Rami Alanazi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rami Alanazi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Abass
Department of Materials, Design and Manufacturing Engineering, University of Liverpool, Liverpool L69 3GH, UK
5 shared publications - Jay Davies
Department of Materials, Design and Manufacturing Engineering, University of Liverpool, Liverpool L69 3GH, UK
4 shared publications - Lo-Yu Wu
Department of Optometry, Mackay Medical University, New Taipei 252, Taiwan
4 shared publications - Richard Wu
Research and Development Centre, Brighten Optix Corporation, Taipei 111, Taiwan
4 shared publications - Wen-Pin Lin
Department of Optometry, Mackay Medical University, New Taipei 252, Taiwan
4 shared publications - Arwa Fathy
Department of Engineering, University of Cambridge, Cambridge CB2 1PZ, UK
3 shared publications
Latest Publications
- Open Access
Are Soft Silicone Hydrogel Contact Lenses More Compliant in a Warm, Hydrated Environment?
Soft contact lenses are usually characterised at room temperature, yet they function on the eye at body temperature, where their mechanics and optical performance can change. This study investigated whether soft silicone hydrogel lenses become more compliant in a physiological environment. Two silicone hydrogel materials (Definitive 74 and Unisil) were tested at 24 °C and 35 °C using uniaxial tensile and compression methods, with Ogden hyperelastic models fitted and finite element analysis performed on a realistic eye model. Both materials became more compliant at 35 °C, with Definitive 74 showing a larger modulus decrease (0.40 to 0.32 MPa) than Unisil (0.73 to 0.70 MPa). Finite element simulations indicated that these temperature-driven changes in compliance significantly affected refractive power, especially when the lens base curve exceeded the corneal radius by more than 5%. These findings demonstrate that soft silicone hydrogel lenses are indeed more compliant in a warm, hydrated environment, highlighting the need for physiologically relevant testing to inform design, fitting strategies, comfort, and vision outcomes.
Open AccessAre Soft Silicone Hydrogel Contact Lenses More Compliant in a Warm, Hydrated Environment?
Soft contact lenses are usually characterised at room temperature, yet they function on the eye at body temperature, where their mechanics and optical performance can change. This study investigated whether soft silicone hydrogel lenses become more compliant in a physiological environment. Two silicone hydrogel materials (Definitive 74 and Unisil) were tested at 24 °C and 35 °C using uniaxial tensile and compression methods, with Ogden hyperelastic models fitted and finite element analysis performed on a realistic eye model. Both materials became more compliant at 35 °C, with Definitive 74 showing a larger modulus decrease (0.40 to 0.32 MPa) than Unisil (0.73 to 0.70 MPa). Finite element simulations indicated that these temperature-driven changes in compliance significantly affected refractive power, especially when the lens base curve exceeded the corneal radius by more than 5%. These findings demonstrate that soft silicone hydrogel lenses are indeed more compliant in a warm, hydrated environment, highlighting the need for physiologically relevant testing to inform design, fitting strategies, comfort, and vision outcomes.
- Open Access
- 6 October 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (10) , 1086
AI-Based Estimate of the Regional Effect of Orthokeratology Lenses on Tear Film Quality
Purpose: To investigate regional changes in tear film quality associated with orthokeratology (Ortho-K) lens wear using high-resolution spatial mapping and to evaluate the potential of artificial intelligence (AI) models in anticipating these changes. Methods: This study analysed tear film quality in 92 Ortho-K wearers divided into three groups based on lens wear duration (10–29 days, 30–90 days, and ≥91 days). Placido-based topographer measurement was used to generate regional tear film maps before and after treatment. A custom MATLAB pipeline enabled regional comparisons and statistical mapping. A feedforward neural network was trained to forecast local tear film quality using spatial data. Results: Single-value global mean metrics showed minimal changes in tear film quality across groups. However, regional mean mapping revealed significant mid-peripheral and peripheral deterioration over time, particularly in nasal and temporal corneal zones. These changes were often overlooked by global averaging and remained invisible through tear film breakup time (TBUT) measurements. The AI model predicted spatial tear quality with high accuracy (R ≥ 0.9 in testing), capturing nuanced regional variations. Conclusions: The regional analysis uncovers subtle, clinically relevant tear film disruptions caused by Ortho-K lens wear, particularly in peripheral areas. These insights challenge the adequacy of traditional single-value global mean assessments. The AI model demonstrates the potential for non-invasive, predictive evaluation of tear stability, supporting more personalised and effective Ortho-K care.
