PKPaul Kreczanik

Paul Kreczanik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul Kreczanik has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Étude de la fiabilité et du vieillissement d’un système de stockage par supercondensateurs pour l’alimentation partielle et ponctuelle d’un trolleybus grâce à la récupération de l'énergie de freinage : approche du composant au système de stockage

    by Paul Kreczanik

    Le premier objectif du projet HYBUS est d’intégrer un système de stockage par supercondensateurs dans un trolleybus permettant la récupération de son énergie de freinage afin d’assurer la continuité de l’alimentation des systèmes électriques embarqués. A terme un système de stockage plus conséquent est prévu pour permettre au trolleybus une autonomie de quelques mètres. Notre travail étudie la durée de vie de ce système. Plusieurs tests de vieillissement accéléré sur les supercondensateurs ont été mis en place au laboratoire AMPERE. Ces essais ont mis en évidence que le cyclage engendrait une forte accélération de la diminution de la capacité et de l’augmentation de la résistance série. Cependant, ces variations sont partiellement réversibles lors des phases de repos où une régénération s’opère. Une méthode se basant sur les dégradations observées en cours d’utilisation et les dégradations demeurant après régénération, a permis une mise en équation de l’évolution des paramètres internes des supercondensateurs. Un test d’endurance de systèmes complets de stockage a aussi été réalisé au laboratoire. Les résultats expérimentaux montrent une hétérogénéité du vieillissement due à l’existence d’importants gradients de température entre les composants. De ce fait, une nouvelle méthodologie d’équilibrage visant à égaliser les durées de vie de chacun des supercondensateurs a été mise au point. L’étude a donc contribué à une meilleure compréhension et évaluation du vieillissement des supercondensateurs dans le but d’améliorer la durée de vie de système de stockage de ce type. Une méthode est proposée pour estimer les dégradations en fonction des facteurs majeurs du vieillissement.

  • Open Access

    An Air Over-Stoichiometry Dependent Voltage Model for HT-PEMFC MEAs

    by Sylvain Rigal, Amine Jaafar, Christophe Turpin, Théophile Hordé, Jean-Baptiste Jollys, Paul Kreczanik

    In this work, three commercially available Membrane Electrode Assemblies (MEAs) from Advent Technology Inc. and Danish Power Systems, developed for a use in High Temperature Proton Exchange Membrane Fuel Cell (HT-PEMFC), were tested under various Operating Conditions (OCs): over-stoichiometry of hydrogen gas (1.05, 1.2, 1.35), over-stoichiometry of air gas (1.5, 2, 2.5), gas oxidant (O2 or air) and temperature (140 °C, 160 °C, 180 °C). For each set of operating conditions, a polarization curve (V–I curve) was performed. A semi-empirical and macroscopic (0D) model of the fuel cell voltage was established in steady state conditions in order to model some of these experimental data. The proposed parameterization approach for this model (called here the “multi-VI” approach) is based on the sensitivity to the operating conditions specific to each involved physicochemical phenomenon. According to this method, only one set of parameters is used in order to model all the experimental curves (optimization is performed simultaneously on all curves). A model depending on air over-stoichiometry was developed. The main objective is to validate a simple (0D) and fast-running model that considers the impact of air over-stoichiometry on cell voltage regarding all commercially available MEAs. The obtained results are satisfying with AdventPBI MEA and Danish Power Systems MEA: an average error less than 1.5% and a maximum error around 15% between modelled and measured voltages with only nine parameters to identify. However, the model was not as adapted to Advent TPS® MEA: average error and maximum error around 4% and 21%, respectively. Most of the obtained parameters appear consistent regardless of the OCs. The predictability of the model was also validated in the explored domain during the sensibility study with an interesting accuracy for 27 OCs after being trained on only nine curves. This is attractive for industrial application, since it reduces the number of experiments, hence the cost of model development, and is potentially applicable to all commercial HT-PEMFC MEAs.


  • Open Access

    Steady-State Voltage Modelling of a HT-PEMFC under Various Operating Conditions

    by Sylvain Rigal, Amine Jaafar, Christophe Turpin, Théophile Hordé, Jean-Baptiste Jollys, Paul Kreczanik

    In this work, a commercially available membrane electrode assembly from Advent Technology Inc., developed for use in high-temperature proton exchange membrane fuel cells, was tested under various operating conditions (OCs) according to a sensibility study with three OCs varying on three levels: hydrogen gas over-stoichiometry (1.05, 1.2, 1.35), air gas over-stoichiometry (1.5, 2, 2.5), and temperature (140 °C, 160 °C, 180 °C). A polarization curve (V-I curve) was performed for each set of operating conditions (27 V-I curves in total). A semi-empirical and macroscopic (0D) model of the cell voltage was developed in steady-state conditions to model these experimental data. With the proposed parameterization approach, only one set of parameters is used in order to model all the experimental curves (simultaneous optimization with 27 curves). Thus, an air over-stoichiometry-dependent model was developed. The obtained results are promising between 0.2 and 0.8 A·cm−2: an average error less than 1.5% and a maximum error around 7% between modeled and measured voltages with only 9 parameters to identify. The obtained parameters appear consistent, regardless of the OCs. The proposed approach with only one set of parameters seems to be an interesting way to converge towards the uniqueness of consistent parameters.