Colette M. McKay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Colette M. McKay has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Katherine R. Henshall
Human Communication Research Centre, The University of Melbourne, Department of Otolaryngology, 384–388 Albert St., East Melbourne, Vic. 3002, Australia
3 shared publicationsHugh J. McDermott
Department of Otolaryngology, The University of Melbourne, 384-388 Albert Street, East Melbourne 3002, Australia
1 shared publicationRebecca J. Farrell
Department of Otolaryngology, The University of Melbourne, 384-388 Albert Street, East Melbourne 3002, Australia
1 shared publication
Latest Publications
- 20 June 2003
- Published by Elsevier in Hearing Research
- Vol. 181 (1-2) , 94-99
The perceptual effects of interphase gap duration in cochlear implant stimulation
- 20 June 2003
- Published by Elsevier in Hearing Research
- Vol. 181 (1-2) , 94-99
The perceptual effects of interphase gap duration in cochlear implant stimulation
- 20 March 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 113 (4) , 2054-2063
A practical method of predicting the loudness of complex electrical stimuli
The output of speech processors for multiple-electrode cochlear implants consists of current waveforms with complex temporal and spatial patterns. The majority of existing processors output sequential biphasic current pulses. This paper describes a practical method of calculating loudness estimates for such stimuli, in addition to the relative loudness contributions from different cochlear regions. The method can be used either to manipulate the loudness or levels in existing processing strategies, or to control intensity cues in novel sound processing strategies. The method is based on a loudness model described by McKay et al. [J. Acoust. Soc. Am. 110, 1514–1524 (2001)] with the addition of the simplifying approximation that current pulses falling within a temporal integration window of several milliseconds’ duration contribute independently to the overall loudness of the stimulus. Three experiments were carried out with six implantees who use the CI24M device manufactured by Cochlear Ltd. The first experiment validated the simplifying assumption, and allowed loudness growth functions to be calculated for use in the loudness prediction method. The following experiments confirmed the accuracy of the method using multiple-electrode stimuli with various patterns of electrode locations and current levels.
- 20 March 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 113 (4) , 2054-2063
A practical method of predicting the loudness of complex electrical stimuli
The output of speech processors for multiple-electrode cochlear implants consists of current waveforms with complex temporal and spatial patterns. The majority of existing processors output sequential biphasic current pulses. This paper describes a practical method of calculating loudness estimates for such stimuli, in addition to the relative loudness contributions from different cochlear regions. The method can be used either to manipulate the loudness or levels in existing processing strategies, or to control intensity cues in novel sound processing strategies. The method is based on a loudness model described by McKay et al. [J. Acoust. Soc. Am. 110, 1514–1524 (2001)] with the addition of the simplifying approximation that current pulses falling within a temporal integration window of several milliseconds’ duration contribute independently to the overall loudness of the stimulus. Three experiments were carried out with six implantees who use the CI24M device manufactured by Cochlear Ltd. The first experiment validated the simplifying assumption, and allowed loudness growth functions to be calculated for use in the loudness prediction method. The following experiments confirmed the accuracy of the method using multiple-electrode stimuli with various patterns of electrode locations and current levels.
- 1 February 2002
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 111 (2) , 1036-1044
Frequency-to-electrode allocation and speech perception with cochlear implants
The hypothesis was investigated that selectively increasing the discrimination of low-frequency information (below 2600 Hz) by altering the frequency-to-electrode allocation would improve speech perception by cochlear implantees. Two experimental conditions were compared, both utilizing ten electrode positions selected based on maximal discrimination. A fixed frequency range (200–10 513 Hz) was allocated either relatively evenly across the ten electrodes, or so that nine of the ten positions were allocated to the frequencies up to 2600 Hz. Two additional conditions utilizing all available electrode positions (15–18 electrodes) were assessed: one with each subject’s usual frequency-to-electrode allocation; and the other using the same analysis filters as the other experimental conditions. Seven users of the Nucleus CI22 implant wore processors mapped with each experimental condition for 2-week periods away from the laboratory, followed by assessment of perception of words in quiet and sentences in noise. Performance with both ten-electrode maps was significantly poorer than with both full-electrode maps on at least one measure. Performance with the map allocating nine out of ten electrodes to low frequencies was equivalent to that with the full-electrode maps for vowel perception and sentences in noise, but was worse for consonant perception. Performance with the evenly allocated ten-electrode map was equivalent to that with the full-electrode maps for consonant perception, but worse for vowel perception and sentences in noise. Comparison of the two full-electrode maps showed that subjects could fully adapt to frequency shifts up to ratio changes of 1.3, given 2 weeks’ experience. Future research is needed to investigate whether speech perception may be improved by the manipulation of frequency-to-electrode allocation in maps which have a full complement of electrodes in Nucleus implants.
- 1 February 2002
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 111 (2) , 1036-1044
Frequency-to-electrode allocation and speech perception with cochlear implants
The hypothesis was investigated that selectively increasing the discrimination of low-frequency information (below 2600 Hz) by altering the frequency-to-electrode allocation would improve speech perception by cochlear implantees. Two experimental conditions were compared, both utilizing ten electrode positions selected based on maximal discrimination. A fixed frequency range (200–10 513 Hz) was allocated either relatively evenly across the ten electrodes, or so that nine of the ten positions were allocated to the frequencies up to 2600 Hz. Two additional conditions utilizing all available electrode positions (15–18 electrodes) were assessed: one with each subject’s usual frequency-to-electrode allocation; and the other using the same analysis filters as the other experimental conditions. Seven users of the Nucleus CI22 implant wore processors mapped with each experimental condition for 2-week periods away from the laboratory, followed by assessment of perception of words in quiet and sentences in noise. Performance with both ten-electrode maps was significantly poorer than with both full-electrode maps on at least one measure. Performance with the map allocating nine out of ten electrodes to low frequencies was equivalent to that with the full-electrode maps for vowel perception and sentences in noise, but was worse for consonant perception. Performance with the evenly allocated ten-electrode map was equivalent to that with the full-electrode maps for consonant perception, but worse for vowel perception and sentences in noise. Comparison of the two full-electrode maps showed that subjects could fully adapt to frequency shifts up to ratio changes of 1.3, given 2 weeks’ experience. Future research is needed to investigate whether speech perception may be improved by the manipulation of frequency-to-electrode allocation in maps which have a full complement of electrodes in Nucleus implants.