Han Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Han Liu has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Yubo Fan
Vanderbilt University
10 shared publicationsBenoit M. Dawant
Vanderbilt University
9 shared publicationsIpek Oguz
Vanderbilt University
9 shared publicationsZhoubing Xu
Siemens Healthineers
6 shared publicationsCan Cui
Vanderbilt University
4 shared publicationsDewei Hu
Vanderbilt University
4 shared publications
Latest Publications
- Open Access
- 1 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (02) , 1-12
Influence of early through late fusion on pancreas segmentation from imperfectly registered multimodal magnetic resonance imaging
PurposeCombining different types of medical imaging data, through multimodal fusion, promises better segmentation of anatomical structures, such as the pancreas. Strategic implementation of multimodal fusion could improve our ability to study diseases such as diabetes. However, where to perform fusion in deep learning models is still an open question. It is unclear if there is a single best location to fuse information when analyzing pairs of imperfectly aligned images or if the optimal fusion location depends on the specific model being used. Two main challenges when using multiple imaging modalities to study the pancreas are (1) the pancreas and surrounding abdominal anatomy have a deformable structure, making it difficult to consistently align the images and (2) breathing by the individual during image collection further complicates the alignment between multimodal images. Even after using state-of-the-art deformable image registration techniques, specifically designed to align abdominal images, multimodal images of the abdomen are often not perfectly aligned. We examine how the choice of different fusion points, ranging from early in the image processing pipeline to later stages, impacts the segmentation of the pancreas on imperfectly registered multimodal magnetic resonance (MR) images.ApproachOur dataset consists of 353 pairs of T2-weighted (T2w) and T1-weighted (T1w) abdominal MR images from 163 subjects with accompanying pancreas segmentation labels drawn mainly based on the T2w images. Because the T2w images were acquired in an interleaved manner across two breath holds and the T1w images on one breath hold, there were three different breath holds impacting the alignment of each pair of images. We used deeds, a state-of-the-art deformable abdominal image registration method to align the image pairs. Then, we trained a collection of basic UNets with different fusion points, spanning from early to late layers in the model, to assess how early through late fusion influenced segmentation performance on imperfectly aligned images. To investigate whether performance differences on key fusion points are generalized to other architectures, we expanded our experiments to nnUNet.ResultsThe single-modality T2w baseline using a basic UNet model had a median Dice score of 0.766, whereas the same baseline on the nnUNet model achieved 0.824. For each fusion approach, we analyzed the differences in performance with Dice residuals, by subtracting the baseline score from the fusion score for each datapoint. For the basic UNet, the best fusion approach was from early/mid fusion and occurred in the middle of the encoder with a median Dice residual of +0.012 compared with the baseline. For the nnUNet, the best fusion approach was early fusion through naïve image concatenation before the model, with a median Dice residual of +0.004 compared with the baseline. After Bonferroni correction, the distributions of the Dice scores for these best fusion approaches were found to be statistically significant (p<0.05) via the paired Wilcoxon signed-rank test against the baseline.ConclusionsFusion in specific blocks can improve performance, but the best blocks for fusion are model-specific, and the gains are small. In imperfectly registered datasets, fusion is a nuanced problem, with the art of design remaining vital for uncovering potential insights. Future innovation is needed to better address fusion in cases of imperfect alignment of abdominal image pairs. The code associated with this project is available here https://github.com/MASILab/influence_of_fusion_on_pancreas_segmentation.
