Veronica Lombardo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Veronica Lombardo has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Cesare Mariotti
Eye Clinic, Department of Experimental and Clinical Medicine, Polytechnic University of Marche, 60126 Ancona, Italy
1 shared publication - Clara Rizzo
Department of Neurosciences, Psychology, Drug Research, and Child Health, Eye Clinic, University of Florence, AOU Careggi, 50139 Florence, Italy
1 shared publication - Daniela Fruttini
Department of Medicine and Surgery, University of Perugia, 06129 Perugia, Italy
1 shared publication - Edoardo Midena
Department of Neuroscience-Ophthalmology, University of Padova, 35128 Padova, Italy
1 shared publication - Jay Chhablani
UPMC Eye Center, University of Pittsburgh, Pittsburgh, Pennsylvania
1 shared publication - Lorenzo Mangoni
Eye Clinic, Department of Experimental and Clinical Medicine, Polytechnic University of Marche, 60126 Ancona, Italy
1 shared publication
Latest Publications
- Open Access
- 22 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 628
Novel Artificial Intelligence-Based Assessment of Imaging Biomarkers in Full-Thickness Macular Holes: Preliminary Data from a Pivotal Trial
Artificial intelligence (AI)- and deep learning (DL)-based systems have shown significant progress in the field of macular disorders, demonstrating high performance in detecting retinal fluid and assessing anatomical changes during disease progression. This study aimed to validate an AI algorithm for identifying and quantifying prognostic factors in visual recovery after macular hole (MH) surgery by analyzing major optical coherence tomography (OCT) biomarkers. This study included 20 patients who underwent vitrectomy for a full-thickness macular hole (FTMH). The mean diameter of the FTMH was measured at 285.36 ± 97.4 μm. The preoperative best-corrected visual acuity (BCVA) was 0.76 ± 0.06 logMAR, improving to 0.38 ± 0.16 postoperatively, with a statistically significant difference (p = 0.001). AI software was utilized to assess biomarkers, such as intraretinal fluid (IRF) and subretinal fluid (SRF) volume, external limiting membrane (ELM) and ellipsoid zone (EZ) integrity, and retinal hyperreflective foci (HRF). The AI analysis showed a significant decrease in IRF volume, from 0.08 ± 0.12 mm3 preoperatively to 0.01 ± 0.01 mm3 postoperatively. ELM interruption improved from 79% ± 18% to 34% ± 37% after surgery (p = 0.006), whereas EZ interruption improved from 80% ± 22% to 40% ± 36% (p = 0.007) postoperatively. Additionally, the study revealed a negative correlation between preoperative IRF volume and postoperative BCVA recovery, suggesting that greater preoperative fluid volumes may hinder visual improvement. The integrity of the ELM and EZ was found to be essential for postoperative visual acuity improvement, with their disruption negatively impacting visual recovery. The study highlights the potential of AI in quantifying OCT biomarkers for managing MHs and improving patient care.
- 22 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (2) , 628
Open AccessNovel Artificial Intelligence-Based Assessment of Imaging Biomarkers in Full-Thickness Macular Holes: Preliminary Data from a Pivotal Trial
Artificial intelligence (AI)- and deep learning (DL)-based systems have shown significant progress in the field of macular disorders, demonstrating high performance in detecting retinal fluid and assessing anatomical changes during disease progression. This study aimed to validate an AI algorithm for identifying and quantifying prognostic factors in visual recovery after macular hole (MH) surgery by analyzing major optical coherence tomography (OCT) biomarkers. This study included 20 patients who underwent vitrectomy for a full-thickness macular hole (FTMH). The mean diameter of the FTMH was measured at 285.36 ± 97.4 μm. The preoperative best-corrected visual acuity (BCVA) was 0.76 ± 0.06 logMAR, improving to 0.38 ± 0.16 postoperatively, with a statistically significant difference (p = 0.001). AI software was utilized to assess biomarkers, such as intraretinal fluid (IRF) and subretinal fluid (SRF) volume, external limiting membrane (ELM) and ellipsoid zone (EZ) integrity, and retinal hyperreflective foci (HRF). The AI analysis showed a significant decrease in IRF volume, from 0.08 ± 0.12 mm3 preoperatively to 0.01 ± 0.01 mm3 postoperatively. ELM interruption improved from 79% ± 18% to 34% ± 37% after surgery (p = 0.006), whereas EZ interruption improved from 80% ± 22% to 40% ± 36% (p = 0.007) postoperatively. Additionally, the study revealed a negative correlation between preoperative IRF volume and postoperative BCVA recovery, suggesting that greater preoperative fluid volumes may hinder visual improvement. The integrity of the ELM and EZ was found to be essential for postoperative visual acuity improvement, with their disruption negatively impacting visual recovery. The study highlights the potential of AI in quantifying OCT biomarkers for managing MHs and improving patient care.