Yinda Li
Yinda Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chongfeng Cao
Wuxi Power Filter Co., Ltd., Wuxi 214112, China
3 shared publications - Xiaowu Sun
Wuxi Power Filter Co., Ltd., Wuxi 214112, China
3 shared publications - Ying Qiao
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
3 shared publications - Cheng Yu
Wuxi Power Filter Co., Ltd., Wuxi 214112, China
1 shared publication - Jian Zhang
Wuxi Power Filter Co., Ltd., Wuxi 214112, China
1 shared publication - Shenrong Feng
Wuxi Power Filter Co., Ltd., Wuxi 214112, China
1 shared publication
Latest Publications
- Open Access
The Effect of Air Humidity on the Performance of DC Link Capacitor Components
DC link capacitors (DCLCs) are key devices in converters. The relative humidity affects the performance of the elements of a DCLC. Currently, there are relatively few studies on the effect of relative humidity on the electrical characteristics of the elements of DCLCs during the production process. This study describes the effects and the control of the relative humidity in the production process. For this purpose, a DCLC component withstand voltage test platform and a DCLC component aging test platform were established. The voltage withstand tests were conducted during different processes and at different relative humidities, and life aging tests were conducted at different relative humidities and different storage times. The results show that after the winding and metal-spraying processes, the voltage withstand levels of the components stored at 30% RH, 60% RH, and 80% RH were very close to that of the components at 3000 VDC; after the heat-setting process, the voltage withstand levels of the components stored at 30% RH, 60% RH, and 80% RH showed a decreasing tendency compared with the level of the components at 3000 VDC. Regarding the samples, after the heat-setting process, stored at 30% RH and 60% RH for 24 h, 96 h, 168 h, 240 h, and 336 h and 2000 h of the aging tests, the capacitance decreases monotonically as the storage time is increased but never exceeds 3%, and the capacitance change decreases as the relative humidity increases. This study can provide important guidance for the humidity control of various processes in the production of DCLCs.
Open AccessThe Effect of Air Humidity on the Performance of DC Link Capacitor Components
DC link capacitors (DCLCs) are key devices in converters. The relative humidity affects the performance of the elements of a DCLC. Currently, there are relatively few studies on the effect of relative humidity on the electrical characteristics of the elements of DCLCs during the production process. This study describes the effects and the control of the relative humidity in the production process. For this purpose, a DCLC component withstand voltage test platform and a DCLC component aging test platform were established. The voltage withstand tests were conducted during different processes and at different relative humidities, and life aging tests were conducted at different relative humidities and different storage times. The results show that after the winding and metal-spraying processes, the voltage withstand levels of the components stored at 30% RH, 60% RH, and 80% RH were very close to that of the components at 3000 VDC; after the heat-setting process, the voltage withstand levels of the components stored at 30% RH, 60% RH, and 80% RH showed a decreasing tendency compared with the level of the components at 3000 VDC. Regarding the samples, after the heat-setting process, stored at 30% RH and 60% RH for 24 h, 96 h, 168 h, 240 h, and 336 h and 2000 h of the aging tests, the capacitance decreases monotonically as the storage time is increased but never exceeds 3%, and the capacitance change decreases as the relative humidity increases. This study can provide important guidance for the humidity control of various processes in the production of DCLCs.
- Open Access
Insulation Resistance Characteristics of Dry DC Link Capacitors in the Presence of High Temperatures and Operating Voltages
Insulation resistance is a vital factor in dry DC link capacitors (DCLCs), and crucially influences their voltage equalization and energy storage performance. However, at present, there is a lack of experimental observation on the insulation resistance characteristics of DCLCs in the presence of high temperatures and operating voltages. In the present study, the insulation resistance and conductivity of DCLCs are methodically analyzed. For this purpose, the corresponding test platform is appropriately fabricated, the insulation resistance measurement experiments are performed at various temperatures and operating voltages, and the factors affecting the insulation resistance and conductivity of the DCLC are carefully examined. The results reveal that the insulation resistance of the DCLC reduces exponentially with the growth in voltage and operating temperature. When the operating voltage becomes greater than 4480 V or the operating temperature reaches higher than 70 °C, the decline in insulation resistance slows down. The conductivity of metalized polypropylene film in the DCLC increases exponentially with increasing voltage and temperature. By increasing the operating voltage from 1960 V to 5600 V and the temperature from 20 °C to 90 °C, the DCLC’s insulation resistance exhibits a descending trend from 891.30 MΩ to 2.14 MΩ, while its conductivity grows from 3.49 × 10−16 S/m to 1.47 × 10−13 S/m. The results reveal that the key factors affecting the insulation resistance of the DCLC are the polypropylene film and the metal evaporated from the metal layer. This research is anticipated to provide a valuable reference for the further development of science and technology pertinent to the insulation resistance of DCLCs.
