Hisashi Kitamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hisashi Kitamura has a total of 206 co-authors. Here are the top co-authors by number of shared publications:
- Kouichi Hagino
10Department of Physics, University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
4 shared publications - Jun Nishimura
High Energy Accelerator Research Organization
3 shared publications K. Mizutani
Saitama University, Japan
3 shared publications- Katsuaki Kasahara
Faculty of Systems Engineering and Science Shibaura Institute of Technology Tokyo Japan
3 shared publications - Kinya Hibino
Kanagawa University
3 shared publications M. Shibata
Yokohama National University, Japan
3 shared publications
Latest Publications
- Open Access
- 23 November 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
TP53 -dependent bystander cell-killing effect in human cell lines irradiated with carbon ions
Since 1994, radiotherapy has used carbon ions at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Direct biological effects for high linear energy transfer (LET) heavy-ion beams are reported to be higher than those for low-LET X or gamma rays. However, it is still not clear against indirect biological effects, such as bystander effects, which can be defined as the ability to convey signs of damage to not directly irradiated neighboring cells from directly irradiated cells. In this study, we studied TP53-dependent bystander cell-killing effects induced by either a broad beam or a microbeam of high-LET carbon ions. Ten human cell lines with normal or cancer origins harboring with wild-type or mutated type TP53 gene were used. The results demonstrated an enhanced cell-killing effect in cells harboring with wild-type TP53, but not with mutant TP53. Furthermore, the data suggests that cell-to-cell communication mediated by gap junction plays a key role in inducing a bystander effect.
- 23 November 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
Open AccessTP53 -dependent bystander cell-killing effect in human cell lines irradiated with carbon ions
Since 1994, radiotherapy has used carbon ions at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Direct biological effects for high linear energy transfer (LET) heavy-ion beams are reported to be higher than those for low-LET X or gamma rays. However, it is still not clear against indirect biological effects, such as bystander effects, which can be defined as the ability to convey signs of damage to not directly irradiated neighboring cells from directly irradiated cells. In this study, we studied TP53-dependent bystander cell-killing effects induced by either a broad beam or a microbeam of high-LET carbon ions. Ten human cell lines with normal or cancer origins harboring with wild-type or mutated type TP53 gene were used. The results demonstrated an enhanced cell-killing effect in cells harboring with wild-type TP53, but not with mutant TP53. Furthermore, the data suggests that cell-to-cell communication mediated by gap junction plays a key role in inducing a bystander effect.
- 8 January 2024
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 696, 149500
The contribution of high-LET track to DNA damage formation and cell death for Monoenergy and SOBP carbon ion irradiation
- 8 January 2024
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 696, 149500
The contribution of high-LET track to DNA damage formation and cell death for Monoenergy and SOBP carbon ion irradiation
- Open Access
- 28 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 10 (01) , 016001-11
Development of the focal-plane CMOS detector for the GEO-X mission
We report a development status of a focal plane detector for the GEO-X (GEOspace X-ray imager) mission that will perform soft X-ray (≤2 keV) imaging spectroscopy of Earth’s magnetosphere from a micro satellite. The mission instrument consists of a microelectromechanical systems (MEMS) X-ray mirror and a focal plane detector. A sensor with fine positional resolution and moderate energy resolution in the energy band of 0.3 to 2 keV is required. Because the observing target is the magnetosphere around the day-side Earth, the visible-light background must be decreased by shortening the integration time for readout. To satisfy the above requirements, a high-speed X-ray CMOS sensor is being evaluated as a primary candidate for the detector. Irradiating the flight candidate sensor with monochromatic X-rays, we obtained the energy resolution of 205 eV (FWHM) at 6 keV by cooling the devices to −15°C. Radiation tolerance of the sensor, especially in terms of total dose effect, is investigated with 100 MeV proton. The amount of degradation of energy resolution is <50 eV up to 10 krad, which ensures that we will be able to track and calibrate the change of the line width in orbit.
- 28 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 10 (01) , 016001-11
Open AccessDevelopment of the focal-plane CMOS detector for the GEO-X mission
We report a development status of a focal plane detector for the GEO-X (GEOspace X-ray imager) mission that will perform soft X-ray (≤2 keV) imaging spectroscopy of Earth’s magnetosphere from a micro satellite. The mission instrument consists of a microelectromechanical systems (MEMS) X-ray mirror and a focal plane detector. A sensor with fine positional resolution and moderate energy resolution in the energy band of 0.3 to 2 keV is required. Because the observing target is the magnetosphere around the day-side Earth, the visible-light background must be decreased by shortening the integration time for readout. To satisfy the above requirements, a high-speed X-ray CMOS sensor is being evaluated as a primary candidate for the detector. Irradiating the flight candidate sensor with monochromatic X-rays, we obtained the energy resolution of 205 eV (FWHM) at 6 keV by cooling the devices to −15°C. Radiation tolerance of the sensor, especially in terms of total dose effect, is investigated with 100 MeV proton. The amount of degradation of energy resolution is <50 eV up to 10 krad, which ensures that we will be able to track and calibrate the change of the line width in orbit.
