Helena Mehtonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Helena Mehtonen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jari Kangas
TAUCHI Research Center, Tampere University, Tampere, Finland
4 shared publications - Jorma Järnstedt
Department of Radiology, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, Tampere, Finland
4 shared publications - Roope Raisamo
Tampere University, Tampere, Finland
4 shared publications - Kimmo Ronkainen
TAUCHI Research Center, Faculty of Information Technology and Communication Sciences, Tampere University, 33100 Tampere, Finland
3 shared publications - Arnon Charuakkra
Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University, Chiang Mai 50200, Thailand
2 shared publications - Irina Rinta-Kiikka
Department of Radiology, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, 33250 Tampere, Finland
2 shared publications
Latest Publications
- Open Access
- 7 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2493
Immersive Virtual Reality for 3D Cephalometric Landmarking Across Low-Dose and Ultra-Low-Dose CBCT: A Pilot Comparison with a Conventional Computer Interface
Background: Three-dimensional cephalometric landmarking provides the spatial reference framework for computer-aided surgical simulation in craniomaxillofacial (CMF) surgery. Conventional workflows rely on two-dimensional computer interfaces (CIs), yet imaging data are inherently volumetric, and repeated CBCT imaging creates pressure to minimise patient radiation exposure. Immersive virtual reality (VR) offers a more intuitive environment for spatial tasks, yet the feasibility of ultra-low-dose (uLD) protocols for cephalometric landmarking in CI and VR remains unevaluated. This pilot study evaluated accuracy, reproducibility and workload across low-dose (LD) and uLD CBCT protocols in both environments. Methods: Four CMF radiologists placed ten 3D cephalometric landmarks on 20 CBCT datasets across three rounds. Round 1 used deep learning-predicted coordinates as ground truth. Rounds 2–3 assessed blind reproducibility. Workload was evaluated using the NASA Task Load Index. Results: Median Round 1 accuracy was 1.00 mm in both environments; mean CI accuracy was 1.05 mm and mean VR accuracy was 2.03 mm after outlier exclusion. Log analysis identified controller slips and software logging errors as a primary VR outlier source (22/793, 2.77%). Reproducibility was higher in CIs; VR medians remained clinically relevant. Dose level had no meaningful effect. The NASA-TLX showed decreasing VR workload across sessions, with AI-guided landmarking associated with the lowest mental demand. Conclusions: VR-based landmarking is feasible: its median accuracy was comparable to that of CIs and radiologists responded positively. Reproducibility was lower in VR, attributable to software constraints rather than the visualisation modality. The uLD protocol performed comparably to LD, supporting dose optimisation. Integration of AI assistance within VR represents the most promising direction for further development.
- 7 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2493
Open AccessImmersive Virtual Reality for 3D Cephalometric Landmarking Across Low-Dose and Ultra-Low-Dose CBCT: A Pilot Comparison with a Conventional Computer Interface
Background: Three-dimensional cephalometric landmarking provides the spatial reference framework for computer-aided surgical simulation in craniomaxillofacial (CMF) surgery. Conventional workflows rely on two-dimensional computer interfaces (CIs), yet imaging data are inherently volumetric, and repeated CBCT imaging creates pressure to minimise patient radiation exposure. Immersive virtual reality (VR) offers a more intuitive environment for spatial tasks, yet the feasibility of ultra-low-dose (uLD) protocols for cephalometric landmarking in CI and VR remains unevaluated. This pilot study evaluated accuracy, reproducibility and workload across low-dose (LD) and uLD CBCT protocols in both environments. Methods: Four CMF radiologists placed ten 3D cephalometric landmarks on 20 CBCT datasets across three rounds. Round 1 used deep learning-predicted coordinates as ground truth. Rounds 2–3 assessed blind reproducibility. Workload was evaluated using the NASA Task Load Index. Results: Median Round 1 accuracy was 1.00 mm in both environments; mean CI accuracy was 1.05 mm and mean VR accuracy was 2.03 mm after outlier exclusion. Log analysis identified controller slips and software logging errors as a primary VR outlier source (22/793, 2.77%). Reproducibility was higher in CIs; VR medians remained clinically relevant. Dose level had no meaningful effect. The NASA-TLX showed decreasing VR workload across sessions, with AI-guided landmarking associated with the lowest mental demand. Conclusions: VR-based landmarking is feasible: its median accuracy was comparable to that of CIs and radiologists responded positively. Reproducibility was lower in VR, attributable to software constraints rather than the visualisation modality. The uLD protocol performed comparably to LD, supporting dose optimisation. Integration of AI assistance within VR represents the most promising direction for further development.
