Natalia Struzik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Natalia Struzik has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Maciej Dobrzyński
Department of Pediatric Dentistry and Preclinical Dentistry, Wrocław Medical University, Krakowska 26, 50-425 Wrocław, Poland
9 shared publications - Jacek Matys
Dental Surgery Department, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
8 shared publications - Kamila Wiśniewska
Dental Surgery Department, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
7 shared publications - Jan Kiryk
Dental Surgery Department, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
4 shared publications - Julia Kensy
Department of Pediatric Dentistry and Preclinical Dentistry, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
4 shared publications - Paweł J. Piszko
Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
3 shared publications
Latest Publications
- Open Access
SEM Evaluation of Surface Wear on Drills from Selected Implant Systems—In Vitro Study
Purpose: The aim of this in vitro study was to evaluate the degree of surface wear in implant drills from four commercial systems subjected to standardized osteotomy cycles. Materials: Four implant systems (Osstem, Megagen, Straumann, and Bego) were evaluated using sets of three drills of increasing diameters. A total of 120 osteotomies were performed in standardized porcine rib specimens under controlled drilling conditions (1200 rpm, continuous 4 °C saline irrigation, 32:1 reduction handpiece). After each drilling series, drills were cleaned, sterilized, and analyzed using SEM in three orientations. Wear was assessed using a seven-parameter scoring system. Multifactorial ANOVA, Pearson correlation, and hierarchical clustering were employed to evaluate the effects of drill brand, diameter, and wear patterns. Results: Both drill brand and diameter significantly influenced total wear scores (p < 0.001). Small-diameter pilot drills exhibited the highest wear, while large-diameter drills showed minimal degradation. Among the systems tested, Bego drills demonstrated the greatest overall wear, whereas Osstem drills—particularly the 2.0 mm drill—displayed unusually low wear for their size. A strong negative correlation between drill diameter and wear score was observed. Cluster analysis identified distinct wear patterns associated with specific drill sizes, with small drills showing prominent guide-face nicks and accumulation formation, medium drills exhibiting chipping and rake angle cleavage, and large drills presenting minimal wear. SEM imaging confirmed progressive surface deterioration, including edge rounding, microchipping, and irregular surface defects. Conclusions: Implant drill wear is strongly dependent on drill diameter, and cutting geometry. Small-diameter drills are most susceptible to surface degradation, which may increase friction and thermal load during osteotomy. Systems with enhanced material properties or optimized geometries demonstrated superior wear resistance. These findings highlight the importance of monitoring drill condition, adhering to recommended reuse limits, and considering advanced drill coatings or materials to ensure safe and predictable implant site preparation. Further research incorporating real-time thermal measurements and extended drilling cycles is needed to establish evidence-based guidelines for drill longevity and clinical performance.
Open AccessSEM Evaluation of Surface Wear on Drills from Selected Implant Systems—In Vitro Study
Purpose: The aim of this in vitro study was to evaluate the degree of surface wear in implant drills from four commercial systems subjected to standardized osteotomy cycles. Materials: Four implant systems (Osstem, Megagen, Straumann, and Bego) were evaluated using sets of three drills of increasing diameters. A total of 120 osteotomies were performed in standardized porcine rib specimens under controlled drilling conditions (1200 rpm, continuous 4 °C saline irrigation, 32:1 reduction handpiece). After each drilling series, drills were cleaned, sterilized, and analyzed using SEM in three orientations. Wear was assessed using a seven-parameter scoring system. Multifactorial ANOVA, Pearson correlation, and hierarchical clustering were employed to evaluate the effects of drill brand, diameter, and wear patterns. Results: Both drill brand and diameter significantly influenced total wear scores (p < 0.001). Small-diameter pilot drills exhibited the highest wear, while large-diameter drills showed minimal degradation. Among the systems tested, Bego drills demonstrated the greatest overall wear, whereas Osstem drills—particularly the 2.0 mm drill—displayed unusually low wear for their size. A strong negative correlation between drill diameter and wear score was observed. Cluster analysis identified distinct wear patterns associated with specific drill sizes, with small drills showing prominent guide-face nicks and accumulation formation, medium drills exhibiting chipping and rake angle cleavage, and large drills presenting minimal wear. SEM imaging confirmed progressive surface deterioration, including edge rounding, microchipping, and irregular surface defects. Conclusions: Implant drill wear is strongly dependent on drill diameter, and cutting geometry. Small-diameter drills are most susceptible to surface degradation, which may increase friction and thermal load during osteotomy. Systems with enhanced material properties or optimized geometries demonstrated superior wear resistance. These findings highlight the importance of monitoring drill condition, adhering to recommended reuse limits, and considering advanced drill coatings or materials to ensure safe and predictable implant site preparation. Further research incorporating real-time thermal measurements and extended drilling cycles is needed to establish evidence-based guidelines for drill longevity and clinical performance.
