Satish Saluja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Satish Saluja has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Arun Soni
Department of Neonatology, Institute of Child Health, Sir Ganga Ram Hospital, New Delhi, India
4 shared publications- Harpreet Singh
Child Health Imprints (CHIL) Pte. Ltd, Singapore, Singapore
3 shared publications Manoj Modi
Department of Neonatology, Institute of Child Health, Sir Ganga Ram Hospital, New Delhi, India
3 shared publications- Ryan Michael Mcadams
Department of Pediatrics, University of Wisconsin School of Medicine and Public Health, Madison, USA
3 shared publications - Su Jin Cho
Department of Pediatrics, Ewha Womans University College of Medicine, Seoul, Republic of Korea
3 shared publications Anup Thakur
Department of Neonatology, Institute of Child Health, Sir Ganga Ram Hospital, New Delhi, India
2 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (11) , 1457
Edge-Hosted LLM-Assisted NICU Discharge Summary Generation: Field-Level Evaluation Using a Clinician-Defined Rubric
Objective: To develop and evaluate an edge-hosted Large Language Model (LLM)-assisted system for automated Neonatal Intensive Care Unit (NICU) discharge summary generation using an evidence-grounded, field-level evaluation framework. Methods: This implementation and evaluation study was conducted in a Level III NICU in India. Longitudinal patient records were constructed from integrated bedside physiologic data (ARCHITECT) and a structured electronic medical record (EMR) platform Although an embedded audio–video module was present, it was not used in this study. Automated discharge summaries were generated by MORPHEUS, an edge-hosted orchestration pipeline running on NVIDIA Jetson AGX Orin hardware with JetPack 6.2. Local orchestration, preprocessing, and workflow execution were performed on the edge device, while language generation inference was performed using the OpenAI gpt-4o-mini API. Documentation quality was assessed with an LLM-based evaluator guided by a clinician-defined rubric comprising 72 fields organized across 14 section contexts and scored on five dimensions: clinical accuracy, completeness, actionability, coherence, and non-hallucination. Paired, field-level comparisons were performed against clinician-authored summaries. Of 549 NICU admissions screened between 1 October 2024 and 3 November 2025, 401 met the inclusion criteria for evaluation. Prompt refinement was performed iteratively using omission-derived feedback without model weight updates. Results: Across 401 evaluated admissions, MORPHEUS-generated summaries demonstrated higher rubric-based scores and lower omission burden than clinician-authored summaries within the structured evaluation framework used in this study, with mean scores of 0.93 versus 0.75 for accuracy, 0.91 versus 0.67 for completeness, 0.93 versus 0.72 for actionability, 0.94 versus 0.74 for coherence, and 0.95 versus 0.78 for non-hallucination, with the largest absolute advantage observed for completeness. Error taxonomy analysis demonstrated fewer omissions, unsupported assertions, and contradictions in AI-generated summaries than in clinician-authored summaries. Iterative prompt refinement was associated with directional improvement across quality dimensions and reduced omission burden, with omission rate per patient decreasing from 2.484 to 1.807 in the later iteration. Conclusions: An edge-hosted LLM-assisted pipeline can generate NICU discharge summaries that meet or exceed clinician-authored documentation quality under a reproducible, clinician-grounded evaluation framework. These findings support the feasibility of deploying edge-orchestrated generative AI systems for high-stakes neonatal clinical documentation using a clinician-grounded field-level evaluation framework.
