Tim Maecken
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tim Maecken has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Christina Marcon
1 shared publication- Daniel Radny
Department of Anaesthesiology and Intensive Care Medicine, St. Josef-Hospital, Ruhr-University Bochum, 44791 Bochum, Germany
1 shared publication - Georg Feigl
Institute of Anatomy and Clinical Morphology, Witten/Herdecke University, Witten, Germany
1 shared publication Michael Zenz
1 shared publication- Peter Schwarzkopf
Department for Anesthesiology, Intensive Care Medicine, Pain Therapy and Palliative Care, Sana Kliniken Leipziger Land GmbH, Borna, Germany
1 shared publication - Rainer J. Litz
Augsburg, Deutschland
1 shared publication
Latest Publications
- Open Access
Continuous Interscalene Brachial Plexus Blocks: An Anatomical Challenge between Scylla and Charybdis?
Brachial plexus blocks at the interscalene level are frequently chosen by physicians and recommended by textbooks for providing regional anesthesia and analgesia to patients scheduled for shoulder surgery. Published data concerning interscalene single-injection or continuous brachial plexus blocks report good analgesic effects. The principle of interscalene catheters is to extend analgesia beyond the duration of the local anesthetic’s effect through continuous infusion, as opposed to a single injection. However, in addition to the recognized beneficial effects of interscalene blocks, whether administered as a single injection or through a catheter, there have been reports of consequences ranging from minor side effects to severe, life-threatening complications. Both can be simply explained by direct mispuncture, as well as undesired local anesthetic spread or misplaced catheters. In particular, catheters pose a high risk when advanced or placed uncontrollably, a fact confirmed by reports of fatal outcomes. Secondary catheter dislocations explain side effects or loss of effectiveness that may occur hours or days after the initial correct function has been observed. From an anatomical and physiological perspective, this appears logical: the catheter tip must be placed near the plexus in an anatomically tight and confined space. Thus, the catheter’s position may be altered with the movement of the neck or shoulder, e.g., during physiotherapy. The safe use of interscalene catheters is therefore a balance between high analgesia quality and the control of side effects and complications, much like the passage between Scylla and Charybdis. We are convinced that the anatomical basis crucial for the brachial plexus block procedure at the interscalene level is not sufficiently depicted in the common regional anesthesia literature or textbooks. We would like to provide a comprehensive anatomical survey of the lateral neck, with special attention paid to the safe placement of interscalene catheters.
Open AccessContinuous Interscalene Brachial Plexus Blocks: An Anatomical Challenge between Scylla and Charybdis?
Brachial plexus blocks at the interscalene level are frequently chosen by physicians and recommended by textbooks for providing regional anesthesia and analgesia to patients scheduled for shoulder surgery. Published data concerning interscalene single-injection or continuous brachial plexus blocks report good analgesic effects. The principle of interscalene catheters is to extend analgesia beyond the duration of the local anesthetic’s effect through continuous infusion, as opposed to a single injection. However, in addition to the recognized beneficial effects of interscalene blocks, whether administered as a single injection or through a catheter, there have been reports of consequences ranging from minor side effects to severe, life-threatening complications. Both can be simply explained by direct mispuncture, as well as undesired local anesthetic spread or misplaced catheters. In particular, catheters pose a high risk when advanced or placed uncontrollably, a fact confirmed by reports of fatal outcomes. Secondary catheter dislocations explain side effects or loss of effectiveness that may occur hours or days after the initial correct function has been observed. From an anatomical and physiological perspective, this appears logical: the catheter tip must be placed near the plexus in an anatomically tight and confined space. Thus, the catheter’s position may be altered with the movement of the neck or shoulder, e.g., during physiotherapy. The safe use of interscalene catheters is therefore a balance between high analgesia quality and the control of side effects and complications, much like the passage between Scylla and Charybdis. We are convinced that the anatomical basis crucial for the brachial plexus block procedure at the interscalene level is not sufficiently depicted in the common regional anesthesia literature or textbooks. We would like to provide a comprehensive anatomical survey of the lateral neck, with special attention paid to the safe placement of interscalene catheters.
