Nan Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nan Zheng has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Yurong Li
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
5 shared publications Jian-Ning Sun
Nanjing Drum Tower Hospital Group Suqian Hospital
2 shared publicationsMiao-Qin Zhan
Fuzhou University
2 shared publicationsCai-Bin Dong
Fuzhou University
1 shared publication- Deqing Hu
Department of Sports Medicine, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, PR China.
1 shared publication - Han Li
Fuzhou University
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 4239-4248
Neuromuscular Adaptations in Degenerative Rotator Cuff Tears: Contributions of Aging and Pathology
Degenerative rotator cuff tear (RCT) is associated with impaired shoulder function; however, the extent to which altered neuromuscular coordination reflects aging-related changes or pathology-associated alterations remains unclear. This study aimed to characterize shoulder neuromuscular coordination patterns associated with aging and degenerative RCT using a multidimensional electromyographic approach. Surface electromyography was recorded from eight shoulder-related muscles during maximal shoulder abduction and flexion tasks in 106 participants, including young controls (YC, n=24), elderly controls (EC, n=24), and patients with degenerative RCT (n=58). Muscle synergy characteristics were quantified using non-negative matrix factorization (NMF). Intermuscular coordination was assessed using beta-band coherence analysis, and muscle interaction patterns were further evaluated using network topology metrics. Compared with YC participants, both EC and RCT groups demonstrated reduced muscle synergy dimensionality, with no significant differences between EC and RCT groups. Synergy structure analyses revealed task-dependent differences among groups, and RCT participants exhibited coordination patterns partially similar to those observed in elderly controls. Intermuscular coherence and network analyses demonstrated group-specific alterations mainly during shoulder abduction, involving deltoid-related and deltoid-scapular muscle interactions. These findings suggest that degenerative RCT is associated with altered muscle coordination patterns superimposed on age-related neuromuscular changes. This study provides a comprehensive characterization of age- and pathology-associated alterations in shoulder neuromuscular coordination. The integration of muscle synergy, coherence, and network analyses may provide quantitative insights into functional impairment mechanisms in degenerative RCT and support future development of individualized rehabilitation strategies.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 4239-4248
Open AccessNeuromuscular Adaptations in Degenerative Rotator Cuff Tears: Contributions of Aging and Pathology
Degenerative rotator cuff tear (RCT) is associated with impaired shoulder function; however, the extent to which altered neuromuscular coordination reflects aging-related changes or pathology-associated alterations remains unclear. This study aimed to characterize shoulder neuromuscular coordination patterns associated with aging and degenerative RCT using a multidimensional electromyographic approach. Surface electromyography was recorded from eight shoulder-related muscles during maximal shoulder abduction and flexion tasks in 106 participants, including young controls (YC, n=24), elderly controls (EC, n=24), and patients with degenerative RCT (n=58). Muscle synergy characteristics were quantified using non-negative matrix factorization (NMF). Intermuscular coordination was assessed using beta-band coherence analysis, and muscle interaction patterns were further evaluated using network topology metrics. Compared with YC participants, both EC and RCT groups demonstrated reduced muscle synergy dimensionality, with no significant differences between EC and RCT groups. Synergy structure analyses revealed task-dependent differences among groups, and RCT participants exhibited coordination patterns partially similar to those observed in elderly controls. Intermuscular coherence and network analyses demonstrated group-specific alterations mainly during shoulder abduction, involving deltoid-related and deltoid-scapular muscle interactions. These findings suggest that degenerative RCT is associated with altered muscle coordination patterns superimposed on age-related neuromuscular changes. This study provides a comprehensive characterization of age- and pathology-associated alterations in shoulder neuromuscular coordination. The integration of muscle synergy, coherence, and network analyses may provide quantitative insights into functional impairment mechanisms in degenerative RCT and support future development of individualized rehabilitation strategies.
- Open Access
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. PP (15344320) , 1
The Changes in Synergistic Patterns of Peri-shoulder Muscles during Shoulder Abduction and Flexion in Patients with Rotator Cuff Tears
Understanding muscle synergy variability and its clinical relevance in rotator cuff tear (RCT) patients is crucial for elucidating motor control mechanisms and informing rehabilitation. This study uses non-negative matrix factorization (NMF) to assess the influence of age and pathological factors on synergy patterns during abduction (ABD) and flexion (FL) tasks. Fifteen young controls (YC), fifteen elderly controls (EC), and twenty elderly RCT patients were recruited. Surface electromyography (sEMG) signals from eight shoulder muscles were recorded for NMF analysis, and the correlation with the Constant-Murley Score (CMS) was evaluated via regression. Results revealed that the number of synergies in the FL task was significantly lower in the RCT group compared to the EC (4.5 ± 1.3 vs. 5.6 ± 1.1, P = 0.01) and YC groups (4.5 ± 1.3 vs. 5.6 ± 1.0, P = 0.03), with no significant difference in the ABD task (P = 0.10). In ABD, synergy pattern 1 was dominated by the upper trapezius and middle trapezius, while in the EC group, pattern 4 was driven by the supraspinatus, and in the YC group, both supraspinatus and posterior deltoid were involved. In FL, the middle deltoid weight was significantly increased in pattern 3 in the RCT group, suggesting compensatory activation or a pathological marker. The root mean square value of middle deltoid strongly correlated with CMS (ABD: R² = 0.53, P < 0.001; FL: R² = 0.46, P < 0.001). These findings reveal task-specific compensation mechanisms in RCT patients and provide insights for targeted rehabilitation strategies.
