Shigang Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shigang Tian has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jian Wang
North China Electric Power University
7 shared publications - Heyao Huang
North China Electric Power University
5 shared publications Jiesha Chen
North China Electric Power University
5 shared publications- Jiayu Zhu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications - Fengyi Guo
College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China
2 shared publications - Hongxin Gao
Liaoning Technical University
2 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (6) , 3011-3021
Research on Metal Particle Morphology Identification in GIS Based on Optical Sensing and Multi-Task Learning
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (6) , 3011-3021
Research on Metal Particle Morphology Identification in GIS Based on Optical Sensing and Multi-Task Learning
- Open Access
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
A Study on High-Sensitivity Ultrasonic Sensing of GIS Partial Discharge Based on Flexible PVDF Film
To address the limitations of traditional piezoelectric ceramic (PZT) sensors in ultrasonic partial discharge (PD) detection for gas-insulated switchgear (GIS)—including narrow bandwidth, severe resonant ringing, and poor adaptability to curved enclosures—this paper develops a broadband ultrasonic sensor based on flexible polyvinylidene fluoride (PVDF) film.During the design stage, a simplified finite element model for the propagation and attenuation of PD-induced ultrasonic signals under typical GIS defects was established to provide a theoretical reference for the collaborative optimization of electrode topology and geometric dimensions. Experimental results show that the developed PVDF sensor achieves an average sensitivity of 60.18 dB (ref. 1 V/(m/s)) within the 20 kHz - 80 kHz frequency range, with a uniform frequency response characterized by a maximum deviation of less than ±3.08 dB. Comparative tests on a full-scale 126 kV GIS platform demonstrate that the sensor significantly suppresses the inherent resonant ringing of PZT sensors and substantially shortens the signal decay time, thereby enabling a more accurate recording of the transient envelope features of discharge pulses.Furthermore, the PVDF sensor exhibits strong high-frequency capture capability while maintaining effective reception of low-frequency signals, picking up rich acoustic information in the 45 kHz - 75 kHz band. As a flexible sensor with excellent curvature adaptability, it demonstrates robust signal-to-noise ratio (SNR) performance compared to traditional PZT sensors, specifically achieving a 36.8% SNR improvement in metal protrusion discharge detection. This study effectively eliminates hardware-induced waveform distortion and provides a high-fidelity data foundation for the online monitoring and refined defect diagnosis of GIS equipment.
- 26 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Open AccessA Study on High-Sensitivity Ultrasonic Sensing of GIS Partial Discharge Based on Flexible PVDF Film
To address the limitations of traditional piezoelectric ceramic (PZT) sensors in ultrasonic partial discharge (PD) detection for gas-insulated switchgear (GIS)—including narrow bandwidth, severe resonant ringing, and poor adaptability to curved enclosures—this paper develops a broadband ultrasonic sensor based on flexible polyvinylidene fluoride (PVDF) film.During the design stage, a simplified finite element model for the propagation and attenuation of PD-induced ultrasonic signals under typical GIS defects was established to provide a theoretical reference for the collaborative optimization of electrode topology and geometric dimensions. Experimental results show that the developed PVDF sensor achieves an average sensitivity of 60.18 dB (ref. 1 V/(m/s)) within the 20 kHz - 80 kHz frequency range, with a uniform frequency response characterized by a maximum deviation of less than ±3.08 dB. Comparative tests on a full-scale 126 kV GIS platform demonstrate that the sensor significantly suppresses the inherent resonant ringing of PZT sensors and substantially shortens the signal decay time, thereby enabling a more accurate recording of the transient envelope features of discharge pulses.Furthermore, the PVDF sensor exhibits strong high-frequency capture capability while maintaining effective reception of low-frequency signals, picking up rich acoustic information in the 45 kHz - 75 kHz band. As a flexible sensor with excellent curvature adaptability, it demonstrates robust signal-to-noise ratio (SNR) performance compared to traditional PZT sensors, specifically achieving a 36.8% SNR improvement in metal protrusion discharge detection. This study effectively eliminates hardware-induced waveform distortion and provides a high-fidelity data foundation for the online monitoring and refined defect diagnosis of GIS equipment.
- 12 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
GIS Surface Discharge and Metal Particle Size Identification Based on Silicon Photomultiplier and Lightweight CNN
Metal particles in gas-insulated switchgear (GIS) may attach to the insulator surface and cause surface discharge (SD), which can lead to flashover failure and threaten the stable operation of power grid. To develop an efficient method for SD detection and risk assessment, an optical pulse measurement module based on silicon photomultiplier is designed, and SD experiments of metal particles with different sizes are carried out on the basin insulator of a real 126 kV GIS device. By analyzing the SD inception voltage, time-domain and phase characteristics of optical pulses, a novel method for SD and particle size identification is proposed by combining phase resolved optical pulse pattern and lightweight convolutional neural network. Test and comparison experiments demonstrate that the proposed method exhibits superior generalization and real-time performance. The identification accuracy of SD sample by this method is 100%, and the identification accuracy of particle size is 98.52%. The average runtime of the proposed lightweight identification model in the embedded device is 173.96 ms. Finally, various interpretability techniques are combined to analyze the inference mechanism of the identification model and the feature importance of the optical pulse phase pattern samples.
