Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Simon James Cox has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Low-Cost Sensor Network for Monitoring Peatland

    by Hazel Louise Mitchell, Simon J. Cox, Hugh G. Lewis

    Peatlands across the world are vital carbon stores. However, human activities have caused the degradation of many sites, increasing their greenhouse gas emissions and vulnerability to wildfires. Comprehensive monitoring of peatlands is essential for their protection, tracking degradation and restoration, but current techniques are limited by cost, poor reliability and low spatial or temporal resolution. This paper covers the research, development, deployment and performance of a resilient and modular multi-purpose wireless sensor network as an alternative means of monitoring peatlands. The sensor network consists of four sensor nodes and a gateway and measures temperature, humidity, soil moisture, carbon dioxide and methane. The sensor nodes transmit measured data over LoRaWAN to The Things Network every 30 min. To increase the maximum possible deployment duration, a novel datastring encoder was implemented which reduced the transmitted datastring length by 23%. This system was deployed in a New Forest (Hampshire, UK) peatland site for two months and collected more than 7500 measurements. This deployment demonstrated that low-cost sensor networks have the potential to improve the temporal and spatial resolution of peatland emission monitoring beyond what is achievable with traditional monitoring techniques.


  • Open Access

    Comparing Large-Eddy Simulation and Gaussian Plume Model to Sensor Measurements of an Urban Smoke Plume

    by Dominic Clements, Matthew Coburn, Simon J. Cox, Florentin M. J. Bulot, Zheng-Tong Xie, Christina Vanderwel

    The fast prediction of the extent and impact of accidental air pollution releases is important to enable a quick and informed response, especially in cities. Despite this importance, only a small number of case studies are available studying the dispersion of air pollutants from fires in a short distance (O(1 km)) in urban areas. While monitoring pollution levels in Southampton, UK, using low-cost sensors, a fire broke out from an outbuilding containing roughly 3000 reels of highly flammable cine nitrate film and movie equipment, which resulted in high values of PM2.5 being measured by the sensors approximately 1500 m downstream of the fire site. This provided a unique opportunity to evaluate urban air pollution dispersion models using observed data for PM2.5 and the meteorological conditions. Two numerical approaches were used to simulate the plume from the transient fire: a high-fidelity computational fluid dynamics model with large-eddy simulation (LES) embedded in the open-source package OpenFOAM, and a lower-fidelity Gaussian plume model implemented in a commercial software package: the Atmospheric Dispersion Modeling System (ADMS). Both numerical models were able to quantitatively reproduce consistent spatial and temporal profiles of the PM2.5 concentration at approximately 1500 m downstream of the fire site. Considering the unavoidable large uncertainties, a comparison between the sensor measurements and the numerical predictions was carried out, leading to an approximate estimation of the emission rate, temperature, and the start and duration of the fire. The estimation of the fire start time was consistent with the local authority report. The LES data showed that the fire lasted for at least 80 min at an emission rate of 50 g/s of PM2.5. The emission was significantly greater than a ‘normal’ house fire reported in the literature, suggesting the crucial importance of the emission estimation and monitoring of PM2.5 concentration in such incidents. Finally, we discuss the advantages and limitations of the two numerical approaches, aiming to suggest the selection of fast-response numerical models at various compromised levels of accuracy, efficiency and cost.


  • Open Access

    Calibration of a Low-Cost Methane Sensor Using Machine Learning

    by Hazel Louise Mitchell, Simon J. Cox, Hugh G. Lewis

    In order to combat greenhouse gas emissions, the sources of these emissions must be understood. Environmental monitoring using low-cost wireless devices is one method of measuring emissions in crucial but remote settings, such as peatlands. The Figaro NGM2611-E13 is a low-cost methane detection module based around the TGS2611-E00 sensor. The manufacturer provides sensitivity characteristics for methane concentrations above 300 ppm, but lower concentrations are typical in outdoor settings. This study investigates the potential to calibrate these sensors for lower methane concentrations using machine learning. Models of varying complexity, accounting for temperature and humidity variations, were trained on over 50,000 calibration datapoints, spanning 0–200 ppm methane, 5–30 °C and 40–80% relative humidity. Interaction terms were shown to improve model performance. The final selected model achieved a root-mean-square error of 5.1 ppm and an R2 of 0.997, demonstrating the potential for the NGM2611-E13 sensor to measure methane concentrations below 200 ppm.


