Zhenyao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenyao Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Deqiang Gan
Zhejiang University
3 shared publications Deqiang Gan
2 shared publications- Jing Li
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications - Hao Wu
Zhejiang Key Laboratory of Electrical Technology and System on Renewable Energy College of Electrical Engineering Zhejiang University Hangzhou China
1 shared publication Jing Li
College of Electrical Engineering Zhejiang University Hangzhou China
1 shared publicationQian Zhang
1 shared publication
Latest Publications
- Open Access
- 6 October 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
On the input-output monotonicity of voltage dynamics of power systems with grid-forming converters
- 6 October 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Open AccessOn the input-output monotonicity of voltage dynamics of power systems with grid-forming converters
- Open Access
- 5 August 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (16) , 2732-2745
An analytical approach for power system frequency stability evaluation
Recent years have seen high penetration of renewable energies, which have significantly reduced the inertia of bulk power systems. As a result, the frequency behaviour of power systems is becoming more complex. To resolve this technical challenge, there is a particularly strong interest in developing analytical solutions for frequency dynamics studies. This study first describes a second‐order frequency dynamics model for power systems with renewable energies. A non‐linear perturbation approach is suggested to drive the analytical solution of the model. It is shown that, under many circumstances, frequency dynamics can be effectively approximated using a linear model. Subsequently, the article describes a fourth‐order linear frequency dynamics model that takes into account governor‐turbines. A polynomial eigenvalue method is proposed to identify the dominant and non‐dominant modes of the solution of the four‐order model. It is demonstrated that the dominant mode has a decisive impact on frequency behaviour, while the non‐dominant modes influence the relative frequency oscillations only. Finally, the study derives the analytical expressions of the standard frequency performance metrics and examines the impact of damping and inertia parameters. The introduced results are verified using two test systems, demonstrating the accuracy and effectiveness of the suggested method.
- 5 August 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (16) , 2732-2745
Open AccessAn analytical approach for power system frequency stability evaluation
Recent years have seen high penetration of renewable energies, which have significantly reduced the inertia of bulk power systems. As a result, the frequency behaviour of power systems is becoming more complex. To resolve this technical challenge, there is a particularly strong interest in developing analytical solutions for frequency dynamics studies. This study first describes a second‐order frequency dynamics model for power systems with renewable energies. A non‐linear perturbation approach is suggested to drive the analytical solution of the model. It is shown that, under many circumstances, frequency dynamics can be effectively approximated using a linear model. Subsequently, the article describes a fourth‐order linear frequency dynamics model that takes into account governor‐turbines. A polynomial eigenvalue method is proposed to identify the dominant and non‐dominant modes of the solution of the four‐order model. It is demonstrated that the dominant mode has a decisive impact on frequency behaviour, while the non‐dominant modes influence the relative frequency oscillations only. Finally, the study derives the analytical expressions of the standard frequency performance metrics and examines the impact of damping and inertia parameters. The introduced results are verified using two test systems, demonstrating the accuracy and effectiveness of the suggested method.
- Open Access
- 19 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 33816-33831
Harmonic Solution of Higher-Dimensional Second Order Kuramoto Oscillator Network
Obtaining the solution of Kuramoto oscillator model is an effective way to understand the mechanism behind the dynamical behaviors it represents. However, it is not an easy work to get, even the approximation solution for the second order Kuramoto oscillator network because of its complex coupling interaction and strong nonlinearity. Hence, this paper first establishes a new polynomial mathematical model for the second order Kuramoto oscillator network, which is partly decoupled in a polynomial fashion. Then, a quadratic harmonic balance method (HBM) is developed to get the approximate solution for quadratic differential algebraic equation (QDAE) system. An equivalent quadratic technique is introduced to convert the polynomial Kuramoto oscillator model into a QDAE system aiming to obtain its harmonic solution. Finally, the suggested harmonic solution is utilized to explain the morphological characteristics of the stable motion of oscillators, and the relative motions for the oscillators in Kuramoto network is concluded by a set of nonlinear state output equations. It is also found that the distance between the maximum phase angle and the controlling unstable equilibrium point (UEP) can be used as a stability margin for the oscillator network. A single-machine infinite bus (SMIB) power system, an IEEE 3-machine 9-bus power system and an IEEE 10-machine 39-bus power system are employed as different dimension second order Kuramoto oscillator network cases to demonstrate the validation and accuracy of the proposed method and analysis.
- 19 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 33816-33831
Open AccessHarmonic Solution of Higher-Dimensional Second Order Kuramoto Oscillator Network
Obtaining the solution of Kuramoto oscillator model is an effective way to understand the mechanism behind the dynamical behaviors it represents. However, it is not an easy work to get, even the approximation solution for the second order Kuramoto oscillator network because of its complex coupling interaction and strong nonlinearity. Hence, this paper first establishes a new polynomial mathematical model for the second order Kuramoto oscillator network, which is partly decoupled in a polynomial fashion. Then, a quadratic harmonic balance method (HBM) is developed to get the approximate solution for quadratic differential algebraic equation (QDAE) system. An equivalent quadratic technique is introduced to convert the polynomial Kuramoto oscillator model into a QDAE system aiming to obtain its harmonic solution. Finally, the suggested harmonic solution is utilized to explain the morphological characteristics of the stable motion of oscillators, and the relative motions for the oscillators in Kuramoto network is concluded by a set of nonlinear state output equations. It is also found that the distance between the maximum phase angle and the controlling unstable equilibrium point (UEP) can be used as a stability margin for the oscillator network. A single-machine infinite bus (SMIB) power system, an IEEE 3-machine 9-bus power system and an IEEE 10-machine 39-bus power system are employed as different dimension second order Kuramoto oscillator network cases to demonstrate the validation and accuracy of the proposed method and analysis.
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (2) , 1151-1161
Stability Analysis of PLL-Type Grid-Connected Converter Based on The Perturbation Method
In recent years, the widespread adoption of phase-locked loop type grid-connected converters has presented new challenges for transient stability and small-signal stability analysis of power systems. Therefore, it is crucial to develop effective methods for analyzing the stability of converters-interfaced power systems. In this paper, a generalized swing equation model of a single converter connected to an infinite bus is derived. Then, approximate analytical solutions for the model are obtained. The accuracy of the analytical solutions is verified through simulation analysis. Based on the analytical solution, a parameter stability analysis is performed to gain further insights on both transient and small-signal stability. Finally, the proposed results are verified using several examples, demonstrating the accuracy and effectiveness of the suggested methods.
- 10 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (2) , 1151-1161
Stability Analysis of PLL-Type Grid-Connected Converter Based on The Perturbation Method
In recent years, the widespread adoption of phase-locked loop type grid-connected converters has presented new challenges for transient stability and small-signal stability analysis of power systems. Therefore, it is crucial to develop effective methods for analyzing the stability of converters-interfaced power systems. In this paper, a generalized swing equation model of a single converter connected to an infinite bus is derived. Then, approximate analytical solutions for the model are obtained. The accuracy of the analytical solutions is verified through simulation analysis. Based on the analytical solution, a parameter stability analysis is performed to gain further insights on both transient and small-signal stability. Finally, the proposed results are verified using several examples, demonstrating the accuracy and effectiveness of the suggested methods.