- 6 October 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (10) , 1086
Open AccessAI-Based Estimate of the Regional Effect of Orthokeratology Lenses on Tear Film Quality
Purpose: To investigate regional changes in tear film quality associated with orthokeratology (Ortho-K) lens wear using high-resolution spatial mapping and to evaluate the potential of artificial intelligence (AI) models in anticipating these changes. Methods: This study analysed tear film quality in 92 Ortho-K wearers divided into three groups based on lens wear duration (10–29 days, 30–90 days, and ≥91 days). Placido-based topographer measurement was used to generate regional tear film maps before and after treatment. A custom MATLAB pipeline enabled regional comparisons and statistical mapping. A feedforward neural network was trained to forecast local tear film quality using spatial data. Results: Single-value global mean metrics showed minimal changes in tear film quality across groups. However, regional mean mapping revealed significant mid-peripheral and peripheral deterioration over time, particularly in nasal and temporal corneal zones. These changes were often overlooked by global averaging and remained invisible through tear film breakup time (TBUT) measurements. The AI model predicted spatial tear quality with high accuracy (R ≥ 0.9 in testing), capturing nuanced regional variations. Conclusions: The regional analysis uncovers subtle, clinically relevant tear film disruptions caused by Ortho-K lens wear, particularly in peripheral areas. These insights challenge the adequacy of traditional single-value global mean assessments. The AI model demonstrates the potential for non-invasive, predictive evaluation of tear stability, supporting more personalised and effective Ortho-K care.
- Open Access
To Stitch or Not to Stitch, That Is the Question: Multi-Gaze Eye Topography Stitching Versus Single-Shot Profilometry
Purpose: To evaluate whether corneal topography map stitching can fully substitute the traditional single-shot capture methods in clinical settings. Methods: This record review study involved the measurement of corneal surfaces from 38 healthy subjects using two instruments: the Medmont Meridia, which employs a stitching composite topography method, and the Eye Surface Profiler (ESP), a single-shot measurement device. Data were processed separately for right and left eyes, with multiple gaze directions captured by the Medmont device. Surface registration and geometric transformation estimation, including neighbouring cubic interpolation, were applied to assess the accuracy of stitched maps compared to single-shot measurements. Results: The study evaluated eye rotation angles and surface alignment between Medmont topography across various gaze directions and ESP scans. Close eye rotations were found in the right-gaze, left-gaze and up-gaze directions, with rotation angles of around 8°; however, the down-gaze angle was around 15°, almost twice other gaze rotation angles. Root mean squared error (RMSE) analysis revealed notable discrepancies, particularly in the right-, left-, and up-gaze directions, with errors reaching up to 98 µm compared to ESP scans. Additionally, significance analyses showed that surface area ratios highlighted considerable differences, especially in the up-gaze direction, where discrepancies reached 70% for both right and left eyes. Conclusions: Despite potential benefits, the findings highlight a significant mismatch between stitched and single-shot measured surfaces due to digital processing artefacts. Findings suggest that stitching techniques, in their current form, are not yet ready to substitute single-shot topography measurements fully. Although stitching helps fit large-diameter contact lenses, care should be taken regarding the central area, especially if utilising the stitched data for optimising optics or wavefront analysis.
Open AccessTo Stitch or Not to Stitch, That Is the Question: Multi-Gaze Eye Topography Stitching Versus Single-Shot Profilometry
Purpose: To evaluate whether corneal topography map stitching can fully substitute the traditional single-shot capture methods in clinical settings. Methods: This record review study involved the measurement of corneal surfaces from 38 healthy subjects using two instruments: the Medmont Meridia, which employs a stitching composite topography method, and the Eye Surface Profiler (ESP), a single-shot measurement device. Data were processed separately for right and left eyes, with multiple gaze directions captured by the Medmont device. Surface registration and geometric transformation estimation, including neighbouring cubic interpolation, were applied to assess the accuracy of stitched maps compared to single-shot measurements. Results: The study evaluated eye rotation angles and surface alignment between Medmont topography across various gaze directions and ESP scans. Close eye rotations were found in the right-gaze, left-gaze and up-gaze directions, with rotation angles of around 8°; however, the down-gaze angle was around 15°, almost twice other gaze rotation angles. Root mean squared error (RMSE) analysis revealed notable discrepancies, particularly in the right-, left-, and up-gaze directions, with errors reaching up to 98 µm compared to ESP scans. Additionally, significance analyses showed that surface area ratios highlighted considerable differences, especially in the up-gaze direction, where discrepancies reached 70% for both right and left eyes. Conclusions: Despite potential benefits, the findings highlight a significant mismatch between stitched and single-shot measured surfaces due to digital processing artefacts. Findings suggest that stitching techniques, in their current form, are not yet ready to substitute single-shot topography measurements fully. Although stitching helps fit large-diameter contact lenses, care should be taken regarding the central area, especially if utilising the stitched data for optimising optics or wavefront analysis.
