Sazuan Nazrah Mohd Azam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sazuan Nazrah Mohd Azam has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Arfah Syahida Mohd Nor
1 shared publication- Azizul Azizan
Faculty of Artificial Intelligence, Universiti Teknologi Malaysia (UTM), 54100 Kuala Lumpur, Malaysia
1 shared publication Ernadia Rosman
Faculty of Electrical Technology and Engineering Universiti Teknikal Malaysia Melaka
1 shared publicationHiew Rui Wen
Faculty of Electrical Technology and Engineering Universiti Teknikal Malaysia Melaka
1 shared publication- Mohd Hendra Hairi
Universiti Teknikal Malaysia Melaka
1 shared publication - Muhammad Iqbal Zakaria
Universiti Teknologi MARA
1 shared publication
Latest Publications
- Open Access
- 30 January 2026
- Published by Penerbit Universiti Malaysia Perlis in Journal of Engineering Research and Education (JERE)
- Vol. 17, 181-194
Liquid Level Control Performance Study of Conventional and Advanced Model-Based Controller for a Quadruple Tank System
Liquid level control in a quadruple tank system (QTS) is crucial for various industrialapplications due to its multivariable nature. Conventional controllers frequently encounterdifficulties maintaining performance in complex applications, showing transient and steadystateresponse difficulties. This study evaluates and compares the effectiveness of ModelPredictive Control (MPC) and Proportional-Integral-Derivative (PID) controller inregulating the liquid level of a quadruple tank system to improve control precision, stabilityand overall performance. The investigation utilized controller tuning to evaluateperformance metrics across different operational scenarios and constraints, including risetime, settling time, and overshoot. The results demonstrate that MPC has supersededperformance compared to PID controller, resulting in faster response time, shorter settlingtime, and decreased overshoot from the desired set point. As a result, constrained MPCachieved a 15% decrease in overshoot and a 20% decrease in settling time compared to thePID controller. To validate the robustness of MPC, set point changes were applied comparedwith PID controller performance metrics. MPC transitioned smoothly between 12 and 18 cmtargets without overshoot and steady-state error. In contrast, PID incurred a persistent 0.5cm error. This research contributes to the fact that MPC is a more effective method ofcontrolling QTS. MPC demonstrates better performance in both transient and steady-stateresponse.
- 30 January 2026
- Published by Penerbit Universiti Malaysia Perlis in Journal of Engineering Research and Education (JERE)
- Vol. 17, 181-194
Open AccessLiquid Level Control Performance Study of Conventional and Advanced Model-Based Controller for a Quadruple Tank System
Liquid level control in a quadruple tank system (QTS) is crucial for various industrialapplications due to its multivariable nature. Conventional controllers frequently encounterdifficulties maintaining performance in complex applications, showing transient and steadystateresponse difficulties. This study evaluates and compares the effectiveness of ModelPredictive Control (MPC) and Proportional-Integral-Derivative (PID) controller inregulating the liquid level of a quadruple tank system to improve control precision, stabilityand overall performance. The investigation utilized controller tuning to evaluateperformance metrics across different operational scenarios and constraints, including risetime, settling time, and overshoot. The results demonstrate that MPC has supersededperformance compared to PID controller, resulting in faster response time, shorter settlingtime, and decreased overshoot from the desired set point. As a result, constrained MPCachieved a 15% decrease in overshoot and a 20% decrease in settling time compared to thePID controller. To validate the robustness of MPC, set point changes were applied comparedwith PID controller performance metrics. MPC transitioned smoothly between 12 and 18 cmtargets without overshoot and steady-state error. In contrast, PID incurred a persistent 0.5cm error. This research contributes to the fact that MPC is a more effective method ofcontrolling QTS. MPC demonstrates better performance in both transient and steady-stateresponse.
