracy of IS screw placement assisted by intraoperative 3D navigation. Methods A retrospective study was conducted on patients treated for sacral fractures or SI joint dislocations between 2016 and 2023 at a single institution. All procedures were performed using O-Arm 3D fluoroscopy and StealthStation S8 navigation platform (Medtronic). For each screw, all accuracy measurements—including length, angulation, and cortical perforation—were performed on the final 3D scans. Results Of the 241 screws implanted, 83.2% showed no perforation. Screw angulation was generally less accurate, with 26.5% of screws showing a minor deviation of 5° from the ideal trajectory. Accuracy was significantly lower in the axial plane compared to the coronal plane. On average, the implanted screws reached 78% of the maximum length the S1 corridor could accommodate. Conclusion This study represents the largest series to date of SI screw implantation using 3D navigation. Navigation proved to be safe for IS screw placement. Although overall accuracy in our series was slightly lower than that reported in other studies using the O-Arm, our sample included six times more patients, multiple surgeons, and a heterogeneous cohort. 3D navigation with O-Arm proved more helpful in avoiding cortical perforations than in improving screw angulation.
- 16 July 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-6
Accuracy of sacroiliac screw placement using O-arm and 3D navigation: a case series
Purpose Percutaneous fixation of pelvic fractures using sacroiliac (SI) screws is recognized as a less invasive alternative to open surgery. Despite advancements in this technique, complications still occur. This study aims to evaluate the accuracy of IS screw placement assisted by intraoperative 3D navigation. Methods A retrospective study was conducted on patients treated for sacral fractures or SI joint dislocations between 2016 and 2023 at a single institution. All procedures were performed using O-Arm 3D fluoroscopy and StealthStation S8 navigation platform (Medtronic). For each screw, all accuracy measurements—including length, angulation, and cortical perforation—were performed on the final 3D scans. Results Of the 241 screws implanted, 83.2% showed no perforation. Screw angulation was generally less accurate, with 26.5% of screws showing a minor deviation of 5° from the ideal trajectory. Accuracy was significantly lower in the axial plane compared to the coronal plane. On average, the implanted screws reached 78% of the maximum length the S1 corridor could accommodate. Conclusion This study represents the largest series to date of SI screw implantation using 3D navigation. Navigation proved to be safe for IS screw placement. Although overall accuracy in our series was slightly lower than that reported in other studies using the O-Arm, our sample included six times more patients, multiple surgeons, and a heterogeneous cohort. 3D navigation with O-Arm proved more helpful in avoiding cortical perforations than in improving screw angulation.
- 11 July 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (9) , 2281-2288
Return to sport following acetabular fracture fixation: insights from a specialist tertiary centre on outcomes and key predictors
Purpose This investigation examined return-to-sport (RTS) outcomes and performance determinants following surgical fixation of acetabular fractures in young athletes. The primary objectives were to quantify RTS rates, evaluate functional outcomes, and identify key predictors of athletic recovery. Methods We conducted a retrospective analysis of 62 patients (mean age: 29.6 years) who underwent acetabular fracture fixation at a tertiary care centre. The investigation encompassed pre- and post-operative athletic participation, patient satisfaction metrics, and psychological readiness assessments. Primary outcome measures included stratified RTS rates, with functional and psychological parameters evaluated using the Copenhagen Hip and Groin Outcome Score (HAGOS) and Hip Return to Sport after Injury (Hip-RSI) scale. Results While 82.3% of patients resumed athletic activities, 53.2% returned to their primary sport, with only 19.4% achieving pre-injury performance levels. Multivariate analysis revealed that superior articular reduction quality and elevated psychological readiness scores, as measured by the Hip-RSI, were significant predictors of successful RTS outcomes. Conclusion Despite encouraging overall RTS rates, restoration of pre-injury athletic performance remains challenging. The study highlights the critical role of both psychological preparedness and anatomical reduction quality in optimizing outcomes.