  • Open Access

    Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution—Part B—Particle Number Concentrations

    by Florentin Michel Jacques Bulot, Hugo Savill Russell, Mohsen Rezaei, Matthew Stanley Johnson, Steven James Ossont, Andrew Kevin Richard Morris, Philip James Basford, Natasha Hazel Celeste Easton, Hazel Louise Mitchell, Gavin Lee Foster, et al.

    Low-cost Particulate Matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors, but some models of sensors also report Particle Number Concentrations (PNCs) segregated into different PM size ranges. In this study, eight units each of Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors’ to different particle size distributions to quantify and better understand the low-cost sensors performance across a range of relevant environmental ranges. The PNCs reported by the sensors were analysed to characterise sensor-reported particle size distribution, to determine whether sensor-reported PNCs can follow the transient variations of PM observed by the reference instruments and to determine the relative impact of different variables on the performances of the sensors. This study shows that the Alphasense OPC-R1 reported at least five size ranges independently from each other, that the Sensirion SPS30 reported two size ranges independently from each other and that all the size ranges reported by the Plantower PMS5003 were not independent of each other. It demonstrates that all sensors tested here could track the fine temporal variation of PNCs, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it shows that particle size distribution and composition are more impactful on sensor measurements than relative humidity.


  • Open Access

    Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution - Part B - Particle Number Concentrations

    by Florentin Michel Jacques Bulot, Hugo Savill Russell, Mohsen Rezaei, Matthew Stanley Johnson, Steven James Ossont, Andrew Kevin Richard Morris, Philip James Basford, Natasha Hazel Celeste Easton, Hazel Louise Mitchell, Gavin Lee Foster, et al.

    Low-cost particulate matter (PM) sensors offer an excellent opportunity to improve our knowledge about this type of pollution. Their size and their cost, which support multi-node network deployment, along with their temporal resolution, enable them to report fine spatio-temporal resolution for a given area. These sensors have known issues across performance metrics. Generally, the literature focuses on the PM mass concentration reported by these sensors but some models of sensors also report particle number concentrations (PNC) segregated into different PM size bins. In this study, 8 units of each Alphasense OPC-R1, Plantower PMS5003 and Sensirion SPS30 have been exposed, under controlled conditions, to short-lived peaks of PM generated using two different combustion sources of PM, exposing the sensors to different particle size distributions to quantify and better understand the low cost sensors performance across a range of relevant environmental ranges. The PNC reported by the sensors were analysed. This study showed that there is added value in directly using the PNC reported by the sensors instead of the mass concentrations, which could aid the efforts to calibrate these sensors to a known accuracy. It demonstrated that all sensors tested here could track the fine temporal variation of PNC, that the Alphasense OPC-R1 could closely follow the variations of size distribution between the two sources of PM, and it showed that particle size distribution and composition are more impactful on the sensors measurement than relative humidity.


  • Open Access

    An Assessment of the Performance of the Secure Remote Update Protocol in Simulated Real-World Conditions

    by Andrew John Poulter, Simon J. Cox

    This paper assesses the relative performance of the MQTT protocol in comparison to the Secure Remote Update Protocol (SRUP) in a number of simulated real-world conditions, and describes an experiment that has been conducted to measure the processing delay associated with the use of the more secure protocol. Experimental measurements for power consumption of the devices and the size of comparable TCP packets were also made. Analysis shows that the use of the SRUP protocol added an additional processing delay of between 42.92 ms and 51.60 ms—depending on the specific hardware in use. There was also shown to be a 55.47% increase in power consumption when running the secure SRUP protocol, compared with an MQTT implementation.


