Moe Akimitsu
Moe Akimitsu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Federico A. D’iSa
Consorzio RFX (CNR, ENEA, INFN, Acciaierie Venete SpA, Universitá di Padova)
4 shared publications - Yoshiaki Ohtani
National Institutes for Quantum Science and Technology , 801-1 Mukoyama, Nakai, Ibaraki 311-0193
4 shared publications - Hiroshi Tojo
National Institutes for Quantum Science and Technology, 801-1 Mukoyama, Naka, Ibaraki 311-0193, Japan
3 shared publications - Roberto Pasqualotto
Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4
3 shared publications - Sorin Soare
The National Institute for Cryogenics and Isotopic Technology, Ramnicu Valcea, Romania
3 shared publications - A. Fassina
Consorzio RFX, Corso Stati Uniti 4, 35127 Padova, Italy
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 5518-5522
Expected Performance of the JT-60SA Edge Thomson Scattering Diagnostic in OP2
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (10) , 5518-5522
Expected Performance of the JT-60SA Edge Thomson Scattering Diagnostic in OP2
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , C10017
Laser-aided diagnostics of JT-60SA
JT-60SA is currently the world's largest superconducting tokamak. It accelerates the realization of fusion energy by supporting ITER exploitation and complementing it in addressing key physics and engineering issues for DEMO reactors. The main targets of JT-60SA are breakeven-equivalent high-temperature deuterium plasmas and high- β steady-state plasmas. To achieve these goals, laser-aided diagnostics with high spatial resolution are essential for detailed physics studies. In Operation Phase 1, a tangential single-chord two-color CO 2 laser interferometer was installed. The data acquisition and processing system featured fringe-jump detection and real-time processing, enabling density feedback control. In the upcoming operational phases, a CO 2 laser polarimeter and Thomson scattering diagnostics will be implemented in Operation Phase 2, followed by the installation of phase-contrast imaging in Operation Phase 3. This paper summarizes the measurement results from the first operational phase and outlines the design and current status of the other three diagnostics.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , C10017
Laser-aided diagnostics of JT-60SA
JT-60SA is currently the world's largest superconducting tokamak. It accelerates the realization of fusion energy by supporting ITER exploitation and complementing it in addressing key physics and engineering issues for DEMO reactors. The main targets of JT-60SA are breakeven-equivalent high-temperature deuterium plasmas and high- β steady-state plasmas. To achieve these goals, laser-aided diagnostics with high spatial resolution are essential for detailed physics studies. In Operation Phase 1, a tangential single-chord two-color CO 2 laser interferometer was installed. The data acquisition and processing system featured fringe-jump detection and real-time processing, enabling density feedback control. In the upcoming operational phases, a CO 2 laser polarimeter and Thomson scattering diagnostics will be implemented in Operation Phase 2, followed by the installation of phase-contrast imaging in Operation Phase 3. This paper summarizes the measurement results from the first operational phase and outlines the design and current status of the other three diagnostics.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Collection optics of JT-60SA edge Thomson scattering diagnostic
The mission of the JT-60SA project is to complement ITER’s capabilities by addressing the fundamental physics and engineering challenges necessary to develop a practical and reliable fusion power plant. Diagnostics play a pivotal role in achieving this mission, especially the Thomson Scattering (TS) diagnostic systems developed by a collaborative Japan–EU team. The edge Thomson scattering of JT-60SA is tailored to measure the low field side outer region of the plasma, in particular, to resolve the electron temperature Te and density ne. The collection optics of the edge TS system have a critical role in meeting the required field of view and spatial resolution despite the limited space. This work presents a comprehensive optomechanical design of the optics assembly, whose main features are telecentricity and compactness, highlighting its capabilities. The tests undertaken to verify its performance: focal plane identification, thermal cycle, and magnification, are described.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Collection optics of JT-60SA edge Thomson scattering diagnostic
The mission of the JT-60SA project is to complement ITER’s capabilities by addressing the fundamental physics and engineering challenges necessary to develop a practical and reliable fusion power plant. Diagnostics play a pivotal role in achieving this mission, especially the Thomson Scattering (TS) diagnostic systems developed by a collaborative Japan–EU team. The edge Thomson scattering of JT-60SA is tailored to measure the low field side outer region of the plasma, in particular, to resolve the electron temperature Te and density ne. The collection optics of the edge TS system have a critical role in meeting the required field of view and spatial resolution despite the limited space. This work presents a comprehensive optomechanical design of the optics assembly, whose main features are telecentricity and compactness, highlighting its capabilities. The tests undertaken to verify its performance: focal plane identification, thermal cycle, and magnification, are described.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , C04011
Performance of JT-60SA Thomson Scattering data analysis system
We have developed signal processing routines for the Thomson Scattering measurement, which is planned for use in the next campaign of the JT-60SA large-scale tokamak experiment. This paper provides the data analysis system and its performance evaluated in terms of computation time and error. The sequential routine of determining the scattered light intensity from a simulated signal, including noise data from a 1 Gs/s high-speed sampling digitizer, and determining the electron temperature and density was tested for the first time on an actual machine. The data analysis system ensures that electron temperature and density can be calculated with reasonable relative errors and within a realistic time frame for operations on JT-60SA.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , C04011
Performance of JT-60SA Thomson Scattering data analysis system
We have developed signal processing routines for the Thomson Scattering measurement, which is planned for use in the next campaign of the JT-60SA large-scale tokamak experiment. This paper provides the data analysis system and its performance evaluated in terms of computation time and error. The sequential routine of determining the scattered light intensity from a simulated signal, including noise data from a 1 Gs/s high-speed sampling digitizer, and determining the electron temperature and density was tested for the first time on an actual machine. The data analysis system ensures that electron temperature and density can be calculated with reasonable relative errors and within a realistic time frame for operations on JT-60SA.
