ZQZiling Qiao

Ziling Qiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ziling Qiao has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Symmetric-anchored transport-of-intensity phase retrieval with adaptive gradient refinement

    by Zining Ouyang, Ziyang Li, Ziling Qiao, Longhui Fu, Hang Chen, Yutong Li, Shutian Liu, Zhengjun Liu

    Quantitative phase imaging via the transport-of-intensity equation (TIE) enables label-free phase measurement, but its accuracy degrades under large defocus, where the underlying nonlinearity becomes pronounced. We propose SA-RAdam, a symmetric-anchored, rectified-Adam-refined framework for high-fidelity TIE phase retrieval. A symmetric two-plane architecture yields a second-order accurate derivative prior at a virtual mid-plane, anchored to the reference plane via angular-spectrum propagation. An adjoint gradient of the forward model, combined with rectified adaptive momentum and line search, then recovers nonlinear high-frequency phase details typically lost in linear solvers. Simulations and experiments on binary and biological phase targets show consistent convergence, elimination of boundary overshoot, and RMSE reductions of over 60% relative to existing iterative solvers, substantially extending the practical defocus range of TIE-based phase retrieval.

  • Spectral-Routed Mixture of Experts for High-Fidelity Complex-Field Measurement in Single-Frame Lens-Free On-Chip Microscopy

    by Sida Gao, Ziyang Li, Pengcheng Jia, Longhui Fu, Ziling Qiao, Yutong Li, Shutian Liu, Zhengjun Liu

    Single-frame lens-free on-chip microscopy (LFOM) offers a compact and cost-effective solution for biomedical diagnostics and micro/nanoscale inspection but suffers from severe twin-image artifacts and frequency-dependent degradation due to numerical aperture (NA) limitations. Existing reconstruction methods often neglect the heterogeneous frequency sensitivity of LFOM and fail to explicitly suppress artifacts, leading to suboptimal complex-field measurement quality. To address these challenges, we propose SEMNet, a spectral-expert measurement network that introduces frequency-aware modeling into single-frame LFOM reconstruction. Specifically, SEMNet transforms captured holograms into polar Fourier space, partitions them into directional subbands, and adaptively routes each subband via a soft top-k gating mechanism to lightweight expert networks specialized for low-, mid-, and high-frequency restoration. A physics-consistent loss jointly enforces complex-field fidelity, Fresnel-likelihood consistency, twin-image suppression, and spectral load balancing, thereby aligning the reconstruction objective with physical imaging principles. Extensive experiments on 404 high-resolution hologram–complex field pairs from seven types of biological tissues demonstrate that SEMNet improves peak signal-to-noise ratio by up to 1.7 dB over strong single-frame baselines, with statistically significant gains in structural similarity indices (p < 0.001). SEMNet restores high-frequency textures while suppressing NA-boundary artifacts. It delivers 47.1 FPS end-to-end inference with 100× fewer parameters than a representative CNN baseline and 5× fewer MACs than a representative Transformer baseline, highlighting a frequency-structured, physics-aligned design for efficient LFOM.


  • Efficient and high-fidelity reconstruction for structured illumination microscopy via spectrum modulation

    by Yiran Wang, Ziyang Li, Yu Ji, Yutong Li, Xuyang Zhou, Guancheng Huang, Ziling Qiao, Zhengjun Liu, Shutian Liu

  • Wide‐Field, Artifact‐Suppressed Lensless Microscopy Via Feature‐Agnostic Autofocus and Multi‐Target Separable Phase Retrieval

    by Ziyang Li, Xuyang Zhou, Sida Gao, Guancheng Huang, Ziling Qiao, Zhengyu Wu, Yutong Li, Shutian Liu, Zhengjun Liu

    Lensless on‐chip microscopy (LOCM) is a promising technique for high‐throughput, label‐free imaging. However, its practical implementation remains constrained by sensitivity to variations in sample‐sensor distance and cumulative noise during reconstruction. Existing autofocus and phase retrieval algorithms fail when dealing with non‐planar samples and environmental disturbances. A wide‐field, artifact‐suppressed lensless imaging framework with natural support constraints is proposed, which integrates segment‐dependent lateral registration, feature‐agnostic autofocus, and multi‐target separable phase retrieval. The proposed complex field correction scheme effectively addresses diffraction scale distortion and sensor trajectory deviations while mitigating the dependence of autofocus on sample‐specific image features. The phase retrieval process is further enhanced via a multi‐objective stochastic gradient descent algorithm, which enables effective noise separation without compromising resolution. Experimental validations with diverse samples demonstrate significant performance improvements, achieving pixel‐super‐resolved imaging with a full field of view (FOV) of 28.6 , an imaging depth exceeding 80 , and a half‐pitch resolution of 775 nm, corresponding to a 2.15‐fold improvement in spatial resolution beyond the Nyquist–Shannon sampling limit. Furthermore, the proposed method demonstrates strong compatibility with coherent diffraction imaging (CDI), highlighting its broader applicability. The proposed method improves the versatility of lensless microscopy, eliminates reliance on stringent calibration, and provides a robust solution for high‐throughput computational imaging.


  • Fast autofocusing of recorded planes by salient feature region for coherent diffraction imaging

    by Xuyang Zhou, Ziyang Li, Ziling Qiao, Yiran Wang, Guancheng Huang, Dazhao Chi, Xiaomei Li, Shutian Liu, Zhengjun Liu

    In multi‐distance coherent diffraction imaging, the task of distance calculation for multi‐diffraction images is cumbersome. The information features are hard‐to‐extract and the region of interest extraction algorithms are difficult to be adopted. A universal salient feature region selection algorithm by using the area with the highest density of corners is proposed to extract the most representative feature region. In addition, equally spaced recording modes and mismatched diffraction distances will result in system noise and destroy image quality. The polydirectional maximum gradient is offered as a sharpness criterion to weigh a quantitative feature for the final pattern. A fast, sensitive, and high‐accuracy autofocusing and sample reconstruction can be achieved using only a small number of images while ensuring that morphological properties and quantification of the reconstructions are not compromised. The proposed method is promising for biological and medical dynamic observations for computational imaging systems.