- Open Access
- 7 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8668
Effects of Laser Applications on Fibroblasts Cultured on Zirconia Surfaces—A Systematic Review
Background/Objectives: This systematic review aimed to evaluate and summarize the available evidence on the effects of light-based applications, including laser irradiation on fibroblast responses to zirconia surfaces. Methods: A comprehensive electronic search was performed in PubMed, Scopus, Web of Science, Embase, and WorldCat databases. After duplicate removal and eligibility screening, 17 studies met the inclusion criteria. Only in vitro and animal studies assessing fibroblast behavior on zirconia after light- or laser-based surface irradiation were included. Due to heterogeneity in study designs and parameters, data were qualitatively synthesized. Results: All included studies confirmed the biocompatibility of laser-modified zirconia surfaces. Various laser systems—including Er:YAG, Er,Cr:YSGG, Nd:YAG, diode, excimer, and femtosecond lasers—were investigated. Most studies reported enhanced fibroblast adhesion, proliferation, and cytoskeletal organization compared with untreated controls. Two of the included studies demonstrated an antibacterial effect of erbium lasers treatment on zirconia surfaces. However, outcomes varied depending on the laser parameters, irradiation energy, and zirconia type used. Conclusions: Laser-based surface modification of zirconia appears safe and biocompatible, with evidence indicating favorable effects on fibroblast adhesion, proliferation, and organization. While these findings are promising for optimizing soft-tissue integration around zirconia implant abutments, further standardized and long-term studies are necessary to determine optimal laser settings and confirm clinical applicability.
- 7 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8668
Open AccessEffects of Laser Applications on Fibroblasts Cultured on Zirconia Surfaces—A Systematic Review
Background/Objectives: This systematic review aimed to evaluate and summarize the available evidence on the effects of light-based applications, including laser irradiation on fibroblast responses to zirconia surfaces. Methods: A comprehensive electronic search was performed in PubMed, Scopus, Web of Science, Embase, and WorldCat databases. After duplicate removal and eligibility screening, 17 studies met the inclusion criteria. Only in vitro and animal studies assessing fibroblast behavior on zirconia after light- or laser-based surface irradiation were included. Due to heterogeneity in study designs and parameters, data were qualitatively synthesized. Results: All included studies confirmed the biocompatibility of laser-modified zirconia surfaces. Various laser systems—including Er:YAG, Er,Cr:YSGG, Nd:YAG, diode, excimer, and femtosecond lasers—were investigated. Most studies reported enhanced fibroblast adhesion, proliferation, and cytoskeletal organization compared with untreated controls. Two of the included studies demonstrated an antibacterial effect of erbium lasers treatment on zirconia surfaces. However, outcomes varied depending on the laser parameters, irradiation energy, and zirconia type used. Conclusions: Laser-based surface modification of zirconia appears safe and biocompatible, with evidence indicating favorable effects on fibroblast adhesion, proliferation, and organization. While these findings are promising for optimizing soft-tissue integration around zirconia implant abutments, further standardized and long-term studies are necessary to determine optimal laser settings and confirm clinical applicability.
