Samuel Hopkins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Samuel Hopkins has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Zachary F. Lerner
Mechanical Engineering Department, Northern Arizona University, Flagstaff, AZ, USA
4 shared publications - Collin D. Bowersock
Human Performance and Nutrition Research Institute, Oklahoma State University, Stillwater, OK 74078, USA; Virginia Health Sciences at Old Dominion University, 5115 Hampton Blvd, Norfolk, VA 23529, USA
2 shared publications - Aayush Jain
Indian Institute of Technology (IIT) {nilaksh404 Kharagpur
1 shared publication - Amit Sahai
UCLA
1 shared publication - Boaz Barak
Harvard University
1 shared publication Connor Gaudette
Department of Mechanical Engineering, Northern Arizona University, Sanghi College of Engineering, Flagstaff, USA
1 shared publication
Latest Publications
- 20 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-14
Exploratory Assessment of Robotic Ankle Foot Orthosis Stiffness and Neutral Angle on Stair Ambulation in Individuals with Cerebral Palsy
Purpose Individuals who wear Ankle Foot Orthoses (AFOs) express a desire for adaptability and improved stair ambulation. This exploratory study examined how the stiffness and neutral angle of a robotic AFO influence stair ambulation and preference in spastic cerebral palsy (CP) and compared robotic AFOs, solid AFOs, and shoes alone. Methods Seven individuals with spastic CP completed modified Timed-Up-and-Down-Stairs (TUDS) tests under nine robotic AFO stiffness-neutral angle configurations, solid AFOs, and shoes alone. Outcomes included TUDS time, ankle kinematics, soleus and vastus lateralis activity, exertion, balance confidence, trunk instability, stiffness preference, and device power and torque. Mixed effects modeling assessed the effects of stiffness and neutral angle. Stiffness preference was evaluated during level walking, stair ascent, and descent. Repeated measures ANOVA compared robotic AFOs, solid AFOs, and shoes alone. Results Increased stiffness and more plantarflexed neutral angles decreased peak dorsiflexion (p < 0.05) and increased peak torque (p < 0.05). Few other outcomes were affected. Four of seven participants preferred low stiffness across all tasks. Robotic AFOs performed better than solid AFOs, by decreasing TUDs time (− 27%, d = − 0.66, p < 0.05) and increasing confidence (49%, d = 0.92, p < 0.05) in descent, but not better than shoes alone. During stair ascent, the only difference between the AFOs and shoes was a reduction in soleus activity between solid AFOs and shoes alone. Conclusion Robotic AFO configuration influences stair descent and may improve descent speed and confidence over solid AFOs in a limited sample of spastic CP.
- 20 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-14
Exploratory Assessment of Robotic Ankle Foot Orthosis Stiffness and Neutral Angle on Stair Ambulation in Individuals with Cerebral Palsy
Purpose Individuals who wear Ankle Foot Orthoses (AFOs) express a desire for adaptability and improved stair ambulation. This exploratory study examined how the stiffness and neutral angle of a robotic AFO influence stair ambulation and preference in spastic cerebral palsy (CP) and compared robotic AFOs, solid AFOs, and shoes alone. Methods Seven individuals with spastic CP completed modified Timed-Up-and-Down-Stairs (TUDS) tests under nine robotic AFO stiffness-neutral angle configurations, solid AFOs, and shoes alone. Outcomes included TUDS time, ankle kinematics, soleus and vastus lateralis activity, exertion, balance confidence, trunk instability, stiffness preference, and device power and torque. Mixed effects modeling assessed the effects of stiffness and neutral angle. Stiffness preference was evaluated during level walking, stair ascent, and descent. Repeated measures ANOVA compared robotic AFOs, solid AFOs, and shoes alone. Results Increased stiffness and more plantarflexed neutral angles decreased peak dorsiflexion (p < 0.05) and increased peak torque (p < 0.05). Few other outcomes were affected. Four of seven participants preferred low stiffness across all tasks. Robotic AFOs performed better than solid AFOs, by decreasing TUDs time (− 27%, d = − 0.66, p < 0.05) and increasing confidence (49%, d = 0.92, p < 0.05) in descent, but not better than shoes alone. During stair ascent, the only difference between the AFOs and shoes was a reduction in soleus activity between solid AFOs and shoes alone. Conclusion Robotic AFO configuration influences stair descent and may improve descent speed and confidence over solid AFOs in a limited sample of spastic CP.
