Dugang Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dugang Kang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Lei Zhang
Chongqing Special Equipment Inspection and Research Institute, Chongqing, China
2 shared publications - Song Huang
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
2 shared publications - Wenpin Zhang
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
2 shared publications - Zhi Xiong
Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
2 shared publications - Cheng Tan
China Coal Technology Engineering Group Chongqing Research Institute, Chongqing, China
1 shared publication - Jie Chen
Key Laboratory of Electromechanical Equipment Safety in Western Complex Environment for State Market Regulation, Chongqing Special Equipment Inspection and Research Institute, Chongqing 401121, China
1 shared publication
Latest Publications
- Open Access
Deep Learning-Based Automated Detection of Welding Defects in Pressure Pipeline Radiograph
This study applies deep learning-based object detection technology to defect detection in weld radiographs, proposing a technical solution for accurately identifying the types and locations of defects in weld X-ray radiographs. The research encompasses the construction of a defect dataset, the design of a multi-model object detection network, and the development of an automated film evaluation algorithm. This technology significantly enhances the efficiency and accuracy of detecting and identifying harmful defects on weld radiographs, providing critical technical support for ensuring the safe operation and efficient maintenance of pipelines of pressure equipment.
Open AccessDeep Learning-Based Automated Detection of Welding Defects in Pressure Pipeline Radiograph
This study applies deep learning-based object detection technology to defect detection in weld radiographs, proposing a technical solution for accurately identifying the types and locations of defects in weld X-ray radiographs. The research encompasses the construction of a defect dataset, the design of a multi-model object detection network, and the development of an automated film evaluation algorithm. This technology significantly enhances the efficiency and accuracy of detecting and identifying harmful defects on weld radiographs, providing critical technical support for ensuring the safe operation and efficient maintenance of pipelines of pressure equipment.
- Open Access
- 31 October 2024
- Published by Darcy & Roy Press Co. Ltd. in Highlights in Science, Engineering and Technology
- Vol. 114, 244-252
The influence of operating parameters on the performance of PEMWE electrolytic cell
Proton exchange membrane (PEM) is considered the most promising green hydrogen production technology in the future. The proton exchange membrane electrolysis cell (PEMEC) involves a complex process of multiple physical fields, including charge transfer, gas transfer, and heat transfer, during operation. Increasing the inlet water flow rate within a certain range is beneficial for increasing the output performance of the electrolysis cell and can also reduce the average temperature of the proton exchange membrane. But when the inlet flow rate increases to a certain amount, it has no effect. As the electrolysis voltage increases, the electrochemical performance of the electrolysis cell also increases, and the temperature of the proton exchange membrane and the current density of the catalytic layer also increase with the increase of voltage.
- 31 October 2024
- Published by Darcy & Roy Press Co. Ltd. in Highlights in Science, Engineering and Technology
- Vol. 114, 244-252
Open AccessThe influence of operating parameters on the performance of PEMWE electrolytic cell
Proton exchange membrane (PEM) is considered the most promising green hydrogen production technology in the future. The proton exchange membrane electrolysis cell (PEMEC) involves a complex process of multiple physical fields, including charge transfer, gas transfer, and heat transfer, during operation. Increasing the inlet water flow rate within a certain range is beneficial for increasing the output performance of the electrolysis cell and can also reduce the average temperature of the proton exchange membrane. But when the inlet flow rate increases to a certain amount, it has no effect. As the electrolysis voltage increases, the electrochemical performance of the electrolysis cell also increases, and the temperature of the proton exchange membrane and the current density of the catalytic layer also increase with the increase of voltage.
