SHStanislav Honus

Stanislav Honus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stanislav Honus has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Boiling Heat Transfer on the Surface Made with Electro-Spark Deposition Technology

    by Stanislav Honus, Łukasz J. Orman, Norbert Radek

    The paper experimentally analyses heat transfer during water and ethanol boiling on an electro–spark deposited aluminum coating. The performance of this surface is compared with results for other microstructural coatings: laser-treated and meshed surfaces, as well as an electro-spark-deposited copper coating. The results indicate worse performance of the analysed electro-spark-deposited aluminum layer. However, electro-spark deposition could be a more durable option, because the microstructure-coated surfaces (laser–made and meshed heaters) may be prone to fouling, and their performance could deteriorate over time. Additionally, the accuracy of the selected boiling heat transfer model was considered concerning the analysed aluminum surface. Acceptable agreement between the calculated and experimental data is observed only at low heat flux values.

  • Open Access

    Thermal Comfort in Intelligent Buildings—The Impact of the CO2 Level on Thermal Sensations and the Development of a Modified Thermal Comfort Model

    by Łukasz J. Orman, Grzegorz Majewski, Stanislav Honus, Norbert Radek, Marek Telejko

    Providing comfortable environmental conditions in buildings requires energy. Thermal comfort depends on many factors, and successful prediction of thermal sensations based on physical parameters of indoor environment is a challenge. However, the issue is of significant importance because HVAC (heating, ventilation, air conditioning) systems consume considerable thermal and electrical energy and should be operated most efficiently to reduce energy needs while maintaining thermal comfort conditions. It is especially vital in intelligent buildings whose systems and services are large energy consumers. In this paper, a modified thermal comfort model (based on the large-scale questionnaire study conducted on intelligent buildings) is developed. It considers the impact of carbon dioxide, which was observed to be associated with higher thermal sensations with rising CO2 levels. The modification was based on the Box–Behnken method, which has never been performed in such studies. Modified correlations for PMV and PPD indexes proved more accurate than in the original model. Moreover, implications of the modification of this model with regard to energy consumption are discussed; however, this issue proved to be quite complicated as it involves not only input data of the physical indoor parameters but also subjective preferences of the respondents.

  • Open Access

    Analysis of Heat Pump and Photovoltaic Systems' Performance in the Residential Building

    by Luiza DęBska, Jan Krawczun, Jerzy Zb. Piotrowski, Stanislav Honus

    Renewable energy sources play a substantial role in the production of electricity and heat in single-family homes. This paper presents experimental data on electricity generation from a photovoltaic system with a maximum output of 9.9 kW, located on the rooftop of a building in the Swietokrzyskie Province. The obtained data are compared with the simulation software results and discussed. Electricity consumption and heat generation provided by the air source heat pump are analysed. The analysis also includes the coefficient of performance, which varied significantly by season, from 2.9 in February to ca. 5.5 in June. Moreover, the heat pump supplied about 90% of the thermal energy for heating (with the remaining about 10% used to heat domestic hot water), which closely agrees with data from a previous study in a different single-family building.


  • Open Access

    The impact of face masks on productivity and well-being in the smart building: The role of temperature as a moderating variable

    by Luiza DęBska, Łukasz Jan Orman, Norbert Radek, Jacek Pietraszek, Stanislav Honus, Jozef Bronček

    During the COVID-19 pandemic, the widespread use of face masks has become standard practice, raising questions about their impact on work efficiency. This paper examines the relationship between face mask use and subjectively assessed productivity and well-being of people in the smart educational...

  • Open Access

    Assessment of Indoor Air Quality, Overall Comfort and Humidity Preferences in Educational Buildings – Differences in Room Users' Perceptions

    by Natalia Siwczuk, Stanislav Honus, Lidia Dąbek

    This article presents an analysis of indoor air quality, overall comfort, and air humidity preferences in educational buildings, considering the subjective perceptions of occupants in the rooms. The results of measurements of microclimate parameters (air temperature, relative humidity) were compared with the occupants' subjective perceptions. The analyses of indoor environmental parameters focused on assessing differences in subjective assessment with regard to gender. The results show that, typically, more men than women considered their state (overall comfort) to be positive, and men were more likely to report slightly higher overall comfort than women at the same air temperature values. Generally speaking, women seemed to consider air quality poorer, while the relationship between overall comfort and indoor air quality was the same for women and men. Additionally, women seemed to rate the air humidity as drier.

