Aytrik Bose
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aytrik Bose has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jayanta K. Chandra
Electrical Engineering department, Government College of Engineering Textile Technology, Berhampur, West Bengal, India
2 shared publications - Rajarshi Gupta
Department of Applied Physics, University of Calcutta, Kolkata, India
2 shared publications - Arunansu Talukdar
Medical College and Hospital Kolkata, Kolkata, India
1 shared publication - Dipankar Ghosh
Department of ECE, Future Institute of Engineering and Management, Kolkata, India
1 shared publication - Shatanik Mukherjee
Department of ECE, Future Institute of Engineering and Management, Kolkata, India
1 shared publication - Soujanya Chowdhury
Department of Electrical Engineering, Ramkrishna Mahato Government Engineering College, Narayanpur 723103, India
1 shared publication
Latest Publications
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
PPG-Derived Respiration Signal Predictor-Guided Simple Rule-Based Detection of COPD
Chronic obstructive pulmonary disease (COPD) is one of the common respiratory diseases that can cause death if not intervened in time. Popular lung sound sensing-based COPD detection techniques mostly employ deep learning techniques, which suffer from the disadvantages of purely data-driven models, like low robustness against data variability across diversified datasets. This article introduces a finger photoplethysmography (PPG)-based COPD detection technique using a low-complexity, simple rule-based classifier. The primary feature extraction was done using dynamic mode decomposition (DMD), which requires low memory. A novel respiration signal predictor (RSP) based on bidirectional reservoir computing (B-RC) model is proposed to identify respiration indicative DMD mode. Evaluation was done with a total of 4970 PPG frames, each of size 2750 samples collected from three public datasets and volunteers, resulting in 95.13% accuracy and 100% sensitivity of the RSP. Detection accuracy and sensitivity of acute COPD, moderate COPD, healthy subjects, and artificially obstructed breathing (AOB) class (a synthetic one derived from healthy subjects) were 99.7% and 99.5%, respectively. The average latency and peak memory requirement on single-core ARM v6 controller (512-MB RAM and 1-GHz frequency) were 616 ms and 458.44 kB, respectively, to process one PPG frame. The present method can be utilized for quick screening of COPD as a point-of-care (POC) technology.
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
PPG-Derived Respiration Signal Predictor-Guided Simple Rule-Based Detection of COPD
Chronic obstructive pulmonary disease (COPD) is one of the common respiratory diseases that can cause death if not intervened in time. Popular lung sound sensing-based COPD detection techniques mostly employ deep learning techniques, which suffer from the disadvantages of purely data-driven models, like low robustness against data variability across diversified datasets. This article introduces a finger photoplethysmography (PPG)-based COPD detection technique using a low-complexity, simple rule-based classifier. The primary feature extraction was done using dynamic mode decomposition (DMD), which requires low memory. A novel respiration signal predictor (RSP) based on bidirectional reservoir computing (B-RC) model is proposed to identify respiration indicative DMD mode. Evaluation was done with a total of 4970 PPG frames, each of size 2750 samples collected from three public datasets and volunteers, resulting in 95.13% accuracy and 100% sensitivity of the RSP. Detection accuracy and sensitivity of acute COPD, moderate COPD, healthy subjects, and artificially obstructed breathing (AOB) class (a synthetic one derived from healthy subjects) were 99.7% and 99.5%, respectively. The average latency and peak memory requirement on single-core ARM v6 controller (512-MB RAM and 1-GHz frequency) were 616 ms and 458.44 kB, respectively, to process one PPG frame. The present method can be utilized for quick screening of COPD as a point-of-care (POC) technology.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
On-Device Signal Quality Guided and Embedded Physiologic Information for High Fidelity Continuous PPG Compression
Photoplethysmography (PPG) is widely popularized in wearable gadgets for continuous health monitoring. The main challenge before the PPG-based measurements is motion artifact (MA) corruption, which often suppress vital physiological information like heart rate (HR) and respiratory rate (RR), which makes their extraction difficult and sometime erroneous. This work introduces a new approach of PPG multiclass signal quality assessment (SQA) using reservoir computing (RC) and tunable ${Q}$ -factor wavelet transform (TQWT) for PPG compression. To ensure the post compression clinical usage, HR and RR are embedded in the compressed bit stream, at every 10 s PPG frame. For the evaluation, a total of 200 records were utilized from three public datasets, namely, MIMIC II/III waveform, PPG RR benchmark (PRRB), BIDMC, and 20 volunteers at our laboratory, spanning a total duration of 7740 min. The technique showed good on-device (ARM v6 controller) performance on SQA (accuracy of 99.97%) and PPG compression (CR of 38.28 and percentage root mean squared difference (PRD) of 3.04 at 125 Hz sampling) using MIMIC data, which are competitive with published works. The low end-to-end latency (51 ms) and run time memory (19.99 kB) per 1 s PPG shows the usefulness for real-time deployment. It was also showed that embedding the physiologic information in compressed data may reduce the post compression processing error in RR and HR by an amount of 5.61% and 31.23% respectively in corrupted PPG. The proposed technique can be utilized in high fidelity PPG monitoring applications under ambulatory measurement.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
On-Device Signal Quality Guided and Embedded Physiologic Information for High Fidelity Continuous PPG Compression
Photoplethysmography (PPG) is widely popularized in wearable gadgets for continuous health monitoring. The main challenge before the PPG-based measurements is motion artifact (MA) corruption, which often suppress vital physiological information like heart rate (HR) and respiratory rate (RR), which makes their extraction difficult and sometime erroneous. This work introduces a new approach of PPG multiclass signal quality assessment (SQA) using reservoir computing (RC) and tunable ${Q}$ -factor wavelet transform (TQWT) for PPG compression. To ensure the post compression clinical usage, HR and RR are embedded in the compressed bit stream, at every 10 s PPG frame. For the evaluation, a total of 200 records were utilized from three public datasets, namely, MIMIC II/III waveform, PPG RR benchmark (PRRB), BIDMC, and 20 volunteers at our laboratory, spanning a total duration of 7740 min. The technique showed good on-device (ARM v6 controller) performance on SQA (accuracy of 99.97%) and PPG compression (CR of 38.28 and percentage root mean squared difference (PRD) of 3.04 at 125 Hz sampling) using MIMIC data, which are competitive with published works. The low end-to-end latency (51 ms) and run time memory (19.99 kB) per 1 s PPG shows the usefulness for real-time deployment. It was also showed that embedding the physiologic information in compressed data may reduce the post compression processing error in RR and HR by an amount of 5.61% and 31.23% respectively in corrupted PPG. The proposed technique can be utilized in high fidelity PPG monitoring applications under ambulatory measurement.