Jin-Hui Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jin-Hui Shen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Elan Z. Ahronovich
Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
1 shared publication Karen M. Joos
Vanderbilt University 2311 Pierce Avenue Nashville
1 shared publication- Nabil Simaan
Vanderbilt University
1 shared publication Ratna Prasad
Vanderbilt University 2311 Pierce Avenue Nashville
1 shared publicationTegy J. Vadakkan
Vanderbilt University Cell Imaging Shared Resources (CISR)
1 shared publication
Latest Publications
- 29 January 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (2) , 1150-1162
Five degrees-of-freedom mechanical arm with remote center of motion (RCM) device for volumetric optical coherence tomography (OCT) retinal imaging
Handheld optical coherence tomography (HH-OCT) is gaining popularity for diagnosing retinal diseases in neonates (e.g. retinopathy of prematurity). Diagnosis accuracy is degraded by hand tremor and patient motion when using commercially available handheld retinal OCT probes. This work presents a low-cost arm designed to address ergonomic challenges of holding a commercial OCT probe and alleviating hand tremor. Experiments with a phantom eye show enhanced geometric uniformity and volumetric accuracy when obtaining OCT scans with our device compared to handheld imaging approaches. An in-vivo porcine volumetric image was also obtained with the mechanical arm demonstrating clinical deployability.
- 29 January 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (2) , 1150-1162
Five degrees-of-freedom mechanical arm with remote center of motion (RCM) device for volumetric optical coherence tomography (OCT) retinal imaging
Handheld optical coherence tomography (HH-OCT) is gaining popularity for diagnosing retinal diseases in neonates (e.g. retinopathy of prematurity). Diagnosis accuracy is degraded by hand tremor and patient motion when using commercially available handheld retinal OCT probes. This work presents a low-cost arm designed to address ergonomic challenges of holding a commercial OCT probe and alleviating hand tremor. Experiments with a phantom eye show enhanced geometric uniformity and volumetric accuracy when obtaining OCT scans with our device compared to handheld imaging approaches. An in-vivo porcine volumetric image was also obtained with the mechanical arm demonstrating clinical deployability.