Mahmoud S. Mahmoud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahmoud S. Mahmoud has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Huynh Van Khang
University of Agder
5 shared publications - Kjell Gunnar Robbersmyr
University of Agder
4 shared publications - Ahmed Salem
Department of Engineering Sciences, University of Agder, Grimstad, Norway
2 shared publications - Duy-Hung Ha
Ton Duc Thang University
1 shared publication - Jagath Sri Lal Senanayaka
Department of Engineering Sciences, Universitetet i Agder - Campus Grimstad, 243285 Grimstad Norway 4879
1 shared publication - Mikal Laursen
Faculty of Engineering and Science, University of Agder, Grimstad, Norway
1 shared publication
Latest Publications
- Open Access
- 3 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 115217-115225
Robust Fault Classification in Permanent Magnet Synchronous Machines Under Dynamic and Noisy Conditions
Detection and isolation of multiple low-severity faults in permanent magnet synchronous machines (PMSMs) under dynamics and noisy conditions are very important to enhance the system’s reliability, lifetime, and service availability. This study investigates a robust fault classification scheme for PMSMs under low-severity, multiple-fault conditions in noisy and variable-speed scenarios. Two supervised learning models, namely Extra Trees (ET) and Support Vector Machine (SVM), are developed and compared using time-domain (TD) and frequency-domain (FD) features. A hybrid feature extraction method is adopted to balance the computational burden and classification accuracy. Hyperparameters and frequency-domain (FD) features are optimized based on prediction confidence, prediction times, and accuracy. Furthermore, the robustness of the data-driven models is evaluated at different Signal-to-Noise (SNR) ratios under mixed faults and variable speeds in an in-house PMSM, combining an inter-turn short circuit fault of 2.2% in one phase and a 30% demagnetization of one rotor magnet. A comparative study was conducted, confirming the proposed ET model’s superior performance in terms of prediction accuracy and robustness.
- 3 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 115217-115225
Open AccessRobust Fault Classification in Permanent Magnet Synchronous Machines Under Dynamic and Noisy Conditions
Detection and isolation of multiple low-severity faults in permanent magnet synchronous machines (PMSMs) under dynamics and noisy conditions are very important to enhance the system’s reliability, lifetime, and service availability. This study investigates a robust fault classification scheme for PMSMs under low-severity, multiple-fault conditions in noisy and variable-speed scenarios. Two supervised learning models, namely Extra Trees (ET) and Support Vector Machine (SVM), are developed and compared using time-domain (TD) and frequency-domain (FD) features. A hybrid feature extraction method is adopted to balance the computational burden and classification accuracy. Hyperparameters and frequency-domain (FD) features are optimized based on prediction confidence, prediction times, and accuracy. Furthermore, the robustness of the data-driven models is evaluated at different Signal-to-Noise (SNR) ratios under mixed faults and variable speeds in an in-house PMSM, combining an inter-turn short circuit fault of 2.2% in one phase and a 30% demagnetization of one rotor magnet. A comparative study was conducted, confirming the proposed ET model’s superior performance in terms of prediction accuracy and robustness.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 10250-10261
Robust Self-Augmented Open-Circuit Fault Diagnosis of Three-Level Inverters for EV Powertrains
With the rapid advancement of data collection systems, data-driven fault diagnosis approaches have significantly improved the detection of open-circuit (OC) faults in voltage source inverters (VSIs). However, the diverse operating conditions and noisy environments in electric vehicles (EVs) cause feature variations, rendering challenges in maintaining the high accuracy and robustness of existing methods. This article introduces a robust self-augmented deep learning (DL) method for detecting OC faults in VSIs working at various operation conditions. The proposed method automatically extracts the most relevant statistical features from the measured signals using an automatic feature extraction module (AFEM) based on an improved particle swarm optimization (PSO) algorithm. Then, these optimized features are utilized through an attention-based multi-input convolution neural network (A-MICNN) embedded with a multihead self-attention module (SAM) to effectively capture the local and global characteristics of different OC faults. The A-MICNN architecture effectively processes these multi-inputs by employing shared weights and feature extraction layers to fuse information from statistical features and time-frequency image data. The proposed method is validated using an in-house three-level (3L) F-type inverter setup, achieving a remarkable diagnosis accuracy of 99.74% with high robustness across various speeds, load conditions, and noise levels, providing an efficient solution for EV powertrain fault diagnosis.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 10250-10261
Robust Self-Augmented Open-Circuit Fault Diagnosis of Three-Level Inverters for EV Powertrains
With the rapid advancement of data collection systems, data-driven fault diagnosis approaches have significantly improved the detection of open-circuit (OC) faults in voltage source inverters (VSIs). However, the diverse operating conditions and noisy environments in electric vehicles (EVs) cause feature variations, rendering challenges in maintaining the high accuracy and robustness of existing methods. This article introduces a robust self-augmented deep learning (DL) method for detecting OC faults in VSIs working at various operation conditions. The proposed method automatically extracts the most relevant statistical features from the measured signals using an automatic feature extraction module (AFEM) based on an improved particle swarm optimization (PSO) algorithm. Then, these optimized features are utilized through an attention-based multi-input convolution neural network (A-MICNN) embedded with a multihead self-attention module (SAM) to effectively capture the local and global characteristics of different OC faults. The A-MICNN architecture effectively processes these multi-inputs by employing shared weights and feature extraction layers to fuse information from statistical features and time-frequency image data. The proposed method is validated using an in-house three-level (3L) F-type inverter setup, achieving a remarkable diagnosis accuracy of 99.74% with high robustness across various speeds, load conditions, and noise levels, providing an efficient solution for EV powertrain fault diagnosis.