- Open Access
- 12 September 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (18) , 5420
Can AI Predict the Magnitude and Direction of Ortho-K Contact Lens Decentration to Limit Induced HOAs and Astigmatism?
Background: The aim is to investigate induced higher-order aberrations (HOA)s and astigmatism as a result of non-toric ortho-k lens decentration and utilise artificial intelligence (AI) to predict its magnitude and direction. Methods: Medmont E300 Video topographer was used to scan 249 corneas before and after ortho-k wear. Custom-built MATLAB codes extracted topography data and determined lens decentration from the boundary and midpoint of the central flattened treatment zone (TZ). An evaluation was carried out by conducting Zernike polynomial fittings via a computer-coded digital signal processing procedure. Finally, an AI-based machine learning neural network algorithm was developed to predict the direction and magnitude of TZ decentration. Results: Analysis of the first 21 Zernike polynomial coefficients indicate that the four low-order and four higher-order aberration terms were changed significantly by ortho-k wear. While baseline astigmatism was not correlated with lens decentration (R = 0.09), post-ortho-k astigmatism was moderately correlated with decentration (R = 0.38) and the difference in astigmatism (R = 0.3). Decentration was classified into three groups: ≤0.50 mm, reduced astigmatism by −0.9 ± 1 D; 0.5~1 mm, increased astigmatism by 0.8 ± 0.1 D; >1 mm, increased astigmatism by 2.7 ± 1.6 D and over 50% of lenses were decentred >0.5 mm. For lenses decentred >1 mm, 29.8% of right and 42.7% of left lenses decentred temporal-inferiorly and 13.7% of right and 9.4% of left lenses decentred temporal-superiorly. AI-based prediction successfully identified the decentration direction with accuracies of 70.2% for right and 71.8% for left lenses and predicted the magnitude of decentration with root-mean-square (RMS) of 0.31 mm and 0.25 mm for right and left eyes, respectively. Conclusions: Ortho-k lens decentration is common when fitting non-toric ortho-k lenses, resulting in induced HOAs and astigmatism, with the magnitude being related to the amount of decentration. AI-based algorithms can effectively predict decentration, potentially allowing for better control over ortho-k fitting and, thus, preferred clinical outcomes.
- 12 September 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (18) , 5420
Open AccessCan AI Predict the Magnitude and Direction of Ortho-K Contact Lens Decentration to Limit Induced HOAs and Astigmatism?
Background: The aim is to investigate induced higher-order aberrations (HOA)s and astigmatism as a result of non-toric ortho-k lens decentration and utilise artificial intelligence (AI) to predict its magnitude and direction. Methods: Medmont E300 Video topographer was used to scan 249 corneas before and after ortho-k wear. Custom-built MATLAB codes extracted topography data and determined lens decentration from the boundary and midpoint of the central flattened treatment zone (TZ). An evaluation was carried out by conducting Zernike polynomial fittings via a computer-coded digital signal processing procedure. Finally, an AI-based machine learning neural network algorithm was developed to predict the direction and magnitude of TZ decentration. Results: Analysis of the first 21 Zernike polynomial coefficients indicate that the four low-order and four higher-order aberration terms were changed significantly by ortho-k wear. While baseline astigmatism was not correlated with lens decentration (R = 0.09), post-ortho-k astigmatism was moderately correlated with decentration (R = 0.38) and the difference in astigmatism (R = 0.3). Decentration was classified into three groups: ≤0.50 mm, reduced astigmatism by −0.9 ± 1 D; 0.5~1 mm, increased astigmatism by 0.8 ± 0.1 D; >1 mm, increased astigmatism by 2.7 ± 1.6 D and over 50% of lenses were decentred >0.5 mm. For lenses decentred >1 mm, 29.8% of right and 42.7% of left lenses decentred temporal-inferiorly and 13.7% of right and 9.4% of left lenses decentred temporal-superiorly. AI-based prediction successfully identified the decentration direction with accuracies of 70.2% for right and 71.8% for left lenses and predicted the magnitude of decentration with root-mean-square (RMS) of 0.31 mm and 0.25 mm for right and left eyes, respectively. Conclusions: Ortho-k lens decentration is common when fitting non-toric ortho-k lenses, resulting in induced HOAs and astigmatism, with the magnitude being related to the amount of decentration. AI-based algorithms can effectively predict decentration, potentially allowing for better control over ortho-k fitting and, thus, preferred clinical outcomes.
