Ge Lei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ge Lei has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Cunyang Que
2 shared publicationsDi Yin
2 shared publications- Gang Li
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, People’s Republic of China
2 shared publications - Jinliu Su
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
2 shared publications Junhui Yue
2 shared publications- Yudong Liu
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 shared publications
Latest Publications
- 13 October 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
The CEPC clock issue and fine-tuning of the circumference
The CEPC clock issue is related with the RF frequency coordination between the various accelerator systems and may affect the operation modes of both the accelerator and the detector. The timing structure of CEPC has been restudied with the collaboration of the accelerator team and the detector team. After discussions between two sides, the CEPC bunch structure is set such that the spacings between adjacent bunches in any CEPC operation mode are integer numbers of 23.08[Formula: see text]ns. The master CEPC clock will be provided by the accelerator to the detector systems with a frequency of 43.33[Formula: see text]MHz, synchronous to the beam. The CEPC detector system relies on the clock to sample physics signal at the right time. It was found that if the circumference of CEPC is slightly changed to 99955.42[Formula: see text]m, the detector would benefit more for the first 10-year operation.
- 13 October 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
The CEPC clock issue and fine-tuning of the circumference
The CEPC clock issue is related with the RF frequency coordination between the various accelerator systems and may affect the operation modes of both the accelerator and the detector. The timing structure of CEPC has been restudied with the collaboration of the accelerator team and the detector team. After discussions between two sides, the CEPC bunch structure is set such that the spacings between adjacent bunches in any CEPC operation mode are integer numbers of 23.08[Formula: see text]ns. The master CEPC clock will be provided by the accelerator to the detector systems with a frequency of 43.33[Formula: see text]MHz, synchronous to the beam. The CEPC detector system relies on the clock to sample physics signal at the right time. It was found that if the circumference of CEPC is slightly changed to 99955.42[Formula: see text]m, the detector would benefit more for the first 10-year operation.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Experimental investigation on coupled-bunch instability and suppression for the upgrade of Beijing Electron–Positron Collider (BEPCII)
After touching the design collision luminosity of 1.0 × 1033 cm−2 s−1 in 2016, this target has not been reached again for the upgrade of Beijing Electron–Positron Collider during physical collision operation in subsequent years due to various factors, such as the collision background, noise, and equipment stability under high power operation. One of the most serious factors was the beam instability, especially the coupled-bunch instability, whose sideband distribution was clearly displayed on the spectrum analyzer when the feedback system was OFF. Experimental measurements on coupled-bunch instability and the damping from the feedback system were carried out over the past two years. These measurements were conducted by transiently turning off/on the feedback system, and the bunch-by-bunch oscillations were recorded to obtain the mode distribution and growth and damping rates. The experimental results demonstrate that the feedback damping is strong enough to suppress instability, and precise adjustments to the feedback system during physical collision operation can increase the collision luminosity, which has been verified in last year’s physical run.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Experimental investigation on coupled-bunch instability and suppression for the upgrade of Beijing Electron–Positron Collider (BEPCII)
After touching the design collision luminosity of 1.0 × 1033 cm−2 s−1 in 2016, this target has not been reached again for the upgrade of Beijing Electron–Positron Collider during physical collision operation in subsequent years due to various factors, such as the collision background, noise, and equipment stability under high power operation. One of the most serious factors was the beam instability, especially the coupled-bunch instability, whose sideband distribution was clearly displayed on the spectrum analyzer when the feedback system was OFF. Experimental measurements on coupled-bunch instability and the damping from the feedback system were carried out over the past two years. These measurements were conducted by transiently turning off/on the feedback system, and the bunch-by-bunch oscillations were recorded to obtain the mode distribution and growth and damping rates. The experimental results demonstrate that the feedback damping is strong enough to suppress instability, and precise adjustments to the feedback system during physical collision operation can increase the collision luminosity, which has been verified in last year’s physical run.
- 1 January 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (01) , P01026
The advanced motion control system in HEPS beamline
In synchrotron radiation facilities such as the High Energy Photon Source (HEPS), numerous motorized actuators are equipped on the optics devices of HEPS beamline to manipulate the orientation of crystals and mirrors, thereby altering the position and characteristics of X-rays. The motion control system (MCS) plays an important role in the optics devices of HEPS beamlines, such as monochromator, K-B mirror and sample plants. In order to acquire the specify properties of X-ray and satisfy the complex experimental requirements, MCS must have the ability to handle the complicated control demands. Therefore, HEPS has developed a standardized motion control system for synchrotron radiation applications, which is a distributed system based on EtherCAT fieldbus. The hardware of this system consists of the control unit and driver unit, which has the flexibility to suit for different applications. The software of MCS is designed under the Experimental Physics and Industrial Control System (EPICS), which is very popular in synchrotron radiation facilities all over the world. In this paper, the performance tests of IOC software were demonstrated, and a few flyscan applications were given, which include spiral scan, raster scan and position event trigger, to demonstrate the feasibility and effectiveness of this system.
- 1 January 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (01) , P01026
The advanced motion control system in HEPS beamline
In synchrotron radiation facilities such as the High Energy Photon Source (HEPS), numerous motorized actuators are equipped on the optics devices of HEPS beamline to manipulate the orientation of crystals and mirrors, thereby altering the position and characteristics of X-rays. The motion control system (MCS) plays an important role in the optics devices of HEPS beamlines, such as monochromator, K-B mirror and sample plants. In order to acquire the specify properties of X-ray and satisfy the complex experimental requirements, MCS must have the ability to handle the complicated control demands. Therefore, HEPS has developed a standardized motion control system for synchrotron radiation applications, which is a distributed system based on EtherCAT fieldbus. The hardware of this system consists of the control unit and driver unit, which has the flexibility to suit for different applications. The software of MCS is designed under the Experimental Physics and Industrial Control System (EPICS), which is very popular in synchrotron radiation facilities all over the world. In this paper, the performance tests of IOC software were demonstrated, and a few flyscan applications were given, which include spiral scan, raster scan and position event trigger, to demonstrate the feasibility and effectiveness of this system.
- 3 June 2021
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 5 (3) , 404-408
Upgrade design and prototype implementation of cryogenic control system in BEPCII
- 3 June 2021
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 5 (3) , 404-408
Upgrade design and prototype implementation of cryogenic control system in BEPCII