- Open Access
Effect of Surface Reaction on the Distribution Characteristics of Temperature and OH Radicals in Microchannel Combustion
Microchannel burners suffer from low combustion efficiency and poor stability in applications. In order to explore the effect of wall reaction on methane/air premixed combustion performances in the microchannel, the effects of wall activity, inlet velocity, pressure, and equivalence ratio on the temperature and radical distribution characteristics were studied by CFD computational simulations. It is found that as the reaction pressure increases, there are more free-radical collisions, causing the reaction temperature to rise. The OH radicals participate in the reaction at the active near wall so that the mass fraction of the OH radical on the active wall is lower than that on the inert wall. As the equivalence ratio increases from 0.6 to 1.2, the high-temperature regions increase but the maximum temperature decreases. The mass fraction of OH radical increases with the increase of the equivalence ratio, and the increase of OH radical near the inert wall is larger than that of the active wall. As the flow rate increases, the disturbance increases, and the combustion reaction becomes more intense, resulting in an increase in the temperature and the mass fraction of OH radicals. The mass fraction of H, O, OH, and CH3 radicals in the inert wall was slightly higher than that in the active wall, in which the peak mass fraction of CH3 radical appeared at the axial position closest to the entrance, while the other three radicals reached the peak at about the same axial position. This study provides a reference for combustion stability in microcombustors.
Open AccessEffect of Surface Reaction on the Distribution Characteristics of Temperature and OH Radicals in Microchannel Combustion
Microchannel burners suffer from low combustion efficiency and poor stability in applications. In order to explore the effect of wall reaction on methane/air premixed combustion performances in the microchannel, the effects of wall activity, inlet velocity, pressure, and equivalence ratio on the temperature and radical distribution characteristics were studied by CFD computational simulations. It is found that as the reaction pressure increases, there are more free-radical collisions, causing the reaction temperature to rise. The OH radicals participate in the reaction at the active near wall so that the mass fraction of the OH radical on the active wall is lower than that on the inert wall. As the equivalence ratio increases from 0.6 to 1.2, the high-temperature regions increase but the maximum temperature decreases. The mass fraction of OH radical increases with the increase of the equivalence ratio, and the increase of OH radical near the inert wall is larger than that of the active wall. As the flow rate increases, the disturbance increases, and the combustion reaction becomes more intense, resulting in an increase in the temperature and the mass fraction of OH radicals. The mass fraction of H, O, OH, and CH3 radicals in the inert wall was slightly higher than that in the active wall, in which the peak mass fraction of CH3 radical appeared at the axial position closest to the entrance, while the other three radicals reached the peak at about the same axial position. This study provides a reference for combustion stability in microcombustors.
- Open Access
- 21 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 160
Integrated Microfluidic Chip Technology for Copper Ion Detection Using an All-Solid-State Ion-Selective Electrode
This study involved the preparation of an all-solid-state ion-selective electrode (ASS-ISE) with copper and a poly(3,4-ethylenedioxythiophene) and polystyrene sulfonate (PEDOT/PSS) conversion layer through electrode deposition. The morphology of the PEDOT/PSS film was characterized, and the performance of the copper ion-selective film was optimized. Additionally, a microfluidic chip for the ASS-ISE with copper was designed and prepared. An integrated microfluidic chip test system with an ASS-ISE was developed using a self-constructed potential detection device. The accuracy of the system was validated through comparison testing with atomic absorption spectrophotometry (AAS). The experimental findings indicate that the relative standard deviation (RSD) of the integrated ASS-ISE with the copper microfluidic chip test system is 4.54%, as compared to the industry standard method. This value complies with the stipulated requirement of an RSD ≤ 5% in DL/T 955-2016.
- 21 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 160
Open AccessIntegrated Microfluidic Chip Technology for Copper Ion Detection Using an All-Solid-State Ion-Selective Electrode
This study involved the preparation of an all-solid-state ion-selective electrode (ASS-ISE) with copper and a poly(3,4-ethylenedioxythiophene) and polystyrene sulfonate (PEDOT/PSS) conversion layer through electrode deposition. The morphology of the PEDOT/PSS film was characterized, and the performance of the copper ion-selective film was optimized. Additionally, a microfluidic chip for the ASS-ISE with copper was designed and prepared. An integrated microfluidic chip test system with an ASS-ISE was developed using a self-constructed potential detection device. The accuracy of the system was validated through comparison testing with atomic absorption spectrophotometry (AAS). The experimental findings indicate that the relative standard deviation (RSD) of the integrated ASS-ISE with the copper microfluidic chip test system is 4.54%, as compared to the industry standard method. This value complies with the stipulated requirement of an RSD ≤ 5% in DL/T 955-2016.