- Open Access
- 11 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 1210-1223
A Few-Shot Open-Circuit Fault Diagnosis of F-Type Inverters Using CGAN-Based Vision Transformer
Multilevel inverters (MLIs) are widely adopted in various industries owing to their distinctive features. However, they are susceptible to higher failure rates due to the increased number of components. Deep learning (DL) models are widely used for accurately diagnosing faults in inverters because they effectively extract features automatically. These models work on the hypothesis of the availability of a sufficient number of samples to train the diagnostic models. However, obtaining enough sample data in engineering practice is difficult, especially in fault cases. Therefore, this article proposes a fault diagnosis scheme combining a conditional generative adversarial network (CGAN) and a vision transformer (ViT) for diagnosing open-circuit faults with few fault samples (few shots). Firstly, the measured signals are converted to time-frequency images. Afterwards, CGAN generates new 2-D sample images with data distributions similar to real samples. Finally, the improved ViT uses the original and generated samples to learn and extract local and global features with a multi-head self-attention mechanism and classify the faults. The proposed scheme is validated using an experimental setup of the F-type inverter, and the results show that the suggested scheme outperforms the other conventional DL methods with an accuracy of 98.46% using only six samples per class.
- 11 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 1210-1223
Open AccessA Few-Shot Open-Circuit Fault Diagnosis of F-Type Inverters Using CGAN-Based Vision Transformer
Multilevel inverters (MLIs) are widely adopted in various industries owing to their distinctive features. However, they are susceptible to higher failure rates due to the increased number of components. Deep learning (DL) models are widely used for accurately diagnosing faults in inverters because they effectively extract features automatically. These models work on the hypothesis of the availability of a sufficient number of samples to train the diagnostic models. However, obtaining enough sample data in engineering practice is difficult, especially in fault cases. Therefore, this article proposes a fault diagnosis scheme combining a conditional generative adversarial network (CGAN) and a vision transformer (ViT) for diagnosing open-circuit faults with few fault samples (few shots). Firstly, the measured signals are converted to time-frequency images. Afterwards, CGAN generates new 2-D sample images with data distributions similar to real samples. Finally, the improved ViT uses the original and generated samples to learn and extract local and global features with a multi-head self-attention mechanism and classify the faults. The proposed scheme is validated using an experimental setup of the F-type inverter, and the results show that the suggested scheme outperforms the other conventional DL methods with an accuracy of 98.46% using only six samples per class.
- Open Access
- 1 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Industrial Electronics Society
- Vol. 4, 762-772
Robust Multiple-Fault Diagnosis of PMSM Drives Under Variant Operations and Noisy Conditions
With the rapid development of industrial applications using permanent magnet synchronous motors (PMSMs) and the Internet of Things, the demand for using robust fault diagnosis methods working in noisy conditions has increased significantly. The current data-driven methods depend mainly on deep learning (DL) models due to the effectiveness of automated feature extraction. However, these models have shallow depths compared with benchmark convolution neural networks, limiting their accuracy in final predictions, and they are established based on the hypothesis that the measured data are noiseless. Despite this, electric machinery is subjected to various noise sources that interfere with measurements during operation. This article proposes a new scheme combining a transfer-learned pretrained residual neural network (ResNet) and supervised machine learning (S-ML) to enhance the performance of DL models in noisy industrial environments. The effectiveness of the proposed scheme is validated using an in-house setup of a PMSM drive with demagnetization and intern-short circuit faults at variant operating conditions. The results show that the proposed method significantly reduced the computational burden by tenfold on average while improving the average accuracy to 96.84% across all the datasets compared with other DL and S-ML methods, with high robustness in noisy working conditions.
- 1 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Industrial Electronics Society
- Vol. 4, 762-772
Open AccessRobust Multiple-Fault Diagnosis of PMSM Drives Under Variant Operations and Noisy Conditions
With the rapid development of industrial applications using permanent magnet synchronous motors (PMSMs) and the Internet of Things, the demand for using robust fault diagnosis methods working in noisy conditions has increased significantly. The current data-driven methods depend mainly on deep learning (DL) models due to the effectiveness of automated feature extraction. However, these models have shallow depths compared with benchmark convolution neural networks, limiting their accuracy in final predictions, and they are established based on the hypothesis that the measured data are noiseless. Despite this, electric machinery is subjected to various noise sources that interfere with measurements during operation. This article proposes a new scheme combining a transfer-learned pretrained residual neural network (ResNet) and supervised machine learning (S-ML) to enhance the performance of DL models in noisy industrial environments. The effectiveness of the proposed scheme is validated using an in-house setup of a PMSM drive with demagnetization and intern-short circuit faults at variant operating conditions. The results show that the proposed method significantly reduced the computational burden by tenfold on average while improving the average accuracy to 96.84% across all the datasets compared with other DL and S-ML methods, with high robustness in noisy working conditions.