Herman Kado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Herman Kado has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Christopher Ramos
2 shared publications- David J. Dexter
Department of Vascular Surgery, Sentara, Norfolk, VA (D.D.).
2 shared publications R. Dana Tomalty
2 shared publications- Sameh Sayfo
Department of Cardiovascular Medicine, Baylor Scott and White, The Heart Hospital, Plano, TX (S.S.).
2 shared publications - Abdullah Shaikh
Department of Radiology, Allegheny Health Network Research Institute, Pittsburgh, Pennsylvania
1 shared publication Adam Raskin
Mercy Heart Institute, Cincinnati, Ohio
1 shared publication
Latest Publications
- Open Access
- 1 November 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 18 (11) , e015815
Prospective Multicenter IDE Study of the Next-Generation Precision Aspiration Thrombectomy System for Intermediate-Risk Pulmonary Embolism: The SYMPHONY-PE Trial
BACKGROUND: Mechanical thrombectomy offers a promising alternative to thrombolytic-based approaches for reducing thrombus burden and right heart strain in acute pulmonary embolism. This pivotal Food and Drug Administration–approval trial evaluated the safety and efficacy of the Symphony Thrombectomy System (Imperative Care, Inc, Campbell, CA) in acute intermediate-risk pulmonary embolism. METHODS: Patients with intermediate-risk pulmonary embolism (systolic blood pressure ≥90 mm Hg; right ventricle-to-left ventricle ratio >0.9) were enrolled without roll-ins. The primary safety end point was the rate of major adverse events within 48 hours, defined as a composite of all-cause major bleeding, device-related mortality, and serious device-related events, adjudicated by an academic independent safety board. The primary efficacy end point was the core laboratory–assessed mean change in right ventricle-to-left ventricle ratio from baseline to 48 hours. Prespecified performance goals were set for both. Exploratory end points included immediate postprocedure change in mean pulmonary artery pressure and change in modified Miller index at 48 hours. Safety was assessed in the intention-to-treat cohort and efficacy in the modified intention-to-treat cohort, excluding patients receiving nonstudy device treatments. RESULTS: Between December 2023 and May 2025, 109 patients were treated at 17 US centers (intention-to-treat), with 106 in the modified intention-to-treat cohort. The major adverse events rate was 0.9% (1/109), with an upper 97.5% CI of 5.7%, meeting the P 0.20 performance goal ( P P <0.001. CONCLUSIONS: These data support the safety and effectiveness of the Symphony Thrombectomy System in patients with acute intermediate-risk pulmonary embolism. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT06062329.
- 1 November 2025
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 18 (11) , e015815
Open AccessProspective Multicenter IDE Study of the Next-Generation Precision Aspiration Thrombectomy System for Intermediate-Risk Pulmonary Embolism: The SYMPHONY-PE Trial
BACKGROUND: Mechanical thrombectomy offers a promising alternative to thrombolytic-based approaches for reducing thrombus burden and right heart strain in acute pulmonary embolism. This pivotal Food and Drug Administration–approval trial evaluated the safety and efficacy of the Symphony Thrombectomy System (Imperative Care, Inc, Campbell, CA) in acute intermediate-risk pulmonary embolism. METHODS: Patients with intermediate-risk pulmonary embolism (systolic blood pressure ≥90 mm Hg; right ventricle-to-left ventricle ratio >0.9) were enrolled without roll-ins. The primary safety end point was the rate of major adverse events within 48 hours, defined as a composite of all-cause major bleeding, device-related mortality, and serious device-related events, adjudicated by an academic independent safety board. The primary efficacy end point was the core laboratory–assessed mean change in right ventricle-to-left ventricle ratio from baseline to 48 hours. Prespecified performance goals were set for both. Exploratory end points included immediate postprocedure change in mean pulmonary artery pressure and change in modified Miller index at 48 hours. Safety was assessed in the intention-to-treat cohort and efficacy in the modified intention-to-treat cohort, excluding patients receiving nonstudy device treatments. RESULTS: Between December 2023 and May 2025, 109 patients were treated at 17 US centers (intention-to-treat), with 106 in the modified intention-to-treat cohort. The major adverse events rate was 0.9% (1/109), with an upper 97.5% CI of 5.7%, meeting the P 0.20 performance goal ( P P <0.001. CONCLUSIONS: These data support the safety and effectiveness of the Symphony Thrombectomy System in patients with acute intermediate-risk pulmonary embolism. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT06062329.
- Open Access
- 25 January 2024
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 20 (1) , 5-8
Balloon-Assisted Thrombin Injection of a Profunda Femoral Pseudoaneurysm Using Radial Access
The profunda femoral artery is an uncommon location for a pseudoaneurysm and is technically challenging to resolve with traditional techniques, such as ultrasound-guided compression or thrombin injection, owing to its deep anatomical location. Balloon-assisted thrombin injection (BATI) is a technique that has been shown to be effective using contralateral access for technically difficult pseudoaneurysms in high-risk surgical patients. We report a case of BATI using radial access in a patient with a profunda femoral artery pseudoaneurysm.
- 25 January 2024
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 20 (1) , 5-8
Open AccessBalloon-Assisted Thrombin Injection of a Profunda Femoral Pseudoaneurysm Using Radial Access
The profunda femoral artery is an uncommon location for a pseudoaneurysm and is technically challenging to resolve with traditional techniques, such as ultrasound-guided compression or thrombin injection, owing to its deep anatomical location. Balloon-assisted thrombin injection (BATI) is a technique that has been shown to be effective using contralateral access for technically difficult pseudoaneurysms in high-risk surgical patients. We report a case of BATI using radial access in a patient with a profunda femoral artery pseudoaneurysm.
- Open Access
- 22 February 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (2) , 100585
Safety and Effectiveness of Mechanical Thrombectomy From the Fully Enrolled Multicenter, Prospective CLOUT Registry
- 22 February 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (2) , 100585
Open AccessSafety and Effectiveness of Mechanical Thrombectomy From the Fully Enrolled Multicenter, Prospective CLOUT Registry