Open AccessInsulation Resistance Characteristics of Dry DC Link Capacitors in the Presence of High Temperatures and Operating Voltages
Insulation resistance is a vital factor in dry DC link capacitors (DCLCs), and crucially influences their voltage equalization and energy storage performance. However, at present, there is a lack of experimental observation on the insulation resistance characteristics of DCLCs in the presence of high temperatures and operating voltages. In the present study, the insulation resistance and conductivity of DCLCs are methodically analyzed. For this purpose, the corresponding test platform is appropriately fabricated, the insulation resistance measurement experiments are performed at various temperatures and operating voltages, and the factors affecting the insulation resistance and conductivity of the DCLC are carefully examined. The results reveal that the insulation resistance of the DCLC reduces exponentially with the growth in voltage and operating temperature. When the operating voltage becomes greater than 4480 V or the operating temperature reaches higher than 70 °C, the decline in insulation resistance slows down. The conductivity of metalized polypropylene film in the DCLC increases exponentially with increasing voltage and temperature. By increasing the operating voltage from 1960 V to 5600 V and the temperature from 20 °C to 90 °C, the DCLC’s insulation resistance exhibits a descending trend from 891.30 MΩ to 2.14 MΩ, while its conductivity grows from 3.49 × 10−16 S/m to 1.47 × 10−13 S/m. The results reveal that the key factors affecting the insulation resistance of the DCLC are the polypropylene film and the metal evaporated from the metal layer. This research is anticipated to provide a valuable reference for the further development of science and technology pertinent to the insulation resistance of DCLCs.
- Open Access
Effects of Mechanical Stress on the Life and Insulation Performance of DC-Link Capacitors
Mechanical stress is a crucial factor affecting the life and insulation performance of DC-link capacitors (DCLCs). However, at present, there is a lack of long-term experimental observations on the effects of mechanical stress on the life and insulation performance of DCLCs. The element-winding process for DCLCs is carried out by winding metalized film on a reel and adjusting the various winding tensions and pressures according to performance requirements, usually with a winding tension coefficient (WTC) of kT = 1.5. The pull pressure of the winding machine on the film produces tension during the elements’ winding process, and the tension in the film grows after the heat-setting process. In this study, by adjusting the four tension coefficients of the elements in the winding process, which were 1.4, 1.5, 1.6, and 1.7, various winding tensions of the DCLC components were changed. Additionally, various heat-setting shrinkage tensions were appropriately generated by setting different heat-setting temperatures (HSTs). Relevant test platforms were established, and a life aging test, insulation resistance measurement, and withstand voltage test were performed on these DCLCs at different tension coefficients and HSTs. The obtained results reveal that the mechanical stress of DCLCs is affected by the parameters of the material itself, including the tension coefficient during the winding process and the HST. The winding tension affects the life of DCLCs, such that those with the highest tension (kT = 1.7) demonstrate the longest life at an HST of 105 °C, whereas samples with the lowest tension (kT = 1.4) exhibit the longest life at an HST of 110 °C. HSTs are capable of improving the lifetime of DCLCs. HSTs are also able to improve the withstand voltage capability of DCLCs, but the tension is not proportional to the withstand voltage capability of DCLCs. This research provides a suitable basis for further explorations of the life and insulation performance of DCLCs.
Open AccessEffects of Mechanical Stress on the Life and Insulation Performance of DC-Link Capacitors
Mechanical stress is a crucial factor affecting the life and insulation performance of DC-link capacitors (DCLCs). However, at present, there is a lack of long-term experimental observations on the effects of mechanical stress on the life and insulation performance of DCLCs. The element-winding process for DCLCs is carried out by winding metalized film on a reel and adjusting the various winding tensions and pressures according to performance requirements, usually with a winding tension coefficient (WTC) of kT = 1.5. The pull pressure of the winding machine on the film produces tension during the elements’ winding process, and the tension in the film grows after the heat-setting process. In this study, by adjusting the four tension coefficients of the elements in the winding process, which were 1.4, 1.5, 1.6, and 1.7, various winding tensions of the DCLC components were changed. Additionally, various heat-setting shrinkage tensions were appropriately generated by setting different heat-setting temperatures (HSTs). Relevant test platforms were established, and a life aging test, insulation resistance measurement, and withstand voltage test were performed on these DCLCs at different tension coefficients and HSTs. The obtained results reveal that the mechanical stress of DCLCs is affected by the parameters of the material itself, including the tension coefficient during the winding process and the HST. The winding tension affects the life of DCLCs, such that those with the highest tension (kT = 1.7) demonstrate the longest life at an HST of 105 °C, whereas samples with the lowest tension (kT = 1.4) exhibit the longest life at an HST of 110 °C. HSTs are capable of improving the lifetime of DCLCs. HSTs are also able to improve the withstand voltage capability of DCLCs, but the tension is not proportional to the withstand voltage capability of DCLCs. This research provides a suitable basis for further explorations of the life and insulation performance of DCLCs.