- Open Access
Enhancing Osseointegration of Zirconia Implants Using Calcium Phosphate Coatings: A Systematic Review
Objective: Yttria-stabilized tetragonal zirconia polycrystal (Y-TZP), a variant of zirconia (ZrO2), has attracted interest as a substitute for titanium in dental and orthopedic implants, valued for its biocompatibility and aesthetics that resemble natural teeth. However, its bioinert surface limits osseointegration, making surface modifications such as calcium phosphate (CaP) coatings highly relevant. Materials and methods: The review process adhered to the PRISMA guidelines. Electronic searches of PubMed, Scopus, Web of Science, Embase, and Cochrane Library (July 2025) identified studies evaluating CaP-coated zirconia implants. Eligible studies included in vitro, in vivo, and preclinical investigations with a control group. Data on coating type, deposition method, and biological outcomes were extracted and analyzed. Results: A total of 27 studies were analyzed, featuring different calcium phosphate (CaP) coatings including β-tricalcium phosphate (β-TCP), hydroxyapatite (HA), octacalcium phosphate (OCP), and various composites. These coatings were applied using diverse techniques such as RF magnetron sputtering, sol–gel processing, biomimetic methods, and laser-based approaches. In multiple investigations, calcium phosphate coatings enhanced osteoblast attachment, proliferation, alkaline phosphatase (ALP) expression, and bone-to-implant contact (BIC) relative to unmodified zirconia surfaces. Multifunctional coatings incorporating growth factors, antibiotics, or nanoparticles showed additional benefits. Conclusion: CaP coatings enhance the bioactivity of zirconia implants and represent a promising strategy to overcome their inertness. Further standardized approaches and long-term studies are essential to verify their translational relevance.
Open AccessEnhancing Osseointegration of Zirconia Implants Using Calcium Phosphate Coatings: A Systematic Review
Objective: Yttria-stabilized tetragonal zirconia polycrystal (Y-TZP), a variant of zirconia (ZrO2), has attracted interest as a substitute for titanium in dental and orthopedic implants, valued for its biocompatibility and aesthetics that resemble natural teeth. However, its bioinert surface limits osseointegration, making surface modifications such as calcium phosphate (CaP) coatings highly relevant. Materials and methods: The review process adhered to the PRISMA guidelines. Electronic searches of PubMed, Scopus, Web of Science, Embase, and Cochrane Library (July 2025) identified studies evaluating CaP-coated zirconia implants. Eligible studies included in vitro, in vivo, and preclinical investigations with a control group. Data on coating type, deposition method, and biological outcomes were extracted and analyzed. Results: A total of 27 studies were analyzed, featuring different calcium phosphate (CaP) coatings including β-tricalcium phosphate (β-TCP), hydroxyapatite (HA), octacalcium phosphate (OCP), and various composites. These coatings were applied using diverse techniques such as RF magnetron sputtering, sol–gel processing, biomimetic methods, and laser-based approaches. In multiple investigations, calcium phosphate coatings enhanced osteoblast attachment, proliferation, alkaline phosphatase (ALP) expression, and bone-to-implant contact (BIC) relative to unmodified zirconia surfaces. Multifunctional coatings incorporating growth factors, antibiotics, or nanoparticles showed additional benefits. Conclusion: CaP coatings enhance the bioactivity of zirconia implants and represent a promising strategy to overcome their inertness. Further standardized approaches and long-term studies are essential to verify their translational relevance.
- Top Cited PapersOpen Access
Endodontic Sealers and Innovations to Enhance Their Properties: A Current Review
Endodontic sealers are crucial for achieving an effective root canal obturation, preventing reinfection and promoting long-term treatment success. This review categorizes sealers by chemical composition, including traditional types such as zinc oxide-eugenol, glass ionomer, silicone, methacrylate and epoxy resins, calcium hydroxide, and the latest bioceramic formulations. Each type is evaluated for its physicochemical properties, biocompatibility, sealing ability, antimicrobial activity, and clinical limitations. A significant focus is placed on recent research into modifications of these materials with antimicrobial agents, aimed at improving antibacterial properties, bioactivity, and sealing performance. Among these, chitosan emerges as the most promising additive due to its broad antimicrobial spectrum, low cytotoxicity, and enhancement of sealing capacity. While bioceramic sealers represent a notable advancement due to their bioactivity and favorable interaction with moist environments, concerns regarding potential neurotoxicity and retreatability remain. The article presents recent advancements in the enhancement of endodontic sealers through the incorporation of organic and inorganic additives. It further delineates key research priorities, particularly the integration of bioactive materials, nanotechnology, and naturally derived compounds, with an emphasis on their potential applications in pediatric endodontics. Overall, while contemporary sealers offer a wide range of benefits, continued innovation is needed to optimize their biological safety, mechanical performance, and clinical usability.