- 1 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (02) , 1-12
Open AccessInfluence of early through late fusion on pancreas segmentation from imperfectly registered multimodal magnetic resonance imaging
PurposeCombining different types of medical imaging data, through multimodal fusion, promises better segmentation of anatomical structures, such as the pancreas. Strategic implementation of multimodal fusion could improve our ability to study diseases such as diabetes. However, where to perform fusion in deep learning models is still an open question. It is unclear if there is a single best location to fuse information when analyzing pairs of imperfectly aligned images or if the optimal fusion location depends on the specific model being used. Two main challenges when using multiple imaging modalities to study the pancreas are (1) the pancreas and surrounding abdominal anatomy have a deformable structure, making it difficult to consistently align the images and (2) breathing by the individual during image collection further complicates the alignment between multimodal images. Even after using state-of-the-art deformable image registration techniques, specifically designed to align abdominal images, multimodal images of the abdomen are often not perfectly aligned. We examine how the choice of different fusion points, ranging from early in the image processing pipeline to later stages, impacts the segmentation of the pancreas on imperfectly registered multimodal magnetic resonance (MR) images.ApproachOur dataset consists of 353 pairs of T2-weighted (T2w) and T1-weighted (T1w) abdominal MR images from 163 subjects with accompanying pancreas segmentation labels drawn mainly based on the T2w images. Because the T2w images were acquired in an interleaved manner across two breath holds and the T1w images on one breath hold, there were three different breath holds impacting the alignment of each pair of images. We used deeds, a state-of-the-art deformable abdominal image registration method to align the image pairs. Then, we trained a collection of basic UNets with different fusion points, spanning from early to late layers in the model, to assess how early through late fusion influenced segmentation performance on imperfectly aligned images. To investigate whether performance differences on key fusion points are generalized to other architectures, we expanded our experiments to nnUNet.ResultsThe single-modality T2w baseline using a basic UNet model had a median Dice score of 0.766, whereas the same baseline on the nnUNet model achieved 0.824. For each fusion approach, we analyzed the differences in performance with Dice residuals, by subtracting the baseline score from the fusion score for each datapoint. For the basic UNet, the best fusion approach was from early/mid fusion and occurred in the middle of the encoder with a median Dice residual of +0.012 compared with the baseline. For the nnUNet, the best fusion approach was early fusion through naïve image concatenation before the model, with a median Dice residual of +0.004 compared with the baseline. After Bonferroni correction, the distributions of the Dice scores for these best fusion approaches were found to be statistically significant (p<0.05) via the paired Wilcoxon signed-rank test against the baseline.ConclusionsFusion in specific blocks can improve performance, but the best blocks for fusion are model-specific, and the gains are small. In imperfectly registered datasets, fusion is a nuanced problem, with the art of design remaining vital for uncovering potential insights. Future innovation is needed to better address fusion in cases of imperfect alignment of abdominal image pairs. The code associated with this project is available here https://github.com/MASILab/influence_of_fusion_on_pancreas_segmentation.
- 28 December 2024
- Published by Springer Nature
- p. 372-385
Learning Site-Specific Styles for Multi-institutional Unsupervised Cross-Modality Domain Adaptation
- 28 December 2024
- Published by Springer Nature
- p. 372-385
Learning Site-Specific Styles for Multi-institutional Unsupervised Cross-Modality Domain Adaptation
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (5) , e230521
Deep Learning–based Unsupervised Domain Adaptation via a Unified Model for Prostate Lesion Detection Using Multisite Biparametric MRI Datasets
To determine whether the unsupervised domain adaptation (UDA) method with generated images improves the performance of a supervised learning (SL) model for prostate cancer (PCa) detection using multisite biparametric (bp) MRI datasets. This retrospective study included data from 5150 patients (14 191 samples) collected across nine different imaging centers. A novel UDA method using a unified generative model was developed for PCa detection using multisite bpMRI datasets. This method translates diffusion-weighted imaging (DWI) acquisitions, including apparent diffusion coefficient (ADC) and individual diffusion-weighted (DW) images acquired using various b values, to align with the style of images acquired using b values recommended by Prostate Imaging Reporting and Data System (PI-RADS) guidelines. The generated ADC and DW images replace the original images for PCa detection. An independent set of 1692 test cases (2393 samples) was used for evaluation. The area under the receiver operating characteristic curve (AUC) was used as the primary metric, and statistical analysis was performed via bootstrapping. For all test cases, the AUC values for baseline SL and UDA methods were 