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (5) , 5922-5929
A Machine Learning Framework for Activity Recognition With Robotic Ankle Foot Orthoses
Novel auto-adjusting ankle foot orthoses (AFOs) have been developed for individuals with cerebral palsy, stroke, or traumatic brain injury. These devices remedy the issue of poor adaptability in fixed stiffness AFOs. However, new controllers are needed to make robotic AFOs adaptable to different walking terrain and tasks. We embedded two machine learning models, Long-Short Term Memory (LSTM) and Random Forest (RF), in a robotic, adjustable AFO for stair ambulation classification. Pilot testing determined the minimum training data size to achieve F1 scores of 0.99 was 60 steps per class. Validation was conducted in six individuals with cerebral palsy (GMFCS I-II, Age 13–38) during training and testing periods that occurred outside standard lab environments. On average, the personalized RF models had 9% better accuracy and 34x faster speed than the personalized LSTM models. Personalized models yield 6-11% higher F1 scores than leave-one-out generalized models. These results demonstrate the feasibility for machine learning algorithms to be used in real-world activity recognition for an auto-adjusting AFO controller.
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (5) , 5922-5929
A Machine Learning Framework for Activity Recognition With Robotic Ankle Foot Orthoses
Novel auto-adjusting ankle foot orthoses (AFOs) have been developed for individuals with cerebral palsy, stroke, or traumatic brain injury. These devices remedy the issue of poor adaptability in fixed stiffness AFOs. However, new controllers are needed to make robotic AFOs adaptable to different walking terrain and tasks. We embedded two machine learning models, Long-Short Term Memory (LSTM) and Random Forest (RF), in a robotic, adjustable AFO for stair ambulation classification. Pilot testing determined the minimum training data size to achieve F1 scores of 0.99 was 60 steps per class. Validation was conducted in six individuals with cerebral palsy (GMFCS I-II, Age 13–38) during training and testing periods that occurred outside standard lab environments. On average, the personalized RF models had 9% better accuracy and 34x faster speed than the personalized LSTM models. Personalized models yield 6-11% higher F1 scores than leave-one-out generalized models. These results demonstrate the feasibility for machine learning algorithms to be used in real-world activity recognition for an auto-adjusting AFO controller.
- 14 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-15
Differential and Adjustable Stiffness Leaf Spring Ankle Foot Orthoses Enhance Gait Propulsion and Task Versatility in Cerebral Palsy
Purpose This study explored the effectiveness of a novel differential and adjustable stiffness leaf spring AFO (DAS-AFO) during standing, walking, and sit-to-stand tasks among individuals with cerebral palsy. Methods Eleven individuals with cerebral palsy, ages 12–41, completed treadmill walking trials with the DAS-AFO, a solid (i.e., rigid) AFO, and without an assistive device (shod). We quantified metabolic cost, muscle activity of the soleus and vastus lateralis, and lower body kinetics and kinematics. Participants also performed overground walking, sit-to-stand, and stable standing tasks while wearing the DAS-AFO and reported their preferred stiffness setting for each task. Additionally, we quantified center of pressure during the stable standing task. Results Walking with the DAS-AFO resulted in an average 24% increase in ankle push-off power when compared to the solid AFO (p = .003). Both AFO conditions resulted in an average 16% reduction in soleus activity compared to shod (p < .040); only the DAS-AFO reduced vastus lateralis activity compared to shod (13% average reduction, p = .015). Over half of the participants preferred a different AFO stiffness for at least one of the tasks of daily living. No stiffness setting was universally preferred for a single task. During the stable standing task, the high stiffness setting increased average anterior–posterior center of pressure excursion (p = .022) and velocity (p = .001) compared to shod. Conclusion Our findings highlight potential benefits of the DAS-AFO design over solid AFOs, including improved ankle joint motions and push-off power during walking. Customizability of the DAS-AFO positively influenced participant preference and task performance.
- 14 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-15
Differential and Adjustable Stiffness Leaf Spring Ankle Foot Orthoses Enhance Gait Propulsion and Task Versatility in Cerebral Palsy
Purpose This study explored the effectiveness of a novel differential and adjustable stiffness leaf spring AFO (DAS-AFO) during standing, walking, and sit-to-stand tasks among individuals with cerebral palsy. Methods Eleven individuals with cerebral palsy, ages 12–41, completed treadmill walking trials with the DAS-AFO, a solid (i.e., rigid) AFO, and without an assistive device (shod). We quantified metabolic cost, muscle activity of the soleus and vastus lateralis, and lower body kinetics and kinematics. Participants also performed overground walking, sit-to-stand, and stable standing tasks while wearing the DAS-AFO and reported their preferred stiffness setting for each task. Additionally, we quantified center of pressure during the stable standing task. Results Walking with the DAS-AFO resulted in an average 24% increase in ankle push-off power when compared to the solid AFO (p = .003). Both AFO conditions resulted in an average 16% reduction in soleus activity compared to shod (p < .040); only the DAS-AFO reduced vastus lateralis activity compared to shod (13% average reduction, p = .015). Over half of the participants preferred a different AFO stiffness for at least one of the tasks of daily living. No stiffness setting was universally preferred for a single task. During the stable standing task, the high stiffness setting increased average anterior–posterior center of pressure excursion (p = .022) and velocity (p = .001) compared to shod. Conclusion Our findings highlight potential benefits of the DAS-AFO design over solid AFOs, including improved ankle joint motions and push-off power during walking. Customizability of the DAS-AFO positively influenced participant preference and task performance.