Top Cited PapersOpen AccessEndodontic Sealers and Innovations to Enhance Their Properties: A Current Review
Endodontic sealers are crucial for achieving an effective root canal obturation, preventing reinfection and promoting long-term treatment success. This review categorizes sealers by chemical composition, including traditional types such as zinc oxide-eugenol, glass ionomer, silicone, methacrylate and epoxy resins, calcium hydroxide, and the latest bioceramic formulations. Each type is evaluated for its physicochemical properties, biocompatibility, sealing ability, antimicrobial activity, and clinical limitations. A significant focus is placed on recent research into modifications of these materials with antimicrobial agents, aimed at improving antibacterial properties, bioactivity, and sealing performance. Among these, chitosan emerges as the most promising additive due to its broad antimicrobial spectrum, low cytotoxicity, and enhancement of sealing capacity. While bioceramic sealers represent a notable advancement due to their bioactivity and favorable interaction with moist environments, concerns regarding potential neurotoxicity and retreatability remain. The article presents recent advancements in the enhancement of endodontic sealers through the incorporation of organic and inorganic additives. It further delineates key research priorities, particularly the integration of bioactive materials, nanotechnology, and naturally derived compounds, with an emphasis on their potential applications in pediatric endodontics. Overall, while contemporary sealers offer a wide range of benefits, continued innovation is needed to optimize their biological safety, mechanical performance, and clinical usability.
- Open Access
- 21 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2161
Comparative Analysis of the Histological Characteristics of Bone Tissue Following Implant Drill Preparation Under Various Parameters: An In Vitro Study
Purpose: This study aimed to compare the histological characteristics of bone tissue following drilling with three implant systems under different rotational speeds and cooling conditions. Methods: A total of 54 implant bed preparations were performed in four swine ribs using three implant systems: Hiossen ET (Hiossen, Fairfield, NJ, USA), Paltop (Burlington, MA, USA), and Anyridge (Megagen, Daegu, Republic of Korea). Drilling was performed at three speeds (800, 1200, and 1500 rpm) under three cooling conditions: saline at room temperature, saline cooled to 4 °C, and no cooling. Histological evaluation was conducted using a Nikon Eclipse 80i fluorescence microscope (Nikon, Tokyo, Japan) with DAPI and rhodamine staining. Observations were performed at 40× magnification, focusing on the osteotomy wall and surrounding tissue. The samples were assessed based on surface smoothness, compressed tissue presence, carbonization, and adjacent tissue damage. Statistical analysis was performed using the Kruskal-Wallis test with Dunn’s post hoc comparisons to evaluate differences among experimental conditions. Results: The results demonstrated that the Hiossen ET system achieved optimal bone bed quality at 1200 rpm with saline cooling at 4 °C, producing the smoothest osteotomy walls and minimal thermal damage (p = 0.003). The Paltop system performed best at 800 rpm with 4 °C cooling, showing reduced tissue compression and fewer microcracks (p = 0.012). The Anyridge system exhibited the most favorable outcomes at 1200 rpm with saline cooling at room temperature, minimizing soft tissue remnants and preserving bone integrity (p = 0.021). Across all systems, the absence of cooling significantly increased thermal damage, carbonization, and tissue fragmentation, particularly at 1500 rpm (p < 0.001). Conclusions: The use of lower rotational speeds with effective cooling minimized tissue trauma and improved bone bed integrity. Further clinical validation is necessary to confirm the applicability of these results in human bone.