0.73 and 0.79 (P < .001), respectively, for PCa lesions with PI-RADS score of 3 or greater and 0.77 and 0.80 (P < .001) for lesions with PI-RADS scores of 4 or greater. In the 361 test cases under the most unfavorable image acquisition setting, the AUC values for baseline SL and UDA were 0.49 and 0.76 (P < .001) for lesions with PI-RADS scores of 3 or greater and 0.50 and 0.77 (P < .001) for lesions with PI-RADS scores of 4 or greater. UDA with generated images improved the performance of SL methods in PCa lesion detection across multisite datasets with various b values, especially for images acquired with significant deviations from the PI-RADS-recommended DWI protocol (eg, with an extremely high b value). Keywords: Prostate Cancer Detection, Multisite, Unsupervised Domain Adaptation, Diffusion-weighted Imaging, b Value Supplemental material is available for this article. © RSNA, 2024
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (5) , e230521
Deep Learning–based Unsupervised Domain Adaptation via a Unified Model for Prostate Lesion Detection Using Multisite Biparametric MRI Datasets
To determine whether the unsupervised domain adaptation (UDA) method with generated images improves the performance of a supervised learning (SL) model for prostate cancer (PCa) detection using multisite biparametric (bp) MRI datasets. This retrospective study included data from 5150 patients (14 191 samples) collected across nine different imaging centers. A novel UDA method using a unified generative model was developed for PCa detection using multisite bpMRI datasets. This method translates diffusion-weighted imaging (DWI) acquisitions, including apparent diffusion coefficient (ADC) and individual diffusion-weighted (DW) images acquired using various b values, to align with the style of images acquired using b values recommended by Prostate Imaging Reporting and Data System (PI-RADS) guidelines. The generated ADC and DW images replace the original images for PCa detection. An independent set of 1692 test cases (2393 samples) was used for evaluation. The area under the receiver operating characteristic curve (AUC) was used as the primary metric, and statistical analysis was performed via bootstrapping. For all test cases, the AUC values for baseline SL and UDA methods were 0.73 and 0.79 (P < .001), respectively, for PCa lesions with PI-RADS score of 3 or greater and 0.77 and 0.80 (P < .001) for lesions with PI-RADS scores of 4 or greater. In the 361 test cases under the most unfavorable image acquisition setting, the AUC values for baseline SL and UDA were 0.49 and 0.76 (P < .001) for lesions with PI-RADS scores of 3 or greater and 0.50 and 0.77 (P < .001) for lesions with PI-RADS scores of 4 or greater. UDA with generated images improved the performance of SL methods in PCa lesion detection across multisite datasets with various b values, especially for images acquired with significant deviations from the PI-RADS-recommended DWI protocol (eg, with an extremely high b value). Keywords: Prostate Cancer Detection, Multisite, Unsupervised Domain Adaptation, Diffusion-weighted Imaging, b Value Supplemental material is available for this article. © RSNA, 2024
- 6 April 2024
- Published by Elsevier in Medical Image Analysis
- Vol. 95, 103164
Domain generalization for retinal vessel segmentation via Hessian-based vector field
- 6 April 2024
- Published by Elsevier in Medical Image Analysis
- Vol. 95, 103164
Domain generalization for retinal vessel segmentation via Hessian-based vector field
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (5) , 1995-2009
COSST: Multi-Organ Segmentation With Partially Labeled Datasets Using Comprehensive Supervisions and Self-Training
Deep learning models have demonstrated remarkable success in multi-organ segmentation but typically require large-scale datasets with all organs of interest annotated. However, medical image datasets are often low in sample size and only partially labeled, i.e., only a subset of organs are annotated. Therefore, it is crucial to investigate how to learn a unified model on the available partially labeled datasets to leverage their synergistic potential. In this paper, we systematically investigate the partial-label segmentation problem with theoretical and empirical analyses on the prior techniques. We revisit the problem from a perspective of partial label supervision signals and identify two signals derived from ground truth and one from pseudo labels. We propose a novel two-stage framework termed COSST, which effectively and efficiently integrates comprehensive supervision signals with self-training. Concretely, we first train an initial unified model using two ground truth-based signals and then iteratively incorporate the pseudo label signal to the initial model using self-training. To mitigate performance degradation caused by unreliable pseudo labels, we assess the reliability of pseudo labels via outlier detection in latent space and exclude the most unreliable pseudo labels from each self-training iteration. Extensive experiments are conducted on one public and three private partial-label segmentation tasks over 12 CT datasets. Experimental results show that our proposed COSST achieves significant improvement over the baseline method, i.e., individual networks trained on each partially labeled dataset. Compared to the state-of-the-art partial-label segmentation methods, COSST demonstrates consistent superior performance on various segmentation tasks and with different training data sizes.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (5) , 1995-2009