- 25 May 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (11) , 1457
Open AccessEdge-Hosted LLM-Assisted NICU Discharge Summary Generation: Field-Level Evaluation Using a Clinician-Defined Rubric
Objective: To develop and evaluate an edge-hosted Large Language Model (LLM)-assisted system for automated Neonatal Intensive Care Unit (NICU) discharge summary generation using an evidence-grounded, field-level evaluation framework. Methods: This implementation and evaluation study was conducted in a Level III NICU in India. Longitudinal patient records were constructed from integrated bedside physiologic data (ARCHITECT) and a structured electronic medical record (EMR) platform Although an embedded audio–video module was present, it was not used in this study. Automated discharge summaries were generated by MORPHEUS, an edge-hosted orchestration pipeline running on NVIDIA Jetson AGX Orin hardware with JetPack 6.2. Local orchestration, preprocessing, and workflow execution were performed on the edge device, while language generation inference was performed using the OpenAI gpt-4o-mini API. Documentation quality was assessed with an LLM-based evaluator guided by a clinician-defined rubric comprising 72 fields organized across 14 section contexts and scored on five dimensions: clinical accuracy, completeness, actionability, coherence, and non-hallucination. Paired, field-level comparisons were performed against clinician-authored summaries. Of 549 NICU admissions screened between 1 October 2024 and 3 November 2025, 401 met the inclusion criteria for evaluation. Prompt refinement was performed iteratively using omission-derived feedback without model weight updates. Results: Across 401 evaluated admissions, MORPHEUS-generated summaries demonstrated higher rubric-based scores and lower omission burden than clinician-authored summaries within the structured evaluation framework used in this study, with mean scores of 0.93 versus 0.75 for accuracy, 0.91 versus 0.67 for completeness, 0.93 versus 0.72 for actionability, 0.94 versus 0.74 for coherence, and 0.95 versus 0.78 for non-hallucination, with the largest absolute advantage observed for completeness. Error taxonomy analysis demonstrated fewer omissions, unsupported assertions, and contradictions in AI-generated summaries than in clinician-authored summaries. Iterative prompt refinement was associated with directional improvement across quality dimensions and reduced omission burden, with omission rate per patient decreasing from 2.484 to 1.807 in the later iteration. Conclusions: An edge-hosted LLM-assisted pipeline can generate NICU discharge summaries that meet or exceed clinician-authored documentation quality under a reproducible, clinician-grounded evaluation framework. These findings support the feasibility of deploying edge-orchestrated generative AI systems for high-stakes neonatal clinical documentation using a clinician-grounded field-level evaluation framework.
- Open Access
- 10 February 2025
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 184 (2) , 1
Correction to: Echocardiographic characteristics in neonates with septic shock
- 10 February 2025
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 184 (2) , 1
Open AccessCorrection to: Echocardiographic characteristics in neonates with septic shock
- 26 January 2024
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 183 (4) , 1849-1855
Echocardiographic characteristics in neonates with septic shock
Clinical parameters used for hemodynamic assessment and titration of vasopressor therapy in neonates with septic shock have several limitations. Functional echocardiography is an emerging tool for bedside assessment of cardiac function and may be useful for diagnosis of shock and assessing the response to therapy. Data regarding echocardiographic parameters in neonates with shock is lacking. This prospective observational study was conducted in a Level III NICU with the primary objective of comparing echocardiographic characteristics of neonates with septic shock at diagnosis, following fluid boluses, and after maximum inotropic support [A1]. Additionally, we compared these characteristics with those of healthy stable neonates who were gestation and postnatal age-matched. A total of 36 neonates with septic shock and 30 gestation and postnatal age-matched controls were enrolled. The mean (SD) gestation and birth weight of neonates with septic shock were 30.6 (4.0) weeks and 1538 (728) g, respectively. Gram-negative bacilli constituted 78.9% of all isolates. At presentation, there was no significant difference between neonates with shock and controls in terms of ventricular outputs, shortening fraction, ratio of early to late diastolic trans-mitral flow velocity, and myocardial performance indices. The distensibility index of inferior vena cava was higher in neonates with shock compared to controls, (17% vs 10%, (p < 0.01)). Left ventricular output was 209 (92) and 227 (102) ml/kg/min (p = 0.53) and right ventricular output was 427 (203) and 459 (227) ml/kg/min, (p = 0.03), respectively, before and after inotropic therapy. Conclusion: Echocardiographic parameters may not differentiate neonates with septic shock from hemodynamically stable neonates. Neonates with shock associated with predominantly gram-negative sepsis are not able to augment cardiac functions, either at the onset or after administration of inotropes. Trial registration: (CTRI/2017/12/010766). What is known: • For neonates with shock, echocardiography is becoming increasingly popular as an objective method of evaluating hemodynamics. • In healthy preterm neonate, cardiac output has been known to increase in response to altered hemodynamics during states of increased oxygen demand. What is new: • In the setting of septic shock induced by gram-negative organisms, echocardiographic parameters are less likely to assist in the assessment of the response to vasoactive agents. Cytokines, induced by gram-negative organisms, may alter adrenoreceptors in myocardium and vasculature.