- 21 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2161
Open AccessComparative Analysis of the Histological Characteristics of Bone Tissue Following Implant Drill Preparation Under Various Parameters: An In Vitro Study
Purpose: This study aimed to compare the histological characteristics of bone tissue following drilling with three implant systems under different rotational speeds and cooling conditions. Methods: A total of 54 implant bed preparations were performed in four swine ribs using three implant systems: Hiossen ET (Hiossen, Fairfield, NJ, USA), Paltop (Burlington, MA, USA), and Anyridge (Megagen, Daegu, Republic of Korea). Drilling was performed at three speeds (800, 1200, and 1500 rpm) under three cooling conditions: saline at room temperature, saline cooled to 4 °C, and no cooling. Histological evaluation was conducted using a Nikon Eclipse 80i fluorescence microscope (Nikon, Tokyo, Japan) with DAPI and rhodamine staining. Observations were performed at 40× magnification, focusing on the osteotomy wall and surrounding tissue. The samples were assessed based on surface smoothness, compressed tissue presence, carbonization, and adjacent tissue damage. Statistical analysis was performed using the Kruskal-Wallis test with Dunn’s post hoc comparisons to evaluate differences among experimental conditions. Results: The results demonstrated that the Hiossen ET system achieved optimal bone bed quality at 1200 rpm with saline cooling at 4 °C, producing the smoothest osteotomy walls and minimal thermal damage (p = 0.003). The Paltop system performed best at 800 rpm with 4 °C cooling, showing reduced tissue compression and fewer microcracks (p = 0.012). The Anyridge system exhibited the most favorable outcomes at 1200 rpm with saline cooling at room temperature, minimizing soft tissue remnants and preserving bone integrity (p = 0.021). Across all systems, the absence of cooling significantly increased thermal damage, carbonization, and tissue fragmentation, particularly at 1500 rpm (p < 0.001). Conclusions: The use of lower rotational speeds with effective cooling minimized tissue trauma and improved bone bed integrity. Further clinical validation is necessary to confirm the applicability of these results in human bone.
- Open Access
- 13 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8266
Contamination in Bone Substitute Materials: A Systematic Review
Objective: Bone augmentation has become a significant practice in various areas of bone regeneration dentistry. This systematic review analyzes the research focused on evaluating bone substitute materials for the presence of contaminants. Methods: In June 2024, an extensive electronic search was conducted using renowned databases such as PubMed, Web of Science, and Scopus. Specific keywords employed in the search included ((bone AND (substitute) AND (remnants OR (purity)) OR ((graft AND tooth) AND (remnants OR purity)) OR ((graft AND dentin) AND (remnants OR purity)). The search adhered to the PRISMA protocol and the PICO framework. The review concentrated on the origin of bone substitute materials, the processing methods used for these materials, techniques for assessing purity, and types of contamination identified. A total of 594 articles were identified of which 22 met the criteria and were incorporated into the review. Results: Investigations into allogeneic and xenogeneic bone substitute materials have revealed that, despite manufacturers’ assurances of purity, some materials still contain contaminants. Sample analyses demonstrated the presence of donor cellular remains, cellular debris, intertrabecular fat, connective tissue, and collagen. Similarly, synthetically produced bone substitute materials (alloplastic materials) contained various impurities, such as polyvinyl alcohol (PVA), CaO phases, calcium-deficient HAp phases, oily substances containing carbon and silicone, cellulose derivatives, alpha-tricalcium phosphate (α-TCP), and heavy metals. Conclusions: Bone-derived and bone-like graft materials can contain various organic and inorganic impurities.
- 13 September 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (18) , 8266
Open AccessContamination in Bone Substitute Materials: A Systematic Review
Objective: Bone augmentation has become a significant practice in various areas of bone regeneration dentistry. This systematic review analyzes the research focused on evaluating bone substitute materials for the presence of contaminants. Methods: In June 2024, an extensive electronic search was conducted using renowned databases such as PubMed, Web of Science, and Scopus. Specific keywords employed in the search included ((bone AND (substitute) AND (remnants OR (purity)) OR ((graft AND tooth) AND (remnants OR purity)) OR ((graft AND dentin) AND (remnants OR purity)). The search adhered to the PRISMA protocol and the PICO framework. The review concentrated on the origin of bone substitute materials, the processing methods used for these materials, techniques for assessing purity, and types of contamination identified. A total of 594 articles were identified of which 22 met the criteria and were incorporated into the review. Results: Investigations into allogeneic and xenogeneic bone substitute materials have revealed that, despite manufacturers’ assurances of purity, some materials still contain contaminants. Sample analyses demonstrated the presence of donor cellular remains, cellular debris, intertrabecular fat, connective tissue, and collagen. Similarly, synthetically produced bone substitute materials (alloplastic materials) contained various impurities, such as polyvinyl alcohol (PVA), CaO phases, calcium-deficient HAp phases, oily substances containing carbon and silicone, cellulose derivatives, alpha-tricalcium phosphate (α-TCP), and heavy metals. Conclusions: Bone-derived and bone-like graft materials can contain various organic and inorganic impurities.