- 1 May 2011
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 28 (5) , 351-355
Relationship of the internal jugular vein to the common carotid artery: implications for ultrasound-guided vascular access
For cannulation of the internal jugular vein (IJV), ultrasound increases the number of first pass successes and reduces the rate of mechanical complications. A frequent complication of IJV access is the accidental injury of the common carotid artery (CCA), which can be dangerous in some circumstances. Landmarks and palpation of the CCA are used when ultrasound is not available. These conventional methods are based on the lateral position of the IJV to the CCA, and physicians traditionally employ head rotation to increase the success rates of IJV cannulation. Ultrasound scanning strictly from the anterior to posterior is not possible for this process because the probe must be adequately coupled to compensate for the curvature of the neck. Scans have been performed from different angles lateral to the neck, but misleadingly depict the relationship of the IJV to the CCA. In this study, the authors examined the effect of scanning at a 45° angle at the level of the cricoid on the depiction of the IJV in relation to the CCA. Furthermore, the influence of 30° head rotation to the contralateral side was also investigated. The relationship of the IJV to the CCA was recorded using ultrasound in 600 patients. Patients were placed in a supine position and the probe was coupled at the level of the cricoid, scanning at an angle of 45° from the lateral side of the neck. Based on the ultrasound images, the position of the IJV in relation to the CCA was recorded using a segmented grid. The centre of the vein (cross-section of the vertical and longitudinal diameter) determined the segment classification, in which the top of the ultrasound image was defined as the anterior. Additionally, in 300 patients, the head was rotated to the contralateral side at 30° to examine the impact of head rotation on the position of the IJV. The IJV was found in the lateral segment in only 3.0–3.3% of the patients. It was found in the anteromedial segment more frequently on the left side compared to the right side (P < 0.005). On the right side, the IJV was shown more frequently in the anterolateral position (P < 0.0001). Head rotation at 30° in 300 of the 600 patients caused a significant change of the IJV position in the left anteromedial segment, in that it frequently placed the IJV towards the anterior and anterolateral segment (P < 0.05). There was no significant impact of head rotation on the IJV representation on the right side. Atypical positions of the IJV (posterior, medial or thrombosis) were found in some cases. Ultrasound images used for IJV access usually depict the vein as being anterior to the CCA and only to a minor extent in the lateral position. This positioning is important for needle processing in order to avoid accidental arterial puncture and to identify atypical positions of the IJV. To determine the ideal puncture site, images of the neck vessels along their entire pathway should be obtained when using ultrasound for vascular access.
- 1 May 2011
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 28 (5) , 351-355
Relationship of the internal jugular vein to the common carotid artery: implications for ultrasound-guided vascular access
For cannulation of the internal jugular vein (IJV), ultrasound increases the number of first pass successes and reduces the rate of mechanical complications. A frequent complication of IJV access is the accidental injury of the common carotid artery (CCA), which can be dangerous in some circumstances. Landmarks and palpation of the CCA are used when ultrasound is not available. These conventional methods are based on the lateral position of the IJV to the CCA, and physicians traditionally employ head rotation to increase the success rates of IJV cannulation. Ultrasound scanning strictly from the anterior to posterior is not possible for this process because the probe must be adequately coupled to compensate for the curvature of the neck. Scans have been performed from different angles lateral to the neck, but misleadingly depict the relationship of the IJV to the CCA. In this study, the authors examined the effect of scanning at a 45° angle at the level of the cricoid on the depiction of the IJV in relation to the CCA. Furthermore, the influence of 30° head rotation to the contralateral side was also investigated. The relationship of the IJV to the CCA was recorded using ultrasound in 600 patients. Patients were placed in a supine position and the probe was coupled at the level of the cricoid, scanning at an angle of 45° from the lateral side of the neck. Based on the ultrasound images, the position of the IJV in relation to the CCA was recorded using a segmented grid. The centre of the vein (cross-section of the vertical and longitudinal diameter) determined the segment classification, in which the top of the ultrasound image was defined as the anterior. Additionally, in 300 patients, the head was rotated to the contralateral side at 30° to examine the impact of head rotation on the position of the IJV. The IJV was found in the lateral segment in only 3.0–3.3% of the patients. It was found in the anteromedial segment more frequently on the left side compared to the right side (P < 0.005). On the right side, the IJV was shown more frequently in the anterolateral position (P < 0.0001). Head rotation at 30° in 300 of the 600 patients caused a significant change of the IJV position in the left anteromedial segment, in that it frequently placed the IJV towards the anterior and anterolateral segment (P < 0.05). There was no significant impact of head rotation on the IJV representation on the right side. Atypical positions of the IJV (posterior, medial or thrombosis) were found in some cases. Ultrasound images used for IJV access usually depict the vein as being anterior to the CCA and only to a minor extent in the lateral position. This positioning is important for needle processing in order to avoid accidental arterial puncture and to identify atypical positions of the IJV. To determine the ideal puncture site, images of the neck vessels along their entire pathway should be obtained when using ultrasound for vascular access.