NSNikolaus-Peter Schumann

Nikolaus-Peter Schumann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nikolaus-Peter Schumann has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Christoph Anders

    Affiliation Division of Motor Research, Pathophysiology and Biomechanics, Experimental Trauma Surgery, Department for Hand, Reconstructive, and Trauma Surgery, Jena University Hospital, Friedrich-Schiller-University Jena, Jena, Germany

    1 shared publication
  • Hartmut Witte

    Group of Biomechatronics, Fachgebiet Biomechatronik, Technische Universität Ilmenau, D-98693 Ilmenau, Germany

    1 shared publication
  • Stefan Kreipe

    FB Motorik und Pathophysiologie, Klinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinikum Jena, 07740 Jena, Germany

    1 shared publication
  • Thomas Helbig

    Fachgebiet Biomechatronik, Institut für Mechatronische Systemintegration, Fakultät für Maschinenbau, Technische Universität Ilmenau, 98693 Ilmenau, Germany

    1 shared publication

Latest Publications

  • Open Access

    Comparison of sEMG Onset Detection Methods for Occupational Exoskeletons on Extensive Close-to-Application Data

    by Stefan Kreipe, Thomas Helbig, Hartmut Witte, Nikolaus-Peter Schumann, Christoph Anders

    The design of human-machine interfaces of occupational exoskeletons is essential for their successful application, but at the same time demanding. In terms of information gain, biosensoric methods such as surface electromyography (sEMG) can help to achieve intuitive control of the device, for example by reduction of the inherent time latencies of a conventional, non-biosensoric, control scheme. To assess the reliability of sEMG onset detection under close to real-life circumstances, shoulder sEMG of 55 healthy test subjects was recorded during seated free arm lifting movements based on assembly tasks. Known algorithms for sEMG onset detection are reviewed and evaluated regarding application demands. A constant false alarm rate (CFAR) double-threshold detection algorithm was implemented and tested with different features. Feature selection was done by evaluation of signal-to-noise-ratio (SNR), onset sensitivity and precision, as well as timing error and deviation. Results of visual signal inspection by sEMG experts and kinematic signals were used as references. Overall, a CFAR algorithm with Teager-Kaiser-Energy-Operator (TKEO) as feature showed the best results with feature SNR = 14.48 dB, 91% sensitivity, 93% precision. In average, sEMG analysis hinted towards impending movements 215 ms before measurable kinematic changes.