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (2) , 1740-1747
A Quasi-Passive Robotic Ankle Foot Orthosis With Speed-Adaptive Stiffness
Ankle foot orthoses (AFOs) are one of the most prescribed mobility devices for individuals with walking disability from conditions like cerebral palsy (CP) and stroke. Current AFO designs offer a fixed stiffness during walking, functioning optimally at only a single speed. The primary goal of this study was to develop and validate a quasi-passive robotic AFO that automatically adjusted stiffness to a user's walking speed. We designed a leaf spring AFO with an adjustable pivot point actuated by a compact linear servo motor. We developed a walking speed estimator using onboard sensors to automatically adjust the pivot point location, and therefore device stiffness. First, we characterized stiffness range, adjustment response time, and battery life during walking. Next, we performed clinical device validation testing in five individuals with CP during stand-to-run acceleration bouts and at constant walking speeds. The AFO exhibited a stiffness range of 60 to 250 Nm/rad during normal walking and up to 300-400 Nm/rad under certain conditions (e.g., running) for the CP participants. The device was able to adjust stiffness by ∼200 Nm/rad during swing phase in ∼0.25 seconds. Battery life approached 6000 steps. The on-board controller accurately predicted relative changes in walking speed for the five participants with CP (R 2 = 0.92 ± 0.04), demonstrating the ability to automatically increase device stiffness with ambulation speed. This study advances the state-of-the-art for quasi-passive AFOs that can function optimally at different ambulation speeds.
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (2) , 1740-1747
A Quasi-Passive Robotic Ankle Foot Orthosis With Speed-Adaptive Stiffness
Ankle foot orthoses (AFOs) are one of the most prescribed mobility devices for individuals with walking disability from conditions like cerebral palsy (CP) and stroke. Current AFO designs offer a fixed stiffness during walking, functioning optimally at only a single speed. The primary goal of this study was to develop and validate a quasi-passive robotic AFO that automatically adjusted stiffness to a user's walking speed. We designed a leaf spring AFO with an adjustable pivot point actuated by a compact linear servo motor. We developed a walking speed estimator using onboard sensors to automatically adjust the pivot point location, and therefore device stiffness. First, we characterized stiffness range, adjustment response time, and battery life during walking. Next, we performed clinical device validation testing in five individuals with CP during stand-to-run acceleration bouts and at constant walking speeds. The AFO exhibited a stiffness range of 60 to 250 Nm/rad during normal walking and up to 300-400 Nm/rad under certain conditions (e.g., running) for the CP participants. The device was able to adjust stiffness by ∼200 Nm/rad during swing phase in ∼0.25 seconds. Battery life approached 6000 steps. The on-board controller accurately predicted relative changes in walking speed for the five participants with CP (R 2 = 0.92 ± 0.04), demonstrating the ability to automatically increase device stiffness with ambulation speed. This study advances the state-of-the-art for quasi-passive AFOs that can function optimally at different ambulation speeds.
- Open Access
- 2 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 497-506
Robustness Implies Privacy in Statistical Estimation
We study the relationship between adversarial robustness and differential privacy in high-dimensional algorithmic statistics. We give the first black-box reduction from privacy to robustness which can produce private estimators with optimal tradeoffs among sample complexity, accuracy, and privacy for a wide range of fundamental high-dimensional parameter estimation problems, including mean and covariance estimation. We show that this reduction can be implemented in polynomial time in some important special cases. In particular, using nearly-optimal polynomial-time robust estimators for the mean and covariance of high-dimensional Gaussians which are based on the Sum-of-Squares method, we design the first polynomial-time private estimators for these problems with nearly-optimal samples-accuracy-privacy tradeoffs. Our algorithms are also robust to a nearly optimal fraction of adversarially-corrupted samples.
- 2 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 497-506
Open AccessRobustness Implies Privacy in Statistical Estimation
We study the relationship between adversarial robustness and differential privacy in high-dimensional algorithmic statistics. We give the first black-box reduction from privacy to robustness which can produce private estimators with optimal tradeoffs among sample complexity, accuracy, and privacy for a wide range of fundamental high-dimensional parameter estimation problems, including mean and covariance estimation. We show that this reduction can be implemented in polynomial time in some important special cases. In particular, using nearly-optimal polynomial-time robust estimators for the mean and covariance of high-dimensional Gaussians which are based on the Sum-of-Squares method, we design the first polynomial-time private estimators for these problems with nearly-optimal samples-accuracy-privacy tradeoffs. Our algorithms are also robust to a nearly optimal fraction of adversarially-corrupted samples.
- 18 April 2019
- Published by Springer Nature
- p. 226-250
Sum-of-Squares Meets Program Obfuscation, Revisited
- 18 April 2019
- Published by Springer Nature
- p. 226-250
Sum-of-Squares Meets Program Obfuscation, Revisited