- 12 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
GIS Surface Discharge and Metal Particle Size Identification Based on Silicon Photomultiplier and Lightweight CNN
Metal particles in gas-insulated switchgear (GIS) may attach to the insulator surface and cause surface discharge (SD), which can lead to flashover failure and threaten the stable operation of power grid. To develop an efficient method for SD detection and risk assessment, an optical pulse measurement module based on silicon photomultiplier is designed, and SD experiments of metal particles with different sizes are carried out on the basin insulator of a real 126 kV GIS device. By analyzing the SD inception voltage, time-domain and phase characteristics of optical pulses, a novel method for SD and particle size identification is proposed by combining phase resolved optical pulse pattern and lightweight convolutional neural network. Test and comparison experiments demonstrate that the proposed method exhibits superior generalization and real-time performance. The identification accuracy of SD sample by this method is 100%, and the identification accuracy of particle size is 98.52%. The average runtime of the proposed lightweight identification model in the embedded device is 173.96 ms. Finally, various interpretability techniques are combined to analyze the inference mechanism of the identification model and the feature importance of the optical pulse phase pattern samples.
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-15
Efficient Detection of Series Arc Fault at the Back End of Frequency Converter Using KTDM-Optimized Lightweight Model
Series arc fault (SAF) is one of the main causes of electrical fire. There is no effective detection method for SAF at the back end of frequency converter (BEFC). A lightweight SAF identification model was proposed and an on-line SAF detection device was developed. First, the SAF experiments at the BEFC were carried out. Second, the SAF identification model was designed based on EfficientNet, multiple lightweight modules MBConv were applied to extract the SAF features, and the global average pooling layer was used to improve the model’s complexity. Third, a lightweight design method KTDM, which was proposed based on the idea of reducing feature mapping redundancy, was used to optimize the identification model. The specific steps include: a) visualize the feature mappings output from the convolutional layers of the model by using t-SNE algorithm; 2) cluster the visualization results by using k-means++ algorithm; 3) analyze the clustering results by using elbow method and silhouette coefficient, and determine the optimal channel number of the convolutional layers. Finally, the optimized model was deployed to an embedded device to detect SAF under various operation conditions in real time. Both identification accuracy and real-time performance meet IEC62606 standard. KTDM can improve the complexity and real-time performance of the model without obviously lowering its identification accuracy and robustness.
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-15
Efficient Detection of Series Arc Fault at the Back End of Frequency Converter Using KTDM-Optimized Lightweight Model
Series arc fault (SAF) is one of the main causes of electrical fire. There is no effective detection method for SAF at the back end of frequency converter (BEFC). A lightweight SAF identification model was proposed and an on-line SAF detection device was developed. First, the SAF experiments at the BEFC were carried out. Second, the SAF identification model was designed based on EfficientNet, multiple lightweight modules MBConv were applied to extract the SAF features, and the global average pooling layer was used to improve the model’s complexity. Third, a lightweight design method KTDM, which was proposed based on the idea of reducing feature mapping redundancy, was used to optimize the identification model. The specific steps include: a) visualize the feature mappings output from the convolutional layers of the model by using t-SNE algorithm; 2) cluster the visualization results by using k-means++ algorithm; 3) analyze the clustering results by using elbow method and silhouette coefficient, and determine the optimal channel number of the convolutional layers. Finally, the optimized model was deployed to an embedded device to detect SAF under various operation conditions in real time. Both identification accuracy and real-time performance meet IEC62606 standard. KTDM can improve the complexity and real-time performance of the model without obviously lowering its identification accuracy and robustness.
- Open Access
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 5851-5863
Series Arc Fault Identification Method Based on Lightweight Convolutional Neural Network
The fast and accurate series arc fault (SAF) identification method and its hardware implementation are the key to the development of arc fault circuit interrupter (AFCI) or arc fault detection device (AFDD). The SAF experiments under household multi-branch circuit conditions were conducted. And a novel SAF identification model based on lightweight one-dimensional (1-D) convolutional neural network was proposed. First, the main-circuit current signal was used as the input of the model. The 1-D convolutional layers and 1-D maximum pooling layers of the model were used to extract the features of the current signal. The fully connected neural network (FCNN) was used to identify whether or not there is a SAF in the circuit and determine the branch-circuit where the fault is located. Second, the second to fourth standard convolutional layers of the model were improved by using depthwise separable convolution, and the batch normalization layers were added to the model, so as to realize the optimal design of the model. Finally, the model was deployed to an embedded device and its performance was tested. When the sampling frequency is higher than 5 kHz, the accuracy of fault identification and fault line selection of the model in the embedded device is higher than 98.05% and 99.11%, respectively. The average runtime of single identification is 5.26 ms. It meets the technical requirements of household AFCI or AFDD.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 5851-5863
Open AccessSeries Arc Fault Identification Method Based on Lightweight Convolutional Neural Network
The fast and accurate series arc fault (SAF) identification method and its hardware implementation are the key to the development of arc fault circuit interrupter (AFCI) or arc fault detection device (AFDD). The SAF experiments under household multi-branch circuit conditions were conducted. And a novel SAF identification model based on lightweight one-dimensional (1-D) convolutional neural network was proposed. First, the main-circuit current signal was used as the input of the model. The 1-D convolutional layers and 1-D maximum pooling layers of the model were used to extract the features of the current signal. The fully connected neural network (FCNN) was used to identify whether or not there is a SAF in the circuit and determine the branch-circuit where the fault is located. Second, the second to fourth standard convolutional layers of the model were improved by using depthwise separable convolution, and the batch normalization layers were added to the model, so as to realize the optimal design of the model. Finally, the model was deployed to an embedded device and its performance was tested. When the sampling frequency is higher than 5 kHz, the accuracy of fault identification and fault line selection of the model in the embedded device is higher than 98.05% and 99.11%, respectively. The average runtime of single identification is 5.26 ms. It meets the technical requirements of household AFCI or AFDD.