- Open Access
- 17 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (10) , 5007
Influence of Cone Beam Computed Tomography Radiation Dose on Image Quality and Usability in Virtual Reality and Traditional Computer Interfaces
Computer-assisted surgical simulation (CASS) in craniomaxillofacial (CMF) surgery is traditionally performed using a computer interface (CI) with a two-dimensional monitor, while the adoption of immersive virtual reality (VR) remains limited. This study examined how low-dose (LD) and high-dose (HD) cone beam computed tomography (CBCT) imaging modes influence image quality and usability across both CI and VR environments. Five CMF radiologists rated CBCT views and 3D-segmented models on a 0–4 Likert scale, and intra- and interobserver agreement was calculated. VR usability was further assessed using the NASA Task Load Index and follow-up interviews. LD imaging performed comparably to HD in both interfaces, with slightly higher scores for CBCT views in LD mode. For 3D models, HD scored marginally higher in CI, whereas LD performed slightly better in VR. Observer agreement ranged from fair to excellent, and VR demonstrated reliability like CI. NASA-TLX results indicated reductions in mental and temporal demand, along with decreased effort and frustration during VR use, suggesting diminishing cognitive and emotional strain over time. In this pilot study, the findings suggest that LD CBCT may be feasible for selected CMF CASS applications and that VR offers an immersive and user-friendly alternative without compromising diagnostic reliability, supporting its potential role in future surgical planning.
- 17 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (10) , 5007
Open AccessInfluence of Cone Beam Computed Tomography Radiation Dose on Image Quality and Usability in Virtual Reality and Traditional Computer Interfaces
Computer-assisted surgical simulation (CASS) in craniomaxillofacial (CMF) surgery is traditionally performed using a computer interface (CI) with a two-dimensional monitor, while the adoption of immersive virtual reality (VR) remains limited. This study examined how low-dose (LD) and high-dose (HD) cone beam computed tomography (CBCT) imaging modes influence image quality and usability across both CI and VR environments. Five CMF radiologists rated CBCT views and 3D-segmented models on a 0–4 Likert scale, and intra- and interobserver agreement was calculated. VR usability was further assessed using the NASA Task Load Index and follow-up interviews. LD imaging performed comparably to HD in both interfaces, with slightly higher scores for CBCT views in LD mode. For 3D models, HD scored marginally higher in CI, whereas LD performed slightly better in VR. Observer agreement ranged from fair to excellent, and VR demonstrated reliability like CI. NASA-TLX results indicated reductions in mental and temporal demand, along with decreased effort and frustration during VR use, suggesting diminishing cognitive and emotional strain over time. In this pilot study, the findings suggest that LD CBCT may be feasible for selected CMF CASS applications and that VR offers an immersive and user-friendly alternative without compromising diagnostic reliability, supporting its potential role in future surgical planning.