- Open Access
- 1 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (2) , 148
Investigation of How Corneal Densitometry Artefacts Affect the Imaging of Normal and Keratoconic Corneas
Purpose: To investigate corneal densitometry artefacts found in Pentacam Scheimpflug scans and their potential effect on assessing keratoconic (KC) corneas compared to normal (N) corneas. Methods: The current study utilises Pentacam data of 458 N eyes, aged 35.6 ± 15.8 (range 10–87), referred to as the “N group”, and 314 KC eyes, aged 31.6 ± 10.8 (range 10–72), referred to as the “KC group”, where densitometry data were extracted and analysed via a custom-built MATLAB code. Radial summations of the densitometry were calculated at diameters ranging from 0.5 mm to 5.0 mm. The minimum normalised radial summation of densitometry (NRSD) value and angle were determined at each diameter and then linked. KC cone locations and areas of pathology were determined, and a comparison between N and KC groups was carried out both within the averaged area of pathology and over the corneal surface. Results: Joining minimum NRSD trajectory points marked a clear distortion line pointing to the nasal-superior direction at 65° from the nasal meridian. The findings were found to be independent of eye laterality or ocular condition. Consistency was detected in the right and left eyes among both the N and KC groups. The location of the KC cone centre and the area of pathology were determined, and the densitometry output was compared both within the area of pathology and over the whole cornea. When the average densitometry was compared between N and KC eyes within the KC area of pathology, the N group recorded a 16.37 ± 3.15 normalised grey-scale unit (NGSU), and the KC group recorded 17.74 ± 3.4 NGSU (p = 0.0001). However, when the whole cornea was considered, the N group recorded 16.71 ± 5.5 NGSU, and the KC group recorded 15.72 ± 3.98 NGSU (p = 0.0467). A weak correlation was found between the Bad D index and NGSU when the whole measured cornea was considered (R = −0.01); however, a better correlation was recorded within the KC area of pathology (R = 0.21). Conclusions: Nasal-superior artefacts are observed in the densitometry Pentacam maps, and analysis shows no significant differences in their appearance between N or KC corneas. When analysing KC corneas, it was found that the cone positions are mostly on the temporal-inferior side of the cornea, opposite to the densitometry artefact NRSD trajectory. The analysis suggests that the corneal densitometry artefacts do not interfere with the KC area of pathology as it reaches its extreme in the opposite direction; therefore, weighting the densitometry map to increase the contribution of the inferior-temporal cornea and decreasing that of the superior-nasal area would improve the classification or identification of KC if densitometry is to be used as a KC metric.
- 1 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (2) , 148
Open AccessInvestigation of How Corneal Densitometry Artefacts Affect the Imaging of Normal and Keratoconic Corneas
Purpose: To investigate corneal densitometry artefacts found in Pentacam Scheimpflug scans and their potential effect on assessing keratoconic (KC) corneas compared to normal (N) corneas. Methods: The current study utilises Pentacam data of 458 N eyes, aged 35.6 ± 15.8 (range 10–87), referred to as the “N group”, and 314 KC eyes, aged 31.6 ± 10.8 (range 10–72), referred to as the “KC group”, where densitometry data were extracted and analysed via a custom-built MATLAB code. Radial summations of the densitometry were calculated at diameters ranging from 0.5 mm to 5.0 mm. The minimum normalised radial summation of densitometry (NRSD) value and angle were determined at each diameter and then linked. KC cone locations and areas of pathology were determined, and a comparison between N and KC groups was carried out both within the averaged area of pathology and over the corneal surface. Results: Joining minimum NRSD trajectory points marked a clear distortion line pointing to the nasal-superior direction at 65° from the nasal meridian. The findings were found to be independent of eye laterality or ocular condition. Consistency was detected in the right and left eyes among both the N and KC groups. The location of the KC cone centre and the area of pathology were determined, and the densitometry output was compared both within the area of pathology and over the whole cornea. When the average densitometry was compared between N and KC eyes within the KC area of pathology, the N group recorded a 16.37 ± 3.15 normalised grey-scale unit (NGSU), and the KC group recorded 17.74 ± 3.4 NGSU (p = 0.0001). However, when the whole cornea was considered, the N group recorded 16.71 ± 5.5 NGSU, and the KC group recorded 15.72 ± 3.98 NGSU (p = 0.0467). A weak correlation was found between the Bad D index and NGSU when the whole measured cornea was considered (R = −0.01); however, a better correlation was recorded within the KC area of pathology (R = 0.21). Conclusions: Nasal-superior artefacts are observed in the densitometry Pentacam maps, and analysis shows no significant differences in their appearance between N or KC corneas. When analysing KC corneas, it was found that the cone positions are mostly on the temporal-inferior side of the cornea, opposite to the densitometry artefact NRSD trajectory. The analysis suggests that the corneal densitometry artefacts do not interfere with the KC area of pathology as it reaches its extreme in the opposite direction; therefore, weighting the densitometry map to increase the contribution of the inferior-temporal cornea and decreasing that of the superior-nasal area would improve the classification or identification of KC if densitometry is to be used as a KC metric.