Simon Kersten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Simon Kersten has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Henning Taschke
44869 Bochum, Germany
3 shared publications- Michael Vorländer
Institute For Hearing Technology And Acoustics, RWTH Aachen University
3 shared publications Michael Vorländer
Institute for Hearing Technology and Acoustics, RWTH Aachen University, Aachen, Germany
2 shared publications- Franck Sgard
IRSST, Montréal, QC, Canada
1 shared publication - Janina Fels
Institute For Hearing Technology And Acoustics, RWTH Aachen University
1 shared publication - Matthias Blau
Institut für Hörtechnik und Audiologie, Jade Hochschule, Ofener Str. 16, 26121 Oldenburg, Germany
1 shared publication
Latest Publications
- Open Access
- 27 November 2025
- Published by EDP Sciences in Acta Acustica
- Vol. 9, 73
Methods to experimentally characterize the own-voice-generated objective occlusion effect induced by hearables
In this study, the problem of experimentally identifying the own-voice generated objective occlusion effect in hearables is addressed. Challenges arise from the sub-optimal properties of one’s own voice as a test signal, namely, poor reproducibility, limited bandwidth, and the induction of time-variant behavior of the effect being measured. Based on experiments with 19 participants wearing a vented hearable and producing running speech and a sung vowel, it was found that (a) running speech is better suited than vowels in most respects, except for the time-variance of the occlusion effect, (b) the use of transfer function-based estimates of the occlusion effect results in more problems than advantages in comparison to estimates based on power spectral densities, and (c) the popular method of measuring the occlusion effect by simultaneously measuring inside and outside the occluding device entails systematic errors of up to about 3–4 dB, even in the frequency range in which it was previously considered valid. In contrast, the simultaneous measurement with reference to the open contralateral ear is accurate throughout the frequency range in which an acceptable SNR is achieved.
- 27 November 2025
- Published by EDP Sciences in Acta Acustica
- Vol. 9, 73
Open AccessMethods to experimentally characterize the own-voice-generated objective occlusion effect induced by hearables
In this study, the problem of experimentally identifying the own-voice generated objective occlusion effect in hearables is addressed. Challenges arise from the sub-optimal properties of one’s own voice as a test signal, namely, poor reproducibility, limited bandwidth, and the induction of time-variant behavior of the effect being measured. Based on experiments with 19 participants wearing a vented hearable and producing running speech and a sung vowel, it was found that (a) running speech is better suited than vowels in most respects, except for the time-variance of the occlusion effect, (b) the use of transfer function-based estimates of the occlusion effect results in more problems than advantages in comparison to estimates based on power spectral densities, and (c) the popular method of measuring the occlusion effect by simultaneously measuring inside and outside the occluding device entails systematic errors of up to about 3–4 dB, even in the frequency range in which it was previously considered valid. In contrast, the simultaneous measurement with reference to the open contralateral ear is accurate throughout the frequency range in which an acceptable SNR is achieved.
- Open Access
- 1 October 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (4) , 3006-3016
On the sound pressure distribution in the inner ear induced by rigid body vibration
Intracochlear sound pressure measurements are essential for understanding inner ear function. During bone conduction (BC) stimulation, these pressures exhibit pronounced variability and similar magnitudes in the two scalae, making their interpretation challenging. These characteristics arise from the vibration of the entire inner ear and interactions between the different BC mechanisms. Using fundamental acoustic principles, we derive characteristics of intracochlear pressure distributions driven by fluid inertial effects from rigid body vibration of the inner ear. Our analysis shows that the vibration at a spatially uniform velocity in a single direction results in (1) proportionality of the pressure to stimulation velocity and frequency, (2) a linear pressure variation along the vibration direction, (3) uniform pressure in planes perpendicular to the motion, and (4) minimum pressure at a plane approximately aligned with the round window centroid. The superposition principle allows the extension of these results to any complex-valued amplitude vector of rigid body translation. The findings provide insights into the variability of experimental intracochlear sound pressure measurements and enhance the understanding of the interactions between the mechanisms involved in BC hearing.