- 11 July 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (9) , 2281-2288
Return to sport following acetabular fracture fixation: insights from a specialist tertiary centre on outcomes and key predictors
Purpose This investigation examined return-to-sport (RTS) outcomes and performance determinants following surgical fixation of acetabular fractures in young athletes. The primary objectives were to quantify RTS rates, evaluate functional outcomes, and identify key predictors of athletic recovery. Methods We conducted a retrospective analysis of 62 patients (mean age: 29.6 years) who underwent acetabular fracture fixation at a tertiary care centre. The investigation encompassed pre- and post-operative athletic participation, patient satisfaction metrics, and psychological readiness assessments. Primary outcome measures included stratified RTS rates, with functional and psychological parameters evaluated using the Copenhagen Hip and Groin Outcome Score (HAGOS) and Hip Return to Sport after Injury (Hip-RSI) scale. Results While 82.3% of patients resumed athletic activities, 53.2% returned to their primary sport, with only 19.4% achieving pre-injury performance levels. Multivariate analysis revealed that superior articular reduction quality and elevated psychological readiness scores, as measured by the Hip-RSI, were significant predictors of successful RTS outcomes. Conclusion Despite encouraging overall RTS rates, restoration of pre-injury athletic performance remains challenging. The study highlights the critical role of both psychological preparedness and anatomical reduction quality in optimizing outcomes.
- Open Access
- 14 September 2024
- Published by Elsevier in Trauma & Case Reports
- Vol. 54, 101107
Pubic symphysis tethering technique under endoscopic approach for treatment of pelvic open-book injury: A cadaver study
- 14 September 2024
- Published by Elsevier in Trauma & Case Reports
- Vol. 54, 101107
Open AccessPubic symphysis tethering technique under endoscopic approach for treatment of pelvic open-book injury: A cadaver study
- Open Access
- 23 August 2024
- Published by MDPI AG in Antibiotics
- Vol. 13 (9) , 791
Microbiological Profile of Instrumented Spinal Infections: 10-Year Study at a French Spine Center
Objective: The objective was to compare the microbiological characteristics and treatment of early and late surgical site infections (SSIs) in instrumented spinal surgery. Methods: Those patients admitted for SSIs in a single center between January 2010 and December 2022 were included. The subjects were divided into early (eSSIs) and late (lSSIs) SSIs, and demographic, microbiological, treatment, and follow-up data were collected. Results: Instrumented spinal surgery was performed in 2136 patients. Ninety-six cases of infections were identified (prevalence = 4.5%), with 47.9% eSSIs and 52.1% lSSIs. In 58.7% of the cases, the eSSIs were monomicrobial: Staphylococcus aureus (37%) and Enterobacterales (33.3%) were the main bacteria involved. In 66% of the cases, the lSSIs, were monomicrobial: Cutibacterium acnes (30.3%) and staphylococci were predominant. Enterobacterales were isolated in more than 70% of the polymicrobial samples in both the eSSIs and lSSIs. The treatment of the eSSIs mostly consisted of lavage-debridement surgery associated with antibiotic treatment, while the treatment of the lSSIs combined hardware removal or replacement and long-duration antibiotic treatment. A negative outcome was observed in 17.1% of the eSSIs and 5.7% of the lSSIs. Enterobacterales were associated with negative outcomes of eSSIs. Conclusions: Enterobacterales were found in most of the polymicrobial infections regardless of the time of infection onset. Further large studies should be conducted to precisely determine the management and prevention regarding the increasing Gram-negative bacteria SSIs.
- 23 August 2024
- Published by MDPI AG in Antibiotics
- Vol. 13 (9) , 791
Open AccessMicrobiological Profile of Instrumented Spinal Infections: 10-Year Study at a French Spine Center
Objective: The objective was to compare the microbiological characteristics and treatment of early and late surgical site infections (SSIs) in instrumented spinal surgery. Methods: Those patients admitted for SSIs in a single center between January 2010 and December 2022 were included. The subjects were divided into early (eSSIs) and late (lSSIs) SSIs, and demographic, microbiological, treatment, and follow-up data were collected. Results: Instrumented spinal surgery was performed in 2136 patients. Ninety-six cases of infections were identified (prevalence = 4.5%), with 47.9% eSSIs and 52.1% lSSIs. In 58.7% of the cases, the eSSIs were monomicrobial: Staphylococcus aureus (37%) and Enterobacterales (33.3%) were the main bacteria involved. In 66% of the cases, the lSSIs, were monomicrobial: Cutibacterium acnes (30.3%) and staphylococci were predominant. Enterobacterales were isolated in more than 70% of the polymicrobial samples in both the eSSIs and lSSIs. The treatment of the eSSIs mostly consisted of lavage-debridement surgery associated with antibiotic treatment, while the treatment of the lSSIs combined hardware removal or replacement and long-duration antibiotic treatment. A negative outcome was observed in 17.1% of the eSSIs and 5.7% of the lSSIs. Enterobacterales were associated with negative outcomes of eSSIs. Conclusions: Enterobacterales were found in most of the polymicrobial infections regardless of the time of infection onset. Further large studies should be conducted to precisely determine the management and prevention regarding the increasing Gram-negative bacteria SSIs.