Minghao Zheng
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Minghao Zheng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jingfeng Wang
Tsinghua University,Department of Electrical Engineering,Beijing,China
2 shared publications - Kainan Chen
Department of Electrical Engineering, Tsinghua University, Beijing, China
2 shared publications - Liqiang Yuan
Department of Electrical Engineering, Tsinghua University, Beijing, China
2 shared publications - Zhengming Zhao
Department of Electrical Engineering, Tsinghua University, Beijing, China
2 shared publications - Chao Sheng
Sichuan Univ
1 shared publication - Di Mou
Department of Electrical Engineering, Tsinghua University, Beijing, China
1 shared publication
Latest Publications
- 8 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 129-134
An Automated Parameter Design Framework for Flexible Interconnection Devices in Distribution Networks
Flexible Interconnection Devices (FIDs) have various functions, such as power flow control, fault isolation, and power quality improvement, showing great potential for applications in distribution networks. Appropriate system parameters are crucial to ensure the normal operation and good performance of FID. However, the parameter design of FID includes multiple optimization objectives, multiple constraints and various operating modes, and traditional manual design methods face challenges under such complexity. This paper presents an efficient automated design framework for parameter design of FID, based on model simulation and genetic algorithm. The proposed framework reduces the burden of manual mathematical derivation and improves accuracy through purely simulation-based model solving, and multiple measures are taken to enhance the calculation speed. By employing genetic algorithm to deal with multiple optimization objectives and constraints, it caters to dual operating modes of FID and optimizes both main circuit parameters and control parameters to obtain a loss-volume Pareto frontier. The automated design results are validated through simulations, demonstrating significant advantages over traditional manual design methods.
- 8 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 129-134
An Automated Parameter Design Framework for Flexible Interconnection Devices in Distribution Networks
Flexible Interconnection Devices (FIDs) have various functions, such as power flow control, fault isolation, and power quality improvement, showing great potential for applications in distribution networks. Appropriate system parameters are crucial to ensure the normal operation and good performance of FID. However, the parameter design of FID includes multiple optimization objectives, multiple constraints and various operating modes, and traditional manual design methods face challenges under such complexity. This paper presents an efficient automated design framework for parameter design of FID, based on model simulation and genetic algorithm. The proposed framework reduces the burden of manual mathematical derivation and improves accuracy through purely simulation-based model solving, and multiple measures are taken to enhance the calculation speed. By employing genetic algorithm to deal with multiple optimization objectives and constraints, it caters to dual operating modes of FID and optimizes both main circuit parameters and control parameters to obtain a loss-volume Pareto frontier. The automated design results are validated through simulations, demonstrating significant advantages over traditional manual design methods.
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3086-3095
Seamless Entry Control Strategy for Redundant Modules of High-Frequency Bus Electric Energy Router
With the rapid development of renewable energy, high-frequency bus electric energy router that provides multiple ports for different sources and loads is gaining attention, and the application of redundant modules for electric energy router is necessary to improve the reliability of the system. However, the strong coupling characteristics of the common high-frequency bus structure can cause transient current dc bias and current fluctuation for redundant modules during the entry stage, which may result in overcurrent, device damage, and failed entry of redundant modules. This article proposes a partial module high-frequency current model to analyze the causes of transient current dc bias of redundant modules when entering into normal operation and designs a seamless entry control strategy for redundant modules to eliminate the current dc bias and achieve rapid entry into steady-state operation, which can remove the high-frequency current sampling process to simplify the control system. The feasibility of the proposed control strategy is verified by offline simulation and hardware-in-loop real-time simulation platform.
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3086-3095
Seamless Entry Control Strategy for Redundant Modules of High-Frequency Bus Electric Energy Router
With the rapid development of renewable energy, high-frequency bus electric energy router that provides multiple ports for different sources and loads is gaining attention, and the application of redundant modules for electric energy router is necessary to improve the reliability of the system. However, the strong coupling characteristics of the common high-frequency bus structure can cause transient current dc bias and current fluctuation for redundant modules during the entry stage, which may result in overcurrent, device damage, and failed entry of redundant modules. This article proposes a partial module high-frequency current model to analyze the causes of transient current dc bias of redundant modules when entering into normal operation and designs a seamless entry control strategy for redundant modules to eliminate the current dc bias and achieve rapid entry into steady-state operation, which can remove the high-frequency current sampling process to simplify the control system. The feasibility of the proposed control strategy is verified by offline simulation and hardware-in-loop real-time simulation platform.