ZCZidong Chen

Zidong Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zidong Chen has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Minbin Yu

    State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, Guangdong, China

    5 shared publications
  • Wenxin Yang

    Department of Glaucoma, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, Guangdong, China

    3 shared publications
  • Yangfan Yang

    State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China

    3 shared publications
  • Yanmei Fan

    Department of Glaucoma, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, Guangdong, China

    3 shared publications
  • Yuning Zhang

    Department of Glaucoma, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, Guangdong, China

    3 shared publications
  • Pingping Liu

    Department of Glaucoma, Sun Yat-Sen University Zhongshan Ophthalmic Center, Guangzhou, Guangdong, China

    2 shared publications

Latest Publications

  • Dose-Effectiveness Optimizing in Micropulse Transscleral Cyclophotocoagulation

    by Yanyan Wu, Xiaofeng Zhu, Zidong Chen, Ziyi Cai, Pingping Liu, Yimin Zhong, Xinbo Gao, Yingting Zhu, Zhidong Li, Shu Tu, et al.

  • Comparison of baseline clinical characteristics and patterns of visual field defects between high-tension and normal-tension glaucoma

    by Zidong Chen, Wenxin Yang, Yangfan Yang, Yuzhen Jiang, Yuning Zhang, Xinyi Zhang, Chongxuan Luo, Mingqin Wang, Yanmei Fan, Pingping Liu, et al.

    Aims To compare the baseline clinical characteristics and patterns of visual field defects between high-tension glaucoma (HTG) and normal-tension glaucoma (NTG) in the Laser in Glaucoma and Ocular Hypertension (LiGHT) China subjects. Methods All patients (n=622) were recruited at Zhongshan Ophthalmic Center from 2015 to 2019. 1105 open-angle glaucoma eyes of 622 patients were classified as NTG (n=559) and HTG eyes (n=546) according to the baseline intraocular pressure (IOP) of 21 mm Hg. The mean deviation (MD), regional MD of the Glaucoma Hemifield Test regions and regional difference values were calculated. Daytime phasing IOP was recorded at 8:00, 10:00, 11:30, 14:30 and 17:00 hour. Multiple regression analyses were conducted for each regional difference. Results Patients with NTG were older, more likely to be female, hypertensive and suffer ischaemic heart disease than patients with HTG (pConclusions In the LiGHT China trial, NTG and HTG showed similar visual field defects severity at enrolment. However, NTG showed more severe hemifield asymmetry compared with HTG, and higher short-time IOP fluctuations might exacerbate this asymmetry in NTG.


  • Open Access

    Development and Validation of an Internet-Based Remote Perimeter (Perimouse)

    by Zidong Chen, Xiaoyuan Shen, Yuning Zhang, Wenxin Yang, Jiexin Ye, Zhiqiang Ouyang, Guifeng Zheng, Yangfan Yang, Minbin Yu

    Purpose: We sought to validate the feasibility of Perimouse, an internet-based remote perimeter that allows for natural fixation and can be performed on most computers via a web page. Methods: In this cross-sectional study, Perimouse evaluated the visual field of 45 healthy people and 27 patients with primary open-angle glaucoma on a laptop. Participants used a mouse cursor to locate new dots on the screen that were determined by preset saccade vectors. A “click and confirm” strategy was used to eliminate the unwanted visual search. Dot brightness was either fixed at 12 dB in the suprathreshold program (screening program) or variable in the threshold program. We compared Perimouse outcomes with the Humphrey Field Analyzer (HFA) 24-2 Swedish Interactive Testing Algorithm standard program. Results: In the screening program, Perimouse showed moderate to high concordance with HFA. The intraclass coefficient ranged from 0.58 to 0.86 in different areas of Garway–Heath mapping. In the threshold program, normal subjects had threshold ranging from 19 to 16 dB, presenting sensitivity changes according to the “hill of vision”. The test–retest difference was 0.09 dB. Habitual spectacle correction and environmental luminance (2–337 lux) had little impact on the central or peripheral threshold (P > 0.05). The correlation between Perimouse and HFA threshold sensitivity was strong (R = 0.950), although Perimouse mean defect was 4.40 dB higher than the HFA mean defect. Conclusions: Perimouse is a reliable visual field test that correlates strongly with HFA. It shows potential for population screening and monitoring visual field defects. Translational Relevance: Perimouse assesses the visual field using saccade vectors without eye trackers, enhancing its accessibility via a web page.


  • Continuous 24-hour intraocular pressure monitoring in normal Chinese adults using a novel contact lens sensor system

    by Yuning Zhang, Yifan Wei, Ching Hymn Christopher Lee, Ping Wai Or, Isuru Kaweendra Karunaratne, Mingjie Deng, Wenxin Yang, Iok Tong Chong, Yangfan Yang, Zidong Chen, et al.