- 26 January 2024
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 183 (4) , 1849-1855
Echocardiographic characteristics in neonates with septic shock
Clinical parameters used for hemodynamic assessment and titration of vasopressor therapy in neonates with septic shock have several limitations. Functional echocardiography is an emerging tool for bedside assessment of cardiac function and may be useful for diagnosis of shock and assessing the response to therapy. Data regarding echocardiographic parameters in neonates with shock is lacking. This prospective observational study was conducted in a Level III NICU with the primary objective of comparing echocardiographic characteristics of neonates with septic shock at diagnosis, following fluid boluses, and after maximum inotropic support [A1]. Additionally, we compared these characteristics with those of healthy stable neonates who were gestation and postnatal age-matched. A total of 36 neonates with septic shock and 30 gestation and postnatal age-matched controls were enrolled. The mean (SD) gestation and birth weight of neonates with septic shock were 30.6 (4.0) weeks and 1538 (728) g, respectively. Gram-negative bacilli constituted 78.9% of all isolates. At presentation, there was no significant difference between neonates with shock and controls in terms of ventricular outputs, shortening fraction, ratio of early to late diastolic trans-mitral flow velocity, and myocardial performance indices. The distensibility index of inferior vena cava was higher in neonates with shock compared to controls, (17% vs 10%, (p < 0.01)). Left ventricular output was 209 (92) and 227 (102) ml/kg/min (p = 0.53) and right ventricular output was 427 (203) and 459 (227) ml/kg/min, (p = 0.03), respectively, before and after inotropic therapy. Conclusion: Echocardiographic parameters may not differentiate neonates with septic shock from hemodynamically stable neonates. Neonates with shock associated with predominantly gram-negative sepsis are not able to augment cardiac functions, either at the onset or after administration of inotropes. Trial registration: (CTRI/2017/12/010766). What is known: • For neonates with shock, echocardiography is becoming increasingly popular as an objective method of evaluating hemodynamics. • In healthy preterm neonate, cardiac output has been known to increase in response to altered hemodynamics during states of increased oxygen demand. What is new: • In the setting of septic shock induced by gram-negative organisms, echocardiographic parameters are less likely to assist in the assessment of the response to vasoactive agents. Cytokines, induced by gram-negative organisms, may alter adrenoreceptors in myocardium and vasculature.
- Open Access
- 8 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 142433-142446
An Ontology and Rule-Based Clinical Decision Support System for Personalized Nutrition Recommendations in the Neonatal Intensive Care Unit
Premature neonates hospitalized in the neonatal intensive care unit (NICU) have high nutritional needs to ensure optimal growth and development. Monitoring adherence to neonatal nutritional guidelines and providing personalized nutritional recommendations are essential for promoting their health. However, ensuring consistent adherence to these guidelines is challenging. To address this, we developed a clinical decision support system using an ontology and rule-based approach to offer personalized nutrition recommendations for preterm infants in the NICU. The Nutrition Recommendation Ontology (NRO) was developed, incorporating 121 classes, 366 axioms, and 157 semantic rules based on standard nutrition guidelines and retrospective data from 601 NICU patients, using a cumulative 8460 patient-days data collected from a single center between 2019-2021. While the ontology represented the conceptual knowledge, the rules encoded the procedural knowledge. The integrated NRO-based system serves as a reasoning engine, enabling the generation of patient-specific feeding recommendations and assisting in identifying deviations from established guidelines. To validate its efficacy, the NRO system was tested on 10 sample case studies and achieved 98% accuracy, as assessed by a panel of neonatologists. Our findings indicate that the NRO-based clinical decision support system can provide accurate personalized nutrition recommendations and assess guideline adherence in the NICU. With further real-world validation, we anticipate that this approach could significantly improve nutrition delivery, prevent malnutrition, and ultimately improve outcomes for preterm infants.
- 8 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 142433-142446
Open AccessAn Ontology and Rule-Based Clinical Decision Support System for Personalized Nutrition Recommendations in the Neonatal Intensive Care Unit
Premature neonates hospitalized in the neonatal intensive care unit (NICU) have high nutritional needs to ensure optimal growth and development. Monitoring adherence to neonatal nutritional guidelines and providing personalized nutritional recommendations are essential for promoting their health. However, ensuring consistent adherence to these guidelines is challenging. To address this, we developed a clinical decision support system using an ontology and rule-based approach to offer personalized nutrition recommendations for preterm infants in the NICU. The Nutrition Recommendation Ontology (NRO) was developed, incorporating 121 classes, 366 axioms, and 157 semantic rules based on standard nutrition guidelines and retrospective data from 601 NICU patients, using a cumulative 8460 patient-days data collected from a single center between 2019-2021. While the ontology represented the conceptual knowledge, the rules encoded the procedural knowledge. The integrated NRO-based system serves as a reasoning engine, enabling the generation of patient-specific feeding recommendations and assisting in identifying deviations from established guidelines. To validate its efficacy, the NRO system was tested on 10 sample case studies and achieved 98% accuracy, as assessed by a panel of neonatologists. Our findings indicate that the NRO-based clinical decision support system can provide accurate personalized nutrition recommendations and assess guideline adherence in the NICU. With further real-world validation, we anticipate that this approach could significantly improve nutrition delivery, prevent malnutrition, and ultimately improve outcomes for preterm infants.