- 1 October 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (4) , 3006-3016
Open AccessOn the sound pressure distribution in the inner ear induced by rigid body vibration
Intracochlear sound pressure measurements are essential for understanding inner ear function. During bone conduction (BC) stimulation, these pressures exhibit pronounced variability and similar magnitudes in the two scalae, making their interpretation challenging. These characteristics arise from the vibration of the entire inner ear and interactions between the different BC mechanisms. Using fundamental acoustic principles, we derive characteristics of intracochlear pressure distributions driven by fluid inertial effects from rigid body vibration of the inner ear. Our analysis shows that the vibration at a spatially uniform velocity in a single direction results in (1) proportionality of the pressure to stimulation velocity and frequency, (2) a linear pressure variation along the vibration direction, (3) uniform pressure in planes perpendicular to the motion, and (4) minimum pressure at a plane approximately aligned with the round window centroid. The superposition principle allows the extension of these results to any complex-valued amplitude vector of rigid body translation. The findings provide insights into the variability of experimental intracochlear sound pressure measurements and enhance the understanding of the interactions between the mechanisms involved in BC hearing.
- Open Access
- 12 February 2025
- Published by Elsevier in Hearing Research
- Vol. 459, 109205
Finite element analysis of the osseous spiral lamina’s influence on inner ear fluid flow during bone conduction stimulation
- 12 February 2025
- Published by Elsevier in Hearing Research
- Vol. 459, 109205
Open AccessFinite element analysis of the osseous spiral lamina’s influence on inner ear fluid flow during bone conduction stimulation
- Open Access
- 4 October 2024
- Published by Elsevier in Hearing Research
- Vol. 453, 109127
Influence of the cochlear partition’s flexibility on the macro mechanisms in the inner ear
- 4 October 2024
- Published by Elsevier in Hearing Research
- Vol. 453, 109127
Open AccessInfluence of the cochlear partition’s flexibility on the macro mechanisms in the inner ear
- Open Access
- 1 January 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (1) , 56-67
Impact of the ear canal motion on the impedance boundary conditions in models of the occlusion effect
The occlusion effect (OE) denotes the increased low-frequency perception of bone-conducted sounds when the ear canal (EC) is occluded. Circuit and finite element (FE) models are commonly used to investigate the OE and improve its prediction, often applying acoustic impedances at the EC entrance and tympanic membrane (TM). This study investigates the sound generation caused by the structural motion of the EC. In addition to the EC wall vibration, it accounts for the motions of the EC entrance and TM, resulting from nondeforming motion of the surrounding structures. A model extension including these motions with the impedances is proposed. Related mechanisms are illustrated based on a circuit model. Implications are discussed by using an EC motion extracted from a FE model of a human head. The results demonstrate that the motions of the EC entrance and TM, addressed by the proposed extension, affects the TM sound pressure and may lead to a reduction of the OE at lower frequencies compared to solely considering the EC wall vibration. Accordingly, this phenomenon potentially reconciles differences between experimental data and OE simulations at frequencies below about 250 Hz, highlighting the importance to discern between multiple contributing mechanisms to the TM sound pressure.
- 1 January 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (1) , 56-67
Open AccessImpact of the ear canal motion on the impedance boundary conditions in models of the occlusion effect
The occlusion effect (OE) denotes the increased low-frequency perception of bone-conducted sounds when the ear canal (EC) is occluded. Circuit and finite element (FE) models are commonly used to investigate the OE and improve its prediction, often applying acoustic impedances at the EC entrance and tympanic membrane (TM). This study investigates the sound generation caused by the structural motion of the EC. In addition to the EC wall vibration, it accounts for the motions of the EC entrance and TM, resulting from nondeforming motion of the surrounding structures. A model extension including these motions with the impedances is proposed. Related mechanisms are illustrated based on a circuit model. Implications are discussed by using an EC motion extracted from a FE model of a human head. The results demonstrate that the motions of the EC entrance and TM, addressed by the proposed extension, affects the TM sound pressure and may lead to a reduction of the OE at lower frequencies compared to solely considering the EC wall vibration. Accordingly, this phenomenon potentially reconciles differences between experimental data and OE simulations at frequencies below about 250 Hz, highlighting the importance to discern between multiple contributing mechanisms to the TM sound pressure.