  • Open Access

    Enabling Secure Guest Access for Command-and-Control of Internet of Things Devices

    by Andrew John Poulter, Simon J. Cox

    Internet of Things (IoT) devices are becoming ubiquitous, and may be arranged to form formal or ad hoc Command and Control (C2) networks. Such networks typically do not have a mechanism to facilitate the sharing of either data or control inputs. This paper examines this problem in the context of IoT devices operating within C2 systems which do not have a trusted relationship with each other. We propose a solution which we call syndication, to provide a controlled mechanism to share data between C2 systems of devices without a fully trusted relationship. This paper builds upon previous work which established a lightweight protocol for secure C2 operations within the IoT. Using the proposed approach enables not only sharing of data but also permits the external controller to submit moderated requests for actions to be performed. The paper concludes by examining how this approach could also be adopted to provide secure guest access to connected systems in a domestic or commercial context.


  • Open Access

    Enabling the Secure Use of Dynamic Identity for the Internet of Things—Using the Secure Remote Update Protocol (SRUP)

    by Andrew John Poulter, Steven J. Ossont, Simon J. Cox

    This paper examines dynamic identity, as it pertains to the Internet of Things (IoT), and explores the practical implementation of a mitigation technique for some of the key weaknesses of a conventional dynamic identity model. This paper explores human-centric and machine-based observer approaches for confirming device identity, permitting automated identity confirmation for deployed systems. It also assesses the advantages of dynamic identity in the context of identity revocation permitting secure change of ownership for IoT devices. The paper explores use-cases for human and machine-based observation for authentication of device identity when devices join a Command and Control(C2) network, and considers the relative merits for these two approaches for different types of system.


  • Open Access

    Enabling the secure use of Dynamic Identity for the Internet of Things — using the Secure Remote Update Protocol (SRUP)

    by Andrew John Poulter, Steven J. Ossont, Simon J. Cox

    This paper examines dynamic identity, as it pertains to the IoT; and explores the practical implementation of a mitigation to some of the key weaknesses of a conventional dynamic identity model. This paper explores human-centric and machine-based observer approaches for confirming device identity, permitting automated identity confirmation for deployed systems. It also assesses the advantages of dynamic identity in the context of identity revocation permitting secure change of ownership for IoT devices. The paper explores use-cases for human and machine-based observation for authentication of device identity when devices join a C2 network, and considers the relative merits for these two approaches for different types of system.


  • Open Access

    Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution

    by Florentin Michel Jacques Bulot, Hugo Savill Russell, Mohsen Rezaei, Matthew Stanley Johnson, Steven James Johnston Ossont, Andrew Kevin Richard Morris, Philip James Basford, Natasha Hazel Celeste Easton, Gavin Lee Foster, Matthew Loxham, et al.

    Airborne particulate matter (PM) exposure has been identified as a key environmental risk factor, associated especially with diseases of the respiratory and cardiovascular system and with almost 9 million premature deaths per year. Low-cost optical sensors for PM measurement are desirable for monitoring exposure closer to the personal level and particularly suited for developing spatiotemporally dense city sensor networks. However, questions remain over the accuracy and reliability of the data they produce, particularly regarding the influence of environmental parameters such as humidity and temperature, and with varying PM sources and concentration profiles. In this study, eight units each of five different models of commercially available low-cost optical PM sensors (40 individual sensors in total) were tested under controlled laboratory conditions, against higher-grade instruments for: lower limit of detection, response time, responses to sharp pollution spikes lasting <1 min , and the impact of differing humidity and PM source. All sensors detected the spikes generated with a varied range of performances depending on the model and presenting different sensitivity mainly to sources of pollution and to size distributions with a lesser impact of humidity. The sensitivity to particle size distribution indicates that the sensors may provide additional information to PM mass concentrations. It is concluded that improved performance in field monitoring campaigns, including tracking sources of pollution, could be achieved by using a combination of some of the different models to take advantage of the additional information made available by their differential response.