- Open Access
- 1 October 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 8 (04) , 046001-7
Single event tolerance of x-ray silicon-on-insulator pixel sensors
We evaluate the single event tolerance of the x-ray silicon-on-insulator (SOI) pixel sensor named XRPIX, developed for the future x-ray astronomical satellite FORCE. In this work, we measure the cross-section of single event upset (SEU) of the shift register on XRPIX by irradiating heavy ion beams with linear energy transfer (LET) ranging from 0.022 to 68 MeV / ( mg/cm2 ) . From the SEU cross-section curve, the saturation cross-section and threshold LET are successfully obtained to be 3.4−0.9+2.9×10−10 cm2/bit and 7.3−3.5+1.9 MeV/(mg/cm2), respectively. Using these values, the SEU rate in orbit is estimated to be ≲ 0.1 event / year primarily due to the secondary particles induced by cosmic-ray protons. This SEU rate of the shift register on XRPIX is negligible in the FORCE orbit.
- 1 October 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 8 (04) , 046001-7
Open AccessSingle event tolerance of x-ray silicon-on-insulator pixel sensors
We evaluate the single event tolerance of the x-ray silicon-on-insulator (SOI) pixel sensor named XRPIX, developed for the future x-ray astronomical satellite FORCE. In this work, we measure the cross-section of single event upset (SEU) of the shift register on XRPIX by irradiating heavy ion beams with linear energy transfer (LET) ranging from 0.022 to 68 MeV / ( mg/cm2 ) . From the SEU cross-section curve, the saturation cross-section and threshold LET are successfully obtained to be 3.4−0.9+2.9×10−10 cm2/bit and 7.3−3.5+1.9 MeV/(mg/cm2), respectively. Using these values, the SEU rate in orbit is estimated to be ≲ 0.1 event / year primarily due to the secondary particles induced by cosmic-ray protons. This SEU rate of the shift register on XRPIX is negligible in the FORCE orbit.
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S90
SIGNIFICANT CHANGES IN YIELDS OF 7-HYDROXY-COUMARIN-3-CARBOXYLIC ACID PRODUCED UNDER THE FLASH RADIOTHERAPY CONDITION
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S90
SIGNIFICANT CHANGES IN YIELDS OF 7-HYDROXY-COUMARIN-3-CARBOXYLIC ACID PRODUCED UNDER THE FLASH RADIOTHERAPY CONDITION
- 1 July 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 7 (03) , 036001-14
Proton radiation hardness of x-ray SOI pixel sensors with pinned depleted diode structure
X-ray silicon-on-insulator (SOI) pixel sensors, “XRPIX,” are being developed for the next-generation x-ray astronomical satellite, “FORCE.” The XRPIX is fabricated with the SOI technology, which makes it possible to integrate a high-resistivity Si sensor and a low-resistivity Si complementary metal oxide semiconductor (CMOS) circuit. The CMOS circuit in each pixel is equipped with a trigger function, allowing us to read out outputs only from the pixels with x-ray signals at the timing of x-ray detection. This function thus realizes high throughput and high time resolution, which enables to employ anti-coincidence technique for background rejection. A new series of XRPIX named XRPIX6E developed with a pinned depleted diode (PDD) structure improves spectral performance by suppressing the interference between the sensor and circuit layers. When semiconductor x-ray sensors are used in space, their spectral performance is generally degraded owing to the radiation damage caused by high-energy protons. Therefore, before using an XRPIX in space, it is necessary to evaluate the extent of degradation of its spectral performance by radiation damage. Thus, we performed a proton irradiation experiment for XRPIX6E for the first time at Heavy Ion Medical Accelerator in Chiba in the National Institute of Radiological Sciences. We irradiated XRPIX6E with high-energy protons with a total dose of up to 40 krad, equivalent to 400 years of irradiation in orbit. The 40-krad irradiation degraded the energy resolution of XRPIX6E by 25 ± 3 % , yielding an energy resolution of 260.1 ± 5.6 eV at the full-width half maximum for 5.9 keV X-rays. However, the value satisfies the requirement for FORCE, 300 eV at 6 keV, even after the irradiation. It was also found that the PDD XRPIX has enhanced radiation hardness compared to previous XRPIX devices. In addition, we investigated the degradation of the energy resolution; it was shown that the degradation would be due to increasing energy-independent components, e.g., readout noise.
