SKShun Kamiya

Shun Kamiya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shun Kamiya has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Rotating waveplate Stokes polarimeter using anisotropic transmittance in waveplate

    by Ryota Imazawa, Shun Kamiya, Yoshihiko Nunoya

    One of well-known polarization measurement techniques is a rotating waveplate Stokes polarimeter. This technique modulates the polarization state by rotating a quarter waveplate, and the polarization state can be identified from the second and the fourth harmonics of the modulated detector signal. This study presents a new signal model and a new calibration method for the rotating waveplate Stokes polarimeter using an anisotropic-transmittance quarter waveplate. It was found that anisotropic transmittance enables identification of the light intensity and the degree of polarization without measuring the DC (direct current) component of the intensity of the modulated polarized light. In addition, anisotropic transmittance enables the calibration of the rotating waveplate Stokes polarimeter by using only linearly polarized light. The experiment was carried out to demonstrate the measurement capability of the polarimeter using the anisotropic-transmittance waveplate and the 95% confidence interval of the error was 0%–1.9%.


  • Design and development of a single-laser 2D Thomson scattering measurement system for TS-6 merging tokamak/magnetic reconnection experiments

    by S. Kamiya, H. Yamaguchi, J. Kim, M. Akimitsu, S. Himeno, H. Tanabe, K. Narihara, Y. Ono

    Nd:YAG Thomson scattering diagnostics is reliable measurement of electron temperature and density, but its 2D extension conventionally needs as many polychromators as measuring points and as many lasers as measuring paths. To reduce the numbers and costs, we designed and developed a single-laser 2D measurement system by use of multiple reflection and time-of-flight of laser light. A single laser pulse reflects between mirrors on both sides of the vacuum vessel and makes seven round trips, which enables measurement at m × 7 points with only m polychromators and a single laser. Here, we present the design to satisfy the resolution required for TS-6 merging tokamak and magnetic reconnection experiments and the system development, especially the time-separation of scattered light signals from different points with time-of-flight delays. The measured Thomson scattering signals from 7 × 2 points and the measured Raman scattered signals from points in four laser paths indicate the feasibility of Thomson scattering measurement at m × 4 points.


  • Open Access

    Correction to: A Cost-Effective Polychromator with a Single Interference Filter for Thomson Scattering Diagnostics

    by Shun Kamiya, Haruka Yamaguchi, Jungkyun Kim, Shun-Ichi Himeno, Hiroshi Tanabe, Yasushi Ono

  • Open Access

    A Cost-Effective Polychromator with a Single Interference Filter for Thomson Scattering Diagnostics

    by Shun Kamiya, Haruka Yamaguchi, Jungkyun Kim, Shun-Ichi Himeno, Hiroshi Tanabe, Yasushi Ono

    We propose a cost-effective polychromator with a single interference filter, because interference filters account for large parts of polychromator costs in the conventional Thomson scattering diagnostics with a Nd:YAG laser. Since the interference filters are used to transmit the scattered light in a specific wavelength range, one polychromator tends to have as many interference filters as its spectral channels, which makes high-resolution measurement with a number of polychromators expensive. However, we can save the number of interference filters and thus their costs by reentering reflected light from an interference filter into the same filter at different angles. This is possible, because the larger angle of incidence on the interference filter makes the wavelength of the transmitted light shorter. We measured dependence of transmitted wavelengths on the angles of incidence on one interference filter custom-ordered to transmit 1059 nm and developed the cost-effective polychromator using this dependence. The developed polychromator with a single filter successfully separated three different spectral channels (1043.2, 1051.9, and 1058.4 nm), enabling us to realize the cost-effective Thomson scattering diagnostics.