Mia Buljan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mia Buljan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ana Zulijani
Department of Dental Medicine, Faculty of Dental Medicine and Health of Osijek, Josip Juraj Strossmayer University of Osijek, Crkvena 21, 31000 Osijek, Croatia
2 shared publications - Berislav Perić
School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
2 shared publications - Martina Slaj
School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
2 shared publications - Valentina Petrović
Private Dental Practice, 10000 Zagreb, Croatia
2 shared publications - Luka Morelato
Private Dental Practice, 52440 Poreč, Croatia
1 shared publication - Tadej Čivljak
Department of Oral Surgery, Dental Polyclinic Zagreb, 10000 Zagreb, Croatia
1 shared publication
Latest Publications
- Open Access
- 24 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (9) , 3572
A Comparison of Dental Arch Width and Length on 3D Digital and Plaster Models
The aim of the study was to determine potential deviation in measurements of commonly used orthodontic variables, including intermolar width (IMW), intercanine width (ICW), and arch perimeter (AP), when measured on three-dimensional images compared to measurements performed on plaster models obtained from alginate impressions using a hand-held digital vernier caliper. A total of 120 sets of models were divided into four groups: plaster models made from an alginate impression, digitized plaster models made from an alginate and silicone impression, and digital models obtained via intraoral scan. The repeated measurements analysis of variance (ANOVA) with Sidak post-hoc test was applied to test differences in measurements between the four methods. The results show better agreement for intermolar and intercanine width (r = 0.468–0.967) and smaller measurement error (ME = 0.53–1.07) compared to arch length (r = 0.422–0.477; ME = 2.04–2.89). Better agreement levels were more frequently observed between plaster models with intraoral scans than between digitized plaster models. The deviations in intermolar and intercanine width measurements between the hand-held digital vernier caliper and digital analyses were found to be clinically insignificant. The observed difference in arch perimeter suggests that curved measurements may not be clinically acceptable.
- 24 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (9) , 3572
Open AccessA Comparison of Dental Arch Width and Length on 3D Digital and Plaster Models
The aim of the study was to determine potential deviation in measurements of commonly used orthodontic variables, including intermolar width (IMW), intercanine width (ICW), and arch perimeter (AP), when measured on three-dimensional images compared to measurements performed on plaster models obtained from alginate impressions using a hand-held digital vernier caliper. A total of 120 sets of models were divided into four groups: plaster models made from an alginate impression, digitized plaster models made from an alginate and silicone impression, and digital models obtained via intraoral scan. The repeated measurements analysis of variance (ANOVA) with Sidak post-hoc test was applied to test differences in measurements between the four methods. The results show better agreement for intermolar and intercanine width (r = 0.468–0.967) and smaller measurement error (ME = 0.53–1.07) compared to arch length (r = 0.422–0.477; ME = 2.04–2.89). Better agreement levels were more frequently observed between plaster models with intraoral scans than between digitized plaster models. The deviations in intermolar and intercanine width measurements between the hand-held digital vernier caliper and digital analyses were found to be clinically insignificant. The observed difference in arch perimeter suggests that curved measurements may not be clinically acceptable.
- Open Access
- 26 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 730
Comparison of Tooth Size Measurements in Orthodontics Using Conventional and 3D Digital Study Models
(1) Background: The objective of this study was to assess which digitization method produces the biggest deviation in the 3D images of tooth size from plaster models made using alginate impressions, which are considered the gold standard in orthodontics. (2) Methods: The sample used in this study included 30 subjects (10 males and 20 females). Measurements were made on four types of models: (1) digital models obtained through intraoral scanning and digitized models of plaster cast made from (2) alginate impressions, (3) silicone impressions, and (4) conventional plaster models. Mesio-distal (MD) and buccal/labial–lingual/palatal (BL) dimensions were measured on the reference teeth of the right side of the jaw (central incisor, canine, first premolar, and first molar). Comparisons of tooth size between the methods were conducted using a repeated measurement analysis of variance and the Friedman test, while the intraclass correlation coefficient was used to determine agreement between the different methods. (3) Results: The results showed a similar level of agreement between the conventional and digital models in both jaws and the anterior, middle, and posterior segments. Better agreement was found for the MD measurements (r = 0.337–0.798; p ≤ 0.05) compared to the BL measurements (r = 0.016–0.542), with a smaller mean difference for MD (0.001–0.50 mm) compared to BL (0.02–1.48 mm) and a smaller measurement error for MD (0.20–0.39) compared to BL (0.38–0.89). There was more frequently a better level of agreement between 3D images than measurements made using a digital caliper on the plaster models with 3D images. (4) Conclusions: The differences in measurements between the digital models and conventional plaster models were small and clinically acceptable.
- 26 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 730
Open AccessComparison of Tooth Size Measurements in Orthodontics Using Conventional and 3D Digital Study Models
(1) Background: The objective of this study was to assess which digitization method produces the biggest deviation in the 3D images of tooth size from plaster models made using alginate impressions, which are considered the gold standard in orthodontics. (2) Methods: The sample used in this study included 30 subjects (10 males and 20 females). Measurements were made on four types of models: (1) digital models obtained through intraoral scanning and digitized models of plaster cast made from (2) alginate impressions, (3) silicone impressions, and (4) conventional plaster models. Mesio-distal (MD) and buccal/labial–lingual/palatal (BL) dimensions were measured on the reference teeth of the right side of the jaw (central incisor, canine, first premolar, and first molar). Comparisons of tooth size between the methods were conducted using a repeated measurement analysis of variance and the Friedman test, while the intraclass correlation coefficient was used to determine agreement between the different methods. (3) Results: The results showed a similar level of agreement between the conventional and digital models in both jaws and the anterior, middle, and posterior segments. Better agreement was found for the MD measurements (r = 0.337–0.798; p ≤ 0.05) compared to the BL measurements (r = 0.016–0.542), with a smaller mean difference for MD (0.001–0.50 mm) compared to BL (0.02–1.48 mm) and a smaller measurement error for MD (0.20–0.39) compared to BL (0.38–0.89). There was more frequently a better level of agreement between 3D images than measurements made using a digital caliper on the plaster models with 3D images. (4) Conclusions: The differences in measurements between the digital models and conventional plaster models were small and clinically acceptable.