- 5 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. PP (15344320) , 1
Open AccessThe Changes in Synergistic Patterns of Peri-shoulder Muscles during Shoulder Abduction and Flexion in Patients with Rotator Cuff Tears
Understanding muscle synergy variability and its clinical relevance in rotator cuff tear (RCT) patients is crucial for elucidating motor control mechanisms and informing rehabilitation. This study uses non-negative matrix factorization (NMF) to assess the influence of age and pathological factors on synergy patterns during abduction (ABD) and flexion (FL) tasks. Fifteen young controls (YC), fifteen elderly controls (EC), and twenty elderly RCT patients were recruited. Surface electromyography (sEMG) signals from eight shoulder muscles were recorded for NMF analysis, and the correlation with the Constant-Murley Score (CMS) was evaluated via regression. Results revealed that the number of synergies in the FL task was significantly lower in the RCT group compared to the EC (4.5 ± 1.3 vs. 5.6 ± 1.1, P = 0.01) and YC groups (4.5 ± 1.3 vs. 5.6 ± 1.0, P = 0.03), with no significant difference in the ABD task (P = 0.10). In ABD, synergy pattern 1 was dominated by the upper trapezius and middle trapezius, while in the EC group, pattern 4 was driven by the supraspinatus, and in the YC group, both supraspinatus and posterior deltoid were involved. In FL, the middle deltoid weight was significantly increased in pattern 3 in the RCT group, suggesting compensatory activation or a pathological marker. The root mean square value of middle deltoid strongly correlated with CMS (ABD: R² = 0.53, P < 0.001; FL: R² = 0.46, P < 0.001). These findings reveal task-specific compensation mechanisms in RCT patients and provide insights for targeted rehabilitation strategies.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (9) , 6551-6564
DenoiseMamba: An Innovative Approach for EEG Artifact Removal Leveraging Mamba and CNN
Electroencephalography (EEG) is a widely used tool for monitoring brain activity, but it is often disturbed by various artifacts, such as electrooculography (EOG), electromyography (EMG), and electrocardiography (ECG), which degrade signal quality and affect subsequent analysis. Effective EEG denoising is critical for enhancing the performance of EEG-based applications, including disease diagnosis and brain-computer interfaces (BCIs). While recent deep learning (DL) approaches have shown promise in this area, they often struggle to efficiently model the temporal dependencies inherent in EEG signals, as well as to capture local contextual information simultaneously. In this work, we introduce DenoiseMamba, a novel deep learning-based EEG denoising model. The model incorporates the ConvSSD module, which integrates convolutional neural networks (CNNs) with structured state-space duality (SSD) mechanisms. This allows DenoiseMamba to capture both local and global spatiotemporal features, resulting in more effective artifact suppression. Extensive experiments on three semi-simulated datasets demonstrate that DenoiseMamba outperforms existing methods in EEG reconstruction accuracy, effectively eliminating myoelectric, electrooculographic, and electrocardiographic artifacts while preserving critical EEG signal details.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (9) , 6551-6564
DenoiseMamba: An Innovative Approach for EEG Artifact Removal Leveraging Mamba and CNN
Electroencephalography (EEG) is a widely used tool for monitoring brain activity, but it is often disturbed by various artifacts, such as electrooculography (EOG), electromyography (EMG), and electrocardiography (ECG), which degrade signal quality and affect subsequent analysis. Effective EEG denoising is critical for enhancing the performance of EEG-based applications, including disease diagnosis and brain-computer interfaces (BCIs). While recent deep learning (DL) approaches have shown promise in this area, they often struggle to efficiently model the temporal dependencies inherent in EEG signals, as well as to capture local contextual information simultaneously. In this work, we introduce DenoiseMamba, a novel deep learning-based EEG denoising model. The model incorporates the ConvSSD module, which integrates convolutional neural networks (CNNs) with structured state-space duality (SSD) mechanisms. This allows DenoiseMamba to capture both local and global spatiotemporal features, resulting in more effective artifact suppression. Extensive experiments on three semi-simulated datasets demonstrate that DenoiseMamba outperforms existing methods in EEG reconstruction accuracy, effectively eliminating myoelectric, electrooculographic, and electrocardiographic artifacts while preserving critical EEG signal details.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Natural Control of Muscle Strength Training Instrument Based on EMG-Driven Multistep Ahead Models
Traditional muscle strength training instruments often rely on torque-based feedback to guide exercises, which can introduce delays in system response and result in discomfort due to hysteresis effects. To overcome the lag in torque-based muscle strength training instruments, surface electromyography (sEMG) signals were used as control inputs. The sEMG is generated 20-80ms before movement, which is called muscle electromechanical delay. If the torque can be effectively predicted during this period, the lag effect can be significantly reduced, thus improving the effectiveness and comfort of training. Therefore, we proposed a multi-step ahead (MSA) model based on the nonlinear autoregressive network with exogenous inputs (NARX) dynamic recurrent neural network. It predicted torques using sEMG, allowed natural control of the instrument. The results showed that normalized root mean square error (NRMSE) was lower than 0.1167, and the Pearson correlation coefficients (ρ) exceeded 