RMRafael Monterreal

Rafael Monterreal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rafael Monterreal has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    More Efficient Heliostat Fields for Solar Tower Plants: The HELIOSUN Project

    by Jesus Ballestrin, Loreto Valenzuela, Jesús Fernandez-Reche, Ramón Pujol, Gabriel Cardona, José Carballo, Javier Bonilla, Noelia Estrenera-Pedriza, Elena Carra, Noelia Simal, et al.

    Heliostats could represent up to 60% of the investment cost for solar tower plants with more than 100 MWe of power, then reducing the cost of heliostats would have an important cost reduction of the plant. The Heliosun project approaches this cost reduction from three different perspectives. Firstly, an artificial vision system with object recognition is proposed, which allows the closed-loop tracking control of the heliostats. This system, consisting of the installation of a low-cost camera and processor in each one of the heliostats, will eliminate the positioning sensors and improve the tracking accuracy of heliostat, improving the concentrated solar radiation distribution on the solar receiver surface. Moreover, a correct measurement of the atmospheric attenuation suffered by the solar radiation concentrated by the heliostats on its way to the solar receiver, with distances greater than 1500m in large plants, will allow firstly, to perform an adequate selection of those sites with the best characteristics for the deployment of solar tower plants and to optimize the routine operation of the solar plant. Finally, a ray-tracing simulation software, based on OTSun, is intended to be developed, including a more accurate prediction of the behaviour of a solar tower plant with central receiver considering spectral analysis, as well as including all the experimental results presented above. These three approaches will allow to improve the operation of solar tower plants as a whole, optimizing the operation of the solar receiver and the solar field, increasing the technical and economic efficiency of these systems.

  • Open Access

    Testing and Validation of Innovative on-Site Solar Field Measurement Techniques to Increase Power Tower Plant Performance: The LEIA Project

    by Antonio Avila-Marin, Jesus Fernández-Reche, Rafael Monterreal, Jesus Ballestrin, Jose Fernando Gallego, Marina Casanova, Sonia Escorza, Amaia Mutuberria, Andreas Kämpgen, Ansgar Macke, et al.

    LEIA project aims to contribute to the development of the next generation of central receiver power plants focusing on validating a combination and integration of pre-commercial solar field control and O&M solutions for the central tower receiver technology using molten salts, as the most promising cost-effective solution with the highest market penetration potential. To effectively remove the existing technical and industrial barriers to optimize central receiver and heliostat field operation & maintenance and thus to improve overall CSP performance, the following innovations are being developed: 1) Smart heliostat field control, 2) Smart control systems, 3) Solar Field Operation and Maintenance control strategies. These developments will be tested and demonstrated in three flagship operational environments: a) Cerro Dominador (Chile), b) CIEMAT – PSA (Spain), and c) CENER – Tudela (Spain).


  • Open Access

    SolarPACES Task III Project: Analyze Heliostat Field:

    by Adrián Peña-Lapuente, Marcelino Sánchez, Charles-Alexis Asselineau, Kenneth Miguel Armijo, Marc Röger, Cristóbal Villasante, Jesús Fernández, Rafael Monterreal, Antonio Ávila-Marín, John Pye, et al.

    In recent years, great efforts have been made to reach a consensus on heliostat testing best practices. A specific SolarPACES task was launched to provide a Heliostat Testing Guidelines document for single heliostat evaluation with a focus on prototype validation and qualification. Such guidelines are not well-suited for heliostat evaluation in operating commercial heliostat fields. The commercial implementation of the Central Receiver technology is burdened by the lack of a demonstrated cost-effective methodology to test solar fields, particularly during the commissioning and operation phases of the plant. To address heliostat characterization challenges, the SolarPACES funded Project “Analyze Heliostat Field” aims to set the basis towards a SolarPACES guideline for Heliostat Field Performance testing under a common framework. This is by means of a review of the existing methodologies, R&D and industrial stakeholders information sharing and preparation of a future quantitative comparison and validation plan. As part of the development of this project, several meetings and a workshop involving the SolarPACES community was organized to share knowledge and experience in the measurement and characterization of heliostat fields using a range of technologies and procedures. Research centers and companies from 5 different and distant countries have actively participated in these meetings, sharing their experiences, needs and interests. This paper summarizes the outcome of this international collaborative effort and the prospects for future close collaborations sustained over time.


  • Open Access

    First Self-Aligned Heliostat Prototype at the Plataforma Solar de Almeria

    by Rafael Monterreal, Raúl Enrique, German Barrera, Ricardo Sanchez-Moreno, Tomás J. Reche, Jose Rodriguez

    It is a generally admitted fact that the optical aligning process of faceted heliostats in a Solar Power Tower Plant (SPTP), also called heliostat canting, introduces an assembly time penalization as well as a potential error in heliostat optics conformation [1, 2]. This double penalization influences both the solar field setup time and the optical quality of the SPTP. Aware of this fact, in 2014 the Plataforma Solar de Almeria (PSA) developed and patented a method to self-align facets and thus avoid the critical canting phase of a heliostat [3]. To experimentally demonstrate the feasibility of the self-aligning facet process, a small reflector composed of six facets and 9m2 of reflecting surface was designed and fabricated. The success of that experience has led to the development of a first 18.5m2 prototype of a self-aligned heliostat, which has been installed at the CESA-1 Heliostat Field (PSA) in 2022.

  • Open Access

    Design and Characterization of the New FAHEX100 Concentrator of PSA's SF60 Solar Furnace

    by José Rodriguez, Jose Galindo, Inmaculada Cañadas, Rafael Monterreal, Jesús Fernández Reche

    The facets of the old Mc Donnell Douglas concentrator of Plataforma Solar de Almería –PSA- SF60 solar furnace were degraded after thirty years of service, which had a great influence on its thermal response and efficiency, as the reflectivity decreased significantly due to the reflective surface being corroded and scratched. That is why, it was decided to replace them by new facets with higher reflectivity and better optical conditions. This paper describes the new facets, as well as the new support structure and the assembly and alignment of the concentrator facets. Finally, the technical characteristics of the new concentrator, and the power, size and flux distribution on the focus, are presented. For the new facets we selected a thin, hexagonal-shaped mirror bonded to an aluminum plate. Therefore, new facets with improved optical conditions were designed and manufactured and, for the assembly a new tubular structure was used to conform the new FAHEX100 concentrator To anticipate the behavior of the new FAHEX100 concentrator, a model was built in Tonatiuh, for which a geometric analysis of the facets was previously performed by means of photogrammetry. Once the facets were mounted on the concentrator, they were aligned by the Reverse Ilumination Method -RIM–, and the flux distribution on the focus was measured with a CCD camera. The performance of the SF60 solar furnace was improved significantly with the new FAHEX100 concentrator, including power, peak concentration, flux distribution on the focus, focus diameter and optical error σopt.