  • Open Access

    Thermal Performance of Phase Change Copper Heat Exchangers Produced with the Laser Technology – Development of Model Modification

    by Łukasz J. Orman, Stanislav Honus, Norbert Radek, Marcin Kargul

    The boiling phenomenon that occurs on surfaces modified with the laser beam is very intense. The enhancement of heat flux in comparison to the unmodified surface is quite commonly reported in literature. However, a significant problem is the correct determination of heat flux dissipated from the laser-treated surfaces during pool boiling. This paper focuses on developing a modification of a model created by Rannenberg and Beer. It was initially proposed for a different type of microstructural coating, namely, wire meshes. The modified version of the model is used for predicting the heat flux transferred from laser-processed copper samples tested under boiling conditions of distilled water and ethyl alcohol. The modified correlation proved to provide reasonable accuracy in the analysed range of superheat values. The comparison of the experimental results and the results of the calculations made according to the modified model showed that the experimental points align along the qcalc = qexp line of ideal matching. Moreover, a great majority of the experimental points fall within the 100% error band.

  • Open Access

    Comparative analysis of boiling heat transfer on surfaces modified with thermal and mechanical techniques

    by Łukasz J. Orman, Norbert Radek, Stanislav Honus, Jacek Pietraszek

    Microstructural coatings enable large heat fluxes to be exchanged during nucleate boiling at small temperature differences. Such heat exchangers are highly efficient and can be used in various mechanical systems. The production techniques of selected types of microstructures (meshes, micro-fins, and longitudinal fins) are presented in the paper, with the main focus on the comparison of thermal performance of these heat-enhancing coatings during nucleate boiling of distilled water and ethyl alcohol. The comparison was done for the same structure height of ca. 0.90. The results indicate that generally, the highest performance was obtained with the laser–processed surface. The heat flux was even about 2.4 times higher for this type of structure than for the micro-fin surface. A modification to the selected model of boiling heat transfer on microstructural coatings was proposed and verified against the experimental data.


  • Open Access

    Assessment of Thermal Comfort in the Intelligent Building – Differences in Room Users' Perceptions

    by Natalia Siwczuk, Grzegorz Majewski, Jerzy Zb. Piotrowski, Stanislav Honus

    The article discusses possible differences in subjective assessment of thermal sensations of people in the intelligent building "Energis" of Kielce University of Technology with a focus on the impact of gender. The measurements took place in 52 educational rooms, during which 1143 questionnaire forms were collected from the respondents. Thermal sensation, acceptability, and preference votes were analyzed. The results indicate that women and men might perceive the indoor environment differently. Generally speaking, men seemed to rate colder environments as warmer, while hotter environments as cooler than female responses. However, the dependence of thermal preference vs. thermal sensation votes was almost identical for both genders, indicating the same character of perception of both parameters when they are considered together. Similarly, the highest thermal acceptability rating was recorded for the same range of thermal sensation votes from about -0.25 to +0.25 for both women and men.

  • Open Access

    Comparative Analysis of the Use of Renewable Energy Sources in Selected Single-family Houses

    by Luiza Dębska, Lidia Dąbek, Stanislav Honus, Krystian Szast, Jakub Szot

    Renewable energy sources play a substantial role in producing electricity and heat in single-family homes while becoming independent from external energy suppliers. This is primarily due to economic advantages, i.e., reducing electricity costs. This article aims to compare two single-family homes powered by photovoltaic systems and, additionally, a heat pump. Both buildings were located near each other in the same climate conditions (Swietokrzyskie Province, Poland). The analysis compared electricity production from the photovoltaic systems for two different module models with a maximum power of 280 W and 340 W for both buildings. Additionally, an analysis of electricity production was carried out for the monthly installation operation in the summer and autumn periods. The monthly electricity consumption from the heat pump in the autumn and winter periods was presented. In the last step, an economic analysis of the return on investment for both installations was presented. It turned out that despite the difference in investment costs, the payback period for both buildings is between 6-7 years.


  • Open Access

    Assessment of indoor environmental comfort for individuals wearing face masks of different thickness

    by Łukasz Jan Orman, Luiza DęBska, Lidia Dąbek, Stanislav Honus, Stanisław Adamczak

    The present paper experimentally analyses the subjective assessment of indoor environment comfort based on a questionnaire survey conducted in a climate chamber located at Kielce University of Technology (Poland), if two types of face masks are worn by the respondents: thin (medical) and thick (cotton-made) masks. Air temperature and relative humidity in the chamber ranged from around 19 to 28oC and 20 – 70%, respectively. Precise measurement of the microclimate parameters was obtained with a microclimate meter, which recorded air temperature and relative humidity at the moment of completing the questionnaires. The respondents were of similar age (22 – 31 years old) and wore two types of clothing during the experiments: summer and winter, which differed by thermal resistance. This value amounted to 0.5 clo for the summer outfit and 0.8 clo for the winter one.In total 960 questionnaires were analysed in the study. The results indicate that the increase in air temperature led to poorer overall comfort, while the largest comfort sensation was recorded for the most favourable thermal sensation range. In general, thicker masks provided lower overall comfort than thinner masks for all relative humidity values.