- Open Access
- 18 August 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 49-58
Interactive AI annotation of medical images in a virtual reality environment
Purpose:: Artificial intelligence (AI) achieves high-quality annotations of radiological images, yet often lacks the robustness required in clinical practice. Interactive annotation starts with an AI-generated delineation, allowing radiologists to refine it with feedback, potentially improving precision and reliability. These techniques have been explored in two-dimensional desktop environments, but are not validated by radiologists or integrated with immersive visualization technologies. We used a Virtual Reality (VR) system to determine whether (1) the annotation quality improves when radiologists can edit the AI annotation and (2) whether the extra work done by editing is worthwhile. Methods:: We evaluated the clinical feasibility of an interactive VR approach to annotate mandibular and mental foramina on segmented 3D mandibular models. Three experienced dentomaxillofacial radiologists reviewed AI-generated annotations and, when needed, refined them at the voxel level in 3D space through click-based interactions until clinical standards were met. Results:: Our results indicate that integrating expert feedback within an immersive VR environment enhances annotation accuracy, improves clinical usability, and offers valuable insights for developing medical image analysis systems incorporating radiologist input. Conclusion:: This study is the first to compare the quality of original and interactive AI annotation and to use radiologists’ opinions as the measure. More research is needed for generalization.
- 18 August 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (1) , 49-58
Open AccessInteractive AI annotation of medical images in a virtual reality environment
Purpose:: Artificial intelligence (AI) achieves high-quality annotations of radiological images, yet often lacks the robustness required in clinical practice. Interactive annotation starts with an AI-generated delineation, allowing radiologists to refine it with feedback, potentially improving precision and reliability. These techniques have been explored in two-dimensional desktop environments, but are not validated by radiologists or integrated with immersive visualization technologies. We used a Virtual Reality (VR) system to determine whether (1) the annotation quality improves when radiologists can edit the AI annotation and (2) whether the extra work done by editing is worthwhile. Methods:: We evaluated the clinical feasibility of an interactive VR approach to annotate mandibular and mental foramina on segmented 3D mandibular models. Three experienced dentomaxillofacial radiologists reviewed AI-generated annotations and, when needed, refined them at the voxel level in 3D space through click-based interactions until clinical standards were met. Results:: Our results indicate that integrating expert feedback within an immersive VR environment enhances annotation accuracy, improves clinical usability, and offers valuable insights for developing medical image analysis systems incorporating radiologist input. Conclusion:: This study is the first to compare the quality of original and interactive AI annotation and to use radiologists’ opinions as the measure. More research is needed for generalization.
- Open Access
- 25 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1038
Towards the Emergence of the Medical Metaverse: A Pilot Study on Shared Virtual Reality for Orthognathic–Surgical Planning
Three-dimensional (3D) medical images are used for diagnosis and in surgical operation planning. Computer-assisted surgical simulations (CASS) are essential for complex surgical procedures that are often performed in an interdisciplinary manner. Traditionally, the participants study the designs on the same display. In 3D virtual reality (VR) environments, the planner is wearing a head-mounted display (HMD). The designs can be then examined in VR by other persons wearing HMDs, which is a practical use case for the medical metaverse. A multi-user VR environment was built for the planning of an orthognathic–surgical (correction of facial skeleton) operation. Four domain experts (oral and maxillofacial radiologists) experimented with the pilot system and found it useful. It enabled easier observation of the model and a better understanding of the structures. There was a voice connection and co-operation during the procedure was natural. The planning task is complex, leading to a certain level of complexity in the user interface.
- 25 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1038
Open AccessTowards the Emergence of the Medical Metaverse: A Pilot Study on Shared Virtual Reality for Orthognathic–Surgical Planning
Three-dimensional (3D) medical images are used for diagnosis and in surgical operation planning. Computer-assisted surgical simulations (CASS) are essential for complex surgical procedures that are often performed in an interdisciplinary manner. Traditionally, the participants study the designs on the same display. In 3D virtual reality (VR) environments, the planner is wearing a head-mounted display (HMD). The designs can be then examined in VR by other persons wearing HMDs, which is a practical use case for the medical metaverse. A multi-user VR environment was built for the planning of an orthognathic–surgical (correction of facial skeleton) operation. Four domain experts (oral and maxillofacial radiologists) experimented with the pilot system and found it useful. It enabled easier observation of the model and a better understanding of the structures. There was a voice connection and co-operation during the procedure was natural. The planning task is complex, leading to a certain level of complexity in the user interface.