- Open Access
Machine Learning-Based Automatic Classification of Video Recorded Neonatal Manipulations and Associated Physiological Parameters: A Feasibility Study
Our objective in this study was to determine if machine learning (ML) can automatically recognize neonatal manipulations, along with associated changes in physiological parameters. A retrospective observational study was carried out in two Neonatal Intensive Care Units (NICUs) between December 2019 to April 2020. Both the video and physiological data (heart rate (HR) and oxygen saturation (SpO2)) were captured during NICU hospitalization. The proposed classification of neonatal manipulations was achieved by a deep learning system consisting of an Inception-v3 convolutional neural network (CNN), followed by transfer learning layers of Long Short-Term Memory (LSTM). Physiological signals prior to manipulations (baseline) were compared to during and after manipulations. The validation of the system was done using the leave-one-out strategy with input of 8 s of video exhibiting manipulation activity. Ten neonates were video recorded during an average length of stay of 24.5 days. Each neonate had an average of 528 manipulations during their NICU hospitalization, with the average duration of performing these manipulations varying from 28.9 s for patting, 45.5 s for a diaper change, and 108.9 s for tube feeding. The accuracy of the system was 95% for training and 85% for the validation dataset. In neonates 2, and, for neonates ≥32 weeks’ gestation, patting and tube feeding were associated with significant changes in HR. The presented system can classify and document the manipulations with high accuracy. Moreover, the study suggests that manipulations impact physiological parameters.
Open AccessMachine Learning-Based Automatic Classification of Video Recorded Neonatal Manipulations and Associated Physiological Parameters: A Feasibility Study
Our objective in this study was to determine if machine learning (ML) can automatically recognize neonatal manipulations, along with associated changes in physiological parameters. A retrospective observational study was carried out in two Neonatal Intensive Care Units (NICUs) between December 2019 to April 2020. Both the video and physiological data (heart rate (HR) and oxygen saturation (SpO2)) were captured during NICU hospitalization. The proposed classification of neonatal manipulations was achieved by a deep learning system consisting of an Inception-v3 convolutional neural network (CNN), followed by transfer learning layers of Long Short-Term Memory (LSTM). Physiological signals prior to manipulations (baseline) were compared to during and after manipulations. The validation of the system was done using the leave-one-out strategy with input of 8 s of video exhibiting manipulation activity. Ten neonates were video recorded during an average length of stay of 24.5 days. Each neonate had an average of 528 manipulations during their NICU hospitalization, with the average duration of performing these manipulations varying from 28.9 s for patting, 45.5 s for a diaper change, and 108.9 s for tube feeding. The accuracy of the system was 95% for training and 85% for the validation dataset. In neonates 2, and, for neonates ≥32 weeks’ gestation, patting and tube feeding were associated with significant changes in HR. The presented system can classify and document the manipulations with high accuracy. Moreover, the study suggests that manipulations impact physiological parameters.
- 1 November 2015
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 102 (5) , 1030-1034
Latent iron deficiency at birth influences auditory neural maturation in late preterm and term infants
Background: In utero latent iron deficiency has been associated with abnormal neurodevelopmental outcomes during childhood. Its concomitant effect on auditory neural maturation has not been well studied in late preterm and term infants.
- 1 November 2015
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 102 (5) , 1030-1034
Latent iron deficiency at birth influences auditory neural maturation in late preterm and term infants
Background: In utero latent iron deficiency has been associated with abnormal neurodevelopmental outcomes during childhood. Its concomitant effect on auditory neural maturation has not been well studied in late preterm and term infants.
- 1 May 2015
- Published by Elsevier in Resuscitation
- Vol. 90, 21-24
T-piece or self inflating bag for positive pressure ventilation during delivery room resuscitation: An RCT
- 1 May 2015
- Published by Elsevier in Resuscitation
- Vol. 90, 21-24
T-piece or self inflating bag for positive pressure ventilation during delivery room resuscitation: An RCT