    Aims To investigate the physiological nyctohemeral intraocular pressure (IOP) rhythms of normal Chinese adults using a novel contact lens sensor system (CLS) that can output IOP in millimetres of mercury (mm Hg) continuously. Methods Fifty-nine eyes of 59 normal Chinese adults completed 24-hour IOP monitoring using the novel CLS. A descriptive analysis was conducted on the 24-hour IOP mean, peak and acrophase, trough and bathyphase, fluctuation, and mean amplitude of intraocular pressure excursion (MAPE). The continuous data were analysed at several periods (diurnal period, 08:00–20:00 hours; nocturnal period, 22:00–06:00 hours; sleep time, 0:00–06:00 hours), and compared between right and left eyes, males and females, and different age ranges (Results Normal adults had a lower peak, higher trough, smaller fluctuation and smaller MAPE (p0.1 for all comparisons). The male group had larger 24-hour and diurnal IOP fluctuation and MAPE (pConclusion Continuous 24-hour IOP output from the CLS in normal Chinese was stable with a comparable mean level between day and night, as well as scattered acrophase and bathyphase. The 24-hour IOP mean increased with age, and IOP variations were positively correlated to age and male sex.


  • Open Access

    Early impairment of magnocellular visual pathways mediated by isolated-check visual evoked potentials in primary open-angle glaucoma: a cross-sectional study

    by Qiaona Ye, Kezheng Xu, Zidong Chen, Zitian Liu, Yanmei Fan, Pingping Liu, Minbin Yu, Yangfan Yang

    Objective To explore different performances in the magnocellular (MC) and parvocellular (PC) visual pathways in patients with primary open-angle glaucoma (POAG) and to objectively assess impairment in early stage of POAG. Methods and analysis This is a cross-sectional study. MC and PC visual pathways were assessed using isolated-check visual evoked potential (ic-VEP). Visual acuity, intraocular pressure, fundus examination, optical coherence tomography and visual field were measured. Signal-to-noise ratios (SNRs), mediated by ic-VEP were recorded. The Spearman’s correlation analysis was used to estimate the relationships between visual functions and structures. Receiver-operating-characteristic (ROC) curves were used to estimate the accuracy in detection of early POAG. Results 60 participants (30 early POAG eyes and 30 age-matched control subjects) were recruited. MC visual pathway showed a non-linear response function, while PC visual pathway was a linear response function as contrast increased. Early POAG eyes exhibited significantly weaker initial contrast gains and lower maximum responses in the MC visual pathway (p=0.001, p=0.004, respectively). The SNRs at 8% and 32% depths of modulation (DOM) were significantly correlated with temporal-side retinal nerve fibre layer (RNFL) thickness in early POAG in MC-biased stimulation (p=0.017, p=0.020, respectively). The areas under ROC of 16% DOM were 0.780 (sensitivity 80.0%, specificity 63.3%) with the cut-off SNR of 2.07. Conclusions The MC visual pathway was damaged in the early stage of POAG. The SNRs at 8% and 32% DOM of MC-biased stimulation were significantly correlated with temporal-side RNFL thickness in early POAG, which helped in understanding the mechanisms of visual impairment in the early stage of POAG.


  • Open Access

    Motion-generated optical information allows event perception despite blurry vision in AMD and amblyopic patients

    by Jing Samantha Pan, Jingrong Li, Zidong Chen, Emily A. Mangiaracina, Christopher S. Connell, Hongyuan Wu, Xiaoye Michael Wang, Geoffrey P. Bingham, Shirin E. Hassan

    Events consist of objects in motion. When objects move, their opaque surfaces reflect light and produce both static image structure and dynamic optic flow. The static and dynamic optical information co-specify events. Patients with age-related macular degeneration (AMD) and amblyopia cannot identify static objects because of weakened image structure. However, optic flow is detectable despite blurry vision because visual motion measurement uses low spatial frequencies. When motion ceases, image structure persists and might preserve properties specified by optic flow. We tested whether optic flow and image structure interact to allow event perception with poor static vision. AMD (Experiment 1), amblyopic (Experiments 2 and 3), and normally sighted observers identified common events from either blurry (Experiments 1 and 2) or clear images (Experiment 3), when either single image frames were presented, a sequence of frames was presented with motion masks, or a sequence of frames was presented with detectable motion. Results showed that with static images, but no motion, events were not perceived well by participants other than controls in Experiment 3. However, with detectable motion, events were perceived. Immediately following this and again after five days, participants were able to identify events from the original static images. So, when image structure information is weak, optic flow compensates for it and enables event perception. Furthermore, weakened static image structure information nevertheless preserves information that was once available in optic flow. The combination is powerful and allows events to be perceived accurately and stably despite blurry vision.