- 1 January 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (01) , C01043
Design and development of a single-laser 2D Thomson scattering measurement system for TS-6 merging tokamak/magnetic reconnection experiments
Nd:YAG Thomson scattering diagnostics is reliable measurement of electron temperature and density, but its 2D extension conventionally needs as many polychromators as measuring points and as many lasers as measuring paths. To reduce the numbers and costs, we designed and developed a single-laser 2D measurement system by use of multiple reflection and time-of-flight of laser light. A single laser pulse reflects between mirrors on both sides of the vacuum vessel and makes seven round trips, which enables measurement at m × 7 points with only m polychromators and a single laser. Here, we present the design to satisfy the resolution required for TS-6 merging tokamak and magnetic reconnection experiments and the system development, especially the time-separation of scattered light signals from different points with time-of-flight delays. The measured Thomson scattering signals from 7 × 2 points and the measured Raman scattered signals from points in four laser paths indicate the feasibility of Thomson scattering measurement at m × 4 points.
- 1 January 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (01) , C01043
Design and development of a single-laser 2D Thomson scattering measurement system for TS-6 merging tokamak/magnetic reconnection experiments
Nd:YAG Thomson scattering diagnostics is reliable measurement of electron temperature and density, but its 2D extension conventionally needs as many polychromators as measuring points and as many lasers as measuring paths. To reduce the numbers and costs, we designed and developed a single-laser 2D measurement system by use of multiple reflection and time-of-flight of laser light. A single laser pulse reflects between mirrors on both sides of the vacuum vessel and makes seven round trips, which enables measurement at m × 7 points with only m polychromators and a single laser. Here, we present the design to satisfy the resolution required for TS-6 merging tokamak and magnetic reconnection experiments and the system development, especially the time-separation of scattered light signals from different points with time-of-flight delays. The measured Thomson scattering signals from 7 × 2 points and the measured Raman scattered signals from points in four laser paths indicate the feasibility of Thomson scattering measurement at m × 4 points.
- Open Access
- 7 June 2021
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 16, 1202078
Development of Glass-Tube-Pair Type Doppler Probe Array for 1D Profile Measurement of Two Component Ion-Flow Vector
We developed a new glass-tube-pair type Doppler probe array for 1D ion velocity vector and temperature measurement. It needs just two parallel glass-tube insertion, realizing low plasma perturbation and 1D ion flow vector measurement on a single discharge. Using four mirrors and optical fibers for one measurement point, this system can measure ion local light emissions of each measurement volume from four different directions, enabling us to measure local ion flow vector and temperature. All set of mirrors and optical fibers are aligned in the two parallel glass tubes for 1D measurement by a single discharge. This system measured successfully ion outflow speed of two merging tokamak plasmas, about 80% of poloidal Alfvén speed in agreement with recent reconnection experiments and theory.
- 7 June 2021
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 16, 1202078
Open AccessDevelopment of Glass-Tube-Pair Type Doppler Probe Array for 1D Profile Measurement of Two Component Ion-Flow Vector
We developed a new glass-tube-pair type Doppler probe array for 1D ion velocity vector and temperature measurement. It needs just two parallel glass-tube insertion, realizing low plasma perturbation and 1D ion flow vector measurement on a single discharge. Using four mirrors and optical fibers for one measurement point, this system can measure ion local light emissions of each measurement volume from four different directions, enabling us to measure local ion flow vector and temperature. All set of mirrors and optical fibers are aligned in the two parallel glass tubes for 1D measurement by a single discharge. This system measured successfully ion outflow speed of two merging tokamak plasmas, about 80% of poloidal Alfvén speed in agreement with recent reconnection experiments and theory.