- 1 July 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 7 (03) , 036001-14
Proton radiation hardness of x-ray SOI pixel sensors with pinned depleted diode structure
X-ray silicon-on-insulator (SOI) pixel sensors, “XRPIX,” are being developed for the next-generation x-ray astronomical satellite, “FORCE.” The XRPIX is fabricated with the SOI technology, which makes it possible to integrate a high-resistivity Si sensor and a low-resistivity Si complementary metal oxide semiconductor (CMOS) circuit. The CMOS circuit in each pixel is equipped with a trigger function, allowing us to read out outputs only from the pixels with x-ray signals at the timing of x-ray detection. This function thus realizes high throughput and high time resolution, which enables to employ anti-coincidence technique for background rejection. A new series of XRPIX named XRPIX6E developed with a pinned depleted diode (PDD) structure improves spectral performance by suppressing the interference between the sensor and circuit layers. When semiconductor x-ray sensors are used in space, their spectral performance is generally degraded owing to the radiation damage caused by high-energy protons. Therefore, before using an XRPIX in space, it is necessary to evaluate the extent of degradation of its spectral performance by radiation damage. Thus, we performed a proton irradiation experiment for XRPIX6E for the first time at Heavy Ion Medical Accelerator in Chiba in the National Institute of Radiological Sciences. We irradiated XRPIX6E with high-energy protons with a total dose of up to 40 krad, equivalent to 400 years of irradiation in orbit. The 40-krad irradiation degraded the energy resolution of XRPIX6E by 25 ± 3 % , yielding an energy resolution of 260.1 ± 5.6 eV at the full-width half maximum for 5.9 keV X-rays. However, the value satisfies the requirement for FORCE, 300 eV at 6 keV, even after the irradiation. It was also found that the PDD XRPIX has enhanced radiation hardness compared to previous XRPIX devices. In addition, we investigated the degradation of the energy resolution; it was shown that the degradation would be due to increasing energy-independent components, e.g., readout noise.
- 1 October 2018
- Published by Elsevier in Acta Astronautica
- Vol. 151, 1-6
Comparison of the space bubble detector response to space-like neutron spectra and high energy protons
- 1 October 2018
- Published by Elsevier in Acta Astronautica
- Vol. 151, 1-6
Comparison of the space bubble detector response to space-like neutron spectra and high energy protons
- 1 September 2016
- Published by Elsevier in Radiation Measurements
- Vol. 92, 54-58
Exclusive attributes of undoped poly (ethylene terephthalate) for alpha particle detection
- 1 September 2016
- Published by Elsevier in Radiation Measurements
- Vol. 92, 54-58
Exclusive attributes of undoped poly (ethylene terephthalate) for alpha particle detection
- Open Access
- 29 May 2015
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 95, 04056
The CALorimetric Electron Telescope (CALET) for high-energy astroparticle physics on the International Space Station
The CALorimetric Electron Telescope (CALET) is a space experiment, currently under development by Japan in collaboration with Italy and the United States, which will measure the flux of cosmic-ray electrons (and positrons) up to 20 TeV energy, of gamma rays up to 10 TeV, of nuclei with Z from 1 to 40 up to 1 PeV energy, and will detect gamma-ray bursts in the 7 keV to 20 MeV energy range during a 5 year mission. These measurements are essential to investigate possible nearby astrophysical sources of high energy electrons, study the details of galactic particle propagation and search for dark matter signatures. The main detector of CALET, the Calorimeter, consists of a module to identify the particle charge, followed by a thin imaging calorimeter (3 radiation lengths) with tungsten plates interleaving scintillating fibre planes, and a thick energy measuring calorimeter (27 radiation lengths) composed of lead tungstate logs. The Calorimeter has the depth, imaging capabilities and energy resolution necessary for excellent separation between hadrons, electrons and gamma rays. The instrument is currently being prepared for launch (expected in 2015) to the International Space Station ISS, for installation on the Japanese Experiment Module - Exposure Facility (JEM-EF).
- 29 May 2015
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 95, 04056
Open AccessThe CALorimetric Electron Telescope (CALET) for high-energy astroparticle physics on the International Space Station
The CALorimetric Electron Telescope (CALET) is a space experiment, currently under development by Japan in collaboration with Italy and the United States, which will measure the flux of cosmic-ray electrons (and positrons) up to 20 TeV energy, of gamma rays up to 10 TeV, of nuclei with Z from 1 to 40 up to 1 PeV energy, and will detect gamma-ray bursts in the 7 keV to 20 MeV energy range during a 5 year mission. These measurements are essential to investigate possible nearby astrophysical sources of high energy electrons, study the details of galactic particle propagation and search for dark matter signatures. The main detector of CALET, the Calorimeter, consists of a module to identify the particle charge, followed by a thin imaging calorimeter (3 radiation lengths) with tungsten plates interleaving scintillating fibre planes, and a thick energy measuring calorimeter (27 radiation lengths) composed of lead tungstate logs. The Calorimeter has the depth, imaging capabilities and energy resolution necessary for excellent separation between hadrons, electrons and gamma rays. The instrument is currently being prepared for launch (expected in 2015) to the International Space Station ISS, for installation on the Japanese Experiment Module - Exposure Facility (JEM-EF).