- Open Access
- 20 August 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (8) , 503
Bone Regeneration Capabilities of Scaffolds Containing Chitosan and Nanometric Hydroxyapatite—Systematic Review Based on In Vivo Examinations
In this systematic review, the authors aimed to investigate the state of knowledge on in vivo evaluations of chitosan and nanometric hydroxyapatite (nanohydroxyapatite, nHAp) scaffolds for bone-tissue regeneration. In March 2024, an electronic search was systematically conducted across the PubMed, Cochrane, and Web of Science databases using the keywords (hydroxyapatite) AND (chitosan) AND (scaffold) AND (biomimetic). Methodologically, the systematic review followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) protocol to the letter. Initially, a total of 375 studies were screened, and 164 duplicates were removed. A further 188 articles were excluded because they did not correspond to the predefined topics, and an additional 3 articles were eliminated due to the inability to obtain the full text. The final compilation included 20 studies. All publications indicated a potential beneficial effect of the scaffolds in in vivo bone defect repair. A beneficial effect of hydroxyapatite as a scaffold component was observed in 16 studies, including greater mechanical resistance, cellular differentiation, and enhanced bone damage regeneration. The addition of chitosan and apatite ceramics, which combined the strengths of both materials, had the potential to become a useful bone-tissue engineering material.
- 20 August 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (8) , 503
Open AccessBone Regeneration Capabilities of Scaffolds Containing Chitosan and Nanometric Hydroxyapatite—Systematic Review Based on In Vivo Examinations
In this systematic review, the authors aimed to investigate the state of knowledge on in vivo evaluations of chitosan and nanometric hydroxyapatite (nanohydroxyapatite, nHAp) scaffolds for bone-tissue regeneration. In March 2024, an electronic search was systematically conducted across the PubMed, Cochrane, and Web of Science databases using the keywords (hydroxyapatite) AND (chitosan) AND (scaffold) AND (biomimetic). Methodologically, the systematic review followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) protocol to the letter. Initially, a total of 375 studies were screened, and 164 duplicates were removed. A further 188 articles were excluded because they did not correspond to the predefined topics, and an additional 3 articles were eliminated due to the inability to obtain the full text. The final compilation included 20 studies. All publications indicated a potential beneficial effect of the scaffolds in in vivo bone defect repair. A beneficial effect of hydroxyapatite as a scaffold component was observed in 16 studies, including greater mechanical resistance, cellular differentiation, and enhanced bone damage regeneration. The addition of chitosan and apatite ceramics, which combined the strengths of both materials, had the potential to become a useful bone-tissue engineering material.
- Open Access
- 7 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (12) , 4972
Discrepancies in Cephalometric Analysis Results between Orthodontists and Radiologists and Artificial Intelligence: A Systematic Review
Cephalometry is a crucial examination in orthodontic diagnostics and during the planning of orthognathic surgical procedures. The objective of this article was to compare cephalometric measurements conducted by different specialists and systems tailored for such measurements, as well as to evaluate the capabilities of artificial intelligence in this field. In January 2024, we conducted electronic searches in the PubMed, Scopus, and Web of Science (WoS) databases. In the Scopus database, the results were refined to titles, abstracts, and keywords, while in PubMed, they were narrowed down to titles and abstracts. In WoS, the results were refined only to abstracts. The search criteria were based on the following terms: (cephalometric) AND (analysis) AND (discrepancy) AND ((orthodontic) OR (radiologist)). A total of 263 articles were identified, of which 17 met the criteria and were incorporated into the review. The review allowed us to conclude that the accuracy of cephalometric measurements relied on the expertise of the operator—specialists with more experience exhibited greater precision compared to novices or individuals not specialized in orthodontics. Cephalometric measurement computer programs yielded outcomes that streamlined work processes, minimized human errors, and enhanced precision. A novel aspect involved the application of artificial intelligence, which also demonstrated high precision and a substantial reduction in working time, although its utilization still necessitates further enhancements. Further research was required to address these limitations and to optimize the incorporation of technology in orthodontic and orthognathic surgery practices.