- Open Access
- 19 June 2025
- Published by ASCEE Publications in International Journal of Robotics and Control Systems
- Vol. 5 (3) , 1758-1769
Formulation of a Lyapunov-Based PID Controller for Level Control of a Coupled-Tank System
This manuscript proposes a Proportional-Integral-Derivative (PID) control algorithm based on Lyapunov stability criteria. To verify the technique, the study is further extended to investigate its feasibility in controlling the liquid level of a coupled-tank system. A comparative study is conducted with the well-established Ziegler-Nichols tuning technique, known for its rapid and aggressive response. While Ziegler-Nichols often achieves quick tuning, it is prone to instability or degraded performance, particularly in systems with slow dynamics, such as the coupled-tank system. The results demonstrate the practical viability of the Lyapunov-based PID approach. The findings show that the Lyapunov-PID controller significantly outperforms the Ziegler-Nichols PID, achieving a 33.63% reduction in overshoot and a 45.14% improvement in settling time. These improvements highlight the advantage of incorporating Lyapunov-based criteria in PID design for systems where stability and performance are critical. However, the proposed approach has limitations such as increased computational complexity and the need for abstract tuning effort, along with difficulty in selecting appropriate Lyapunov functions.
- 19 June 2025
- Published by ASCEE Publications in International Journal of Robotics and Control Systems
- Vol. 5 (3) , 1758-1769
Open AccessFormulation of a Lyapunov-Based PID Controller for Level Control of a Coupled-Tank System
This manuscript proposes a Proportional-Integral-Derivative (PID) control algorithm based on Lyapunov stability criteria. To verify the technique, the study is further extended to investigate its feasibility in controlling the liquid level of a coupled-tank system. A comparative study is conducted with the well-established Ziegler-Nichols tuning technique, known for its rapid and aggressive response. While Ziegler-Nichols often achieves quick tuning, it is prone to instability or degraded performance, particularly in systems with slow dynamics, such as the coupled-tank system. The results demonstrate the practical viability of the Lyapunov-based PID approach. The findings show that the Lyapunov-PID controller significantly outperforms the Ziegler-Nichols PID, achieving a 33.63% reduction in overshoot and a 45.14% improvement in settling time. These improvements highlight the advantage of incorporating Lyapunov-based criteria in PID design for systems where stability and performance are critical. However, the proposed approach has limitations such as increased computational complexity and the need for abstract tuning effort, along with difficulty in selecting appropriate Lyapunov functions.
- 2 October 2024
- Published by Springer Nature
- p. 223-235
Convolutional Neural Networks Performance Study for Image Processing of Waste Segregation for Reverse Vending Machine
- 2 October 2024
- Published by Springer Nature
- p. 223-235
Convolutional Neural Networks Performance Study for Image Processing of Waste Segregation for Reverse Vending Machine
- Open Access
- 1 February 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (1) , 366-374
Accuracy study of image classification for reverse vending machine waste segregation using convolutional neural network
This study aims to create a sorting system with high accuracy that can classify various beverage containers based on types and separate them accordingly. This reverse vending machine (RVM) provides an image classification method and allows for recycling three types of beverage containers: drink carton boxes, polyethylene terephthalate (PET) bottles, and aluminium cans. The image classification method used in this project is transfer learning with convolutional neural networks (CNN). AlexNet, GoogLeNet, DenseNet201, InceptionResNetV2, InceptionV3, MobileNetV2, XceptionNet, ShuffleNet, ResNet 18, ResNet 50, and ResNet 101 are the neural networks that used in this project. This project will compare the F1-score and computational time among the eleven networks. The F1-score and computational time of image classification differs for each neural network. In this project, the AlexNet network gave the best F1-score, 97.50% with the shortest computational time, 2229.235 s among the eleven neural networks.
- 1 February 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (1) , 366-374
Open AccessAccuracy study of image classification for reverse vending machine waste segregation using convolutional neural network
This study aims to create a sorting system with high accuracy that can classify various beverage containers based on types and separate them accordingly. This reverse vending machine (RVM) provides an image classification method and allows for recycling three types of beverage containers: drink carton boxes, polyethylene terephthalate (PET) bottles, and aluminium cans. The image classification method used in this project is transfer learning with convolutional neural networks (CNN). AlexNet, GoogLeNet, DenseNet201, InceptionResNetV2, InceptionV3, MobileNetV2, XceptionNet, ShuffleNet, ResNet 18, ResNet 50, and ResNet 101 are the neural networks that used in this project. This project will compare the F1-score and computational time among the eleven networks. The F1-score and computational time of image classification differs for each neural network. In this project, the AlexNet network gave the best F1-score, 97.50% with the shortest computational time, 2229.235 s among the eleven neural networks.