0.9444, even when the ahead steps achieved 35. The intra-subject and the inter-subject validation demonstrated significantly lower NRMSE (p < 0.05) and higher ρ (p < 0.05) of the MSA model, compared with some state-of-the-art recursive models and typical models without autoregression items. It proves that the MSA can accurately predict the motion. Meanwhile, the introduction of the sEMG signal as a control source significantly reduced the root mean square jerk (RMSJ) of the torque, demonstrating smoother motion. The experimental results revealed that the one-step-ahead model achieved an average response time of 3.73 ms, which is markedly lower than the muscle electromechanical delay. And the response time increased by an average of approximately 0.068 ms per additional ahead step. In conclusion, the proposed EMG-driven muscle strength training instrument enables natural muscle strength training.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Natural Control of Muscle Strength Training Instrument Based on EMG-Driven Multistep Ahead Models
Traditional muscle strength training instruments often rely on torque-based feedback to guide exercises, which can introduce delays in system response and result in discomfort due to hysteresis effects. To overcome the lag in torque-based muscle strength training instruments, surface electromyography (sEMG) signals were used as control inputs. The sEMG is generated 20-80ms before movement, which is called muscle electromechanical delay. If the torque can be effectively predicted during this period, the lag effect can be significantly reduced, thus improving the effectiveness and comfort of training. Therefore, we proposed a multi-step ahead (MSA) model based on the nonlinear autoregressive network with exogenous inputs (NARX) dynamic recurrent neural network. It predicted torques using sEMG, allowed natural control of the instrument. The results showed that normalized root mean square error (NRMSE) was lower than 0.1167, and the Pearson correlation coefficients (ρ) exceeded 0.9444, even when the ahead steps achieved 35. The intra-subject and the inter-subject validation demonstrated significantly lower NRMSE (p < 0.05) and higher ρ (p < 0.05) of the MSA model, compared with some state-of-the-art recursive models and typical models without autoregression items. It proves that the MSA can accurately predict the motion. Meanwhile, the introduction of the sEMG signal as a control source significantly reduced the root mean square jerk (RMSJ) of the torque, demonstrating smoother motion. The experimental results revealed that the one-step-ahead model achieved an average response time of 3.73 ms, which is markedly lower than the muscle electromechanical delay. And the response time increased by an average of approximately 0.068 ms per additional ahead step. In conclusion, the proposed EMG-driven muscle strength training instrument enables natural muscle strength training.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Recognition of Muscular Activity in Complex Noise-Contaminated Myoelectric Signals: An Adaptive Two-Step Approach
Surface electromyography (sEMG) signals demonstrate how the muscles react to the control strategies of the nervous system. For stroke patients, the detection of muscle activation is crucial because it allows researchers to better understand their brain control mechanisms. However, extracting the muscular activity precisely from the sEMG signals with various complex noises is a challenge in biomedical data processing. This study presented an adaptive two-step muscular activity recognition algorithm to handle this problem. The sEMG signal was first pre-extracted using the adaptive threshold approach and annexation method to identify the interval comprising active information. Then, after amplifying the difference of activity and inactivity of the interval signal through the Teager-Kaiser Energy operator, the onsets and offsets were determined based on the overall change of the interval signal. The proposed algorithm was tested in semi-synthetic signals, real signals from a public database, and experimentally recorded signals. Compared with other approaches, our method can effectively handle various types of interference and produce the best detection performance. Additionally, the steps of parameter selection and adjustment are removed, which greatly simplifies the practical application.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Recognition of Muscular Activity in Complex Noise-Contaminated Myoelectric Signals: An Adaptive Two-Step Approach
Surface electromyography (sEMG) signals demonstrate how the muscles react to the control strategies of the nervous system. For stroke patients, the detection of muscle activation is crucial because it allows researchers to better understand their brain control mechanisms. However, extracting the muscular activity precisely from the sEMG signals with various complex noises is a challenge in biomedical data processing. This study presented an adaptive two-step muscular activity recognition algorithm to handle this problem. The sEMG signal was first pre-extracted using the adaptive threshold approach and annexation method to identify the interval comprising active information. Then, after amplifying the difference of activity and inactivity of the interval signal through the Teager-Kaiser Energy operator, the onsets and offsets were determined based on the overall change of the interval signal. The proposed algorithm was tested in semi-synthetic signals, real signals from a public database, and experimentally recorded signals. Compared with other approaches, our method can effectively handle various types of interference and produce the best detection performance. Additionally, the steps of parameter selection and adjustment are removed, which greatly simplifies the practical application.