- 7 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (12) , 4972
Open AccessDiscrepancies in Cephalometric Analysis Results between Orthodontists and Radiologists and Artificial Intelligence: A Systematic Review
Cephalometry is a crucial examination in orthodontic diagnostics and during the planning of orthognathic surgical procedures. The objective of this article was to compare cephalometric measurements conducted by different specialists and systems tailored for such measurements, as well as to evaluate the capabilities of artificial intelligence in this field. In January 2024, we conducted electronic searches in the PubMed, Scopus, and Web of Science (WoS) databases. In the Scopus database, the results were refined to titles, abstracts, and keywords, while in PubMed, they were narrowed down to titles and abstracts. In WoS, the results were refined only to abstracts. The search criteria were based on the following terms: (cephalometric) AND (analysis) AND (discrepancy) AND ((orthodontic) OR (radiologist)). A total of 263 articles were identified, of which 17 met the criteria and were incorporated into the review. The review allowed us to conclude that the accuracy of cephalometric measurements relied on the expertise of the operator—specialists with more experience exhibited greater precision compared to novices or individuals not specialized in orthodontics. Cephalometric measurement computer programs yielded outcomes that streamlined work processes, minimized human errors, and enhanced precision. A novel aspect involved the application of artificial intelligence, which also demonstrated high precision and a substantial reduction in working time, although its utilization still necessitates further enhancements. Further research was required to address these limitations and to optimize the incorporation of technology in orthodontic and orthognathic surgery practices.
- Open Access
- 29 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1107
SEM Studies Assessing the Efficacy of Laser Treatment for Primary Teeth: A Systematic Review
Treating and limiting caries among young children are crucial issues for pediatric dentistry. In our systematic review, the authors intend to assess alterations in the surfaces of primary teeth following laser treatment using Scanning Electron Microscopy (SEM). The aim of this article is to systematically review and consolidate existing knowledge regarding the use of SEM imaging to assess the efficacy of laser treatment for primary teeth. On 10 November 2023, an electronic search was systematically conducted across PubMed, Cochrane, Web of Science, and Scopus databases with keywords ((laser) AND ((primary teeth) OR (deciduous teeth)) AND (SEM)). The initial pool consisted of 205 records, from which 93 duplicates were eliminated. After careful examination of the remaining articles, 24 records were included in this systematic review. The majority of articles suggest that laser treatment provides dentinal surface without a smear layer, enhances remineralization of enamel, and improves the bonding quality of resin restorations. However, some discrepancies are still present. Based on the gathered articles, the authors of this review have concluded that laser treatment could be applied to deciduous teeth in terms of caries treatment and remineralization although further research is still needed.
- 29 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1107
Open AccessSEM Studies Assessing the Efficacy of Laser Treatment for Primary Teeth: A Systematic Review
Treating and limiting caries among young children are crucial issues for pediatric dentistry. In our systematic review, the authors intend to assess alterations in the surfaces of primary teeth following laser treatment using Scanning Electron Microscopy (SEM). The aim of this article is to systematically review and consolidate existing knowledge regarding the use of SEM imaging to assess the efficacy of laser treatment for primary teeth. On 10 November 2023, an electronic search was systematically conducted across PubMed, Cochrane, Web of Science, and Scopus databases with keywords ((laser) AND ((primary teeth) OR (deciduous teeth)) AND (SEM)). The initial pool consisted of 205 records, from which 93 duplicates were eliminated. After careful examination of the remaining articles, 24 records were included in this systematic review. The majority of articles suggest that laser treatment provides dentinal surface without a smear layer, enhances remineralization of enamel, and improves the bonding quality of resin restorations. However, some discrepancies are still present. Based on the gathered articles, the authors of this review have concluded that laser treatment could be applied to deciduous teeth in terms of caries treatment and remineralization although further research is still needed.