COSST: Multi-Organ Segmentation With Partially Labeled Datasets Using Comprehensive Supervisions and Self-Training
Deep learning models have demonstrated remarkable success in multi-organ segmentation but typically require large-scale datasets with all organs of interest annotated. However, medical image datasets are often low in sample size and only partially labeled, i.e., only a subset of organs are annotated. Therefore, it is crucial to investigate how to learn a unified model on the available partially labeled datasets to leverage their synergistic potential. In this paper, we systematically investigate the partial-label segmentation problem with theoretical and empirical analyses on the prior techniques. We revisit the problem from a perspective of partial label supervision signals and identify two signals derived from ground truth and one from pseudo labels. We propose a novel two-stage framework termed COSST, which effectively and efficiently integrates comprehensive supervision signals with self-training. Concretely, we first train an initial unified model using two ground truth-based signals and then iteratively incorporate the pseudo label signal to the initial model using self-training. To mitigate performance degradation caused by unreliable pseudo labels, we assess the reliability of pseudo labels via outlier detection in latent space and exclude the most unreliable pseudo labels from each self-training iteration. Extensive experiments are conducted on one public and three private partial-label segmentation tasks over 12 CT datasets. Experimental results show that our proposed COSST achieves significant improvement over the baseline method, i.e., individual networks trained on each partially labeled dataset. Compared to the state-of-the-art partial-label segmentation methods, COSST demonstrates consistent superior performance on various segmentation tasks and with different training data sizes.
- Open Access
Learning Site-specific Styles for Multi-institutional Unsupervised Cross-modality Domain Adaptation
Unsupervised cross-modality domain adaptation is a challenging task in medical image analysis, and it becomes more challenging when source and target domain data are collected from multiple institutions. In this paper, we present our solution to tackle the multi-institutional unsupervised domain adaptation for the crossMoDA 2023 challenge. First, we perform unpaired image translation to translate the source domain images to the target domain, where we design a dynamic network to generate synthetic target domain images with controllable, site-specific styles. Afterwards, we train a segmentation model using the synthetic images and further reduce the domain gap by self-training. Our solution achieved the 1st place during both the validation and testing phases of the challenge. The code repository is publicly available at https://github.com/MedICL-VU/crossmoda2023.
Open AccessLearning Site-specific Styles for Multi-institutional Unsupervised Cross-modality Domain Adaptation
Unsupervised cross-modality domain adaptation is a challenging task in medical image analysis, and it becomes more challenging when source and target domain data are collected from multiple institutions. In this paper, we present our solution to tackle the multi-institutional unsupervised domain adaptation for the crossMoDA 2023 challenge. First, we perform unpaired image translation to translate the source domain images to the target domain, where we design a dynamic network to generate synthetic target domain images with controllable, site-specific styles. Afterwards, we train a segmentation model using the synthetic images and further reduce the domain gap by self-training. Our solution achieved the 1st place during both the validation and testing phases of the challenge. The code repository is publicly available at https://github.com/MedICL-VU/crossmoda2023.
- Open Access
COSST: Multi-organ Segmentation with Partially Labeled Datasets Using Comprehensive Supervisions and Self-training
Deep learning models have demonstrated remarkable success in multi-organ segmentation but typically require large-scale datasets with all organs of interest annotated. However, medical image datasets are often low in sample size and only partially labeled, i.e., only a subset of organs are annotated. Therefore, it is crucial to investigate how to learn a unified model on the available partially labeled datasets to leverage their synergistic potential. In this paper, we systematically investigate the partial-label segmentation problem with theoretical and empirical analyses on the prior techniques. We revisit the problem from a perspective of partial label supervision signals and identify two signals derived from ground truth and one from pseudo labels. We propose a novel two-stage framework termed COSST, which effectively and efficiently integrates comprehensive supervision signals with self-training. Concretely, we first train an initial unified model using two ground truth-based signals and then iteratively incorporate the pseudo label signal to the initial model using self-training. To mitigate performance degradation caused by unreliable pseudo labels, we assess the reliability of pseudo labels via outlier detection in latent space and exclude the most unreliable pseudo labels from each self-training iteration. Extensive experiments are conducted on one public and three private partial-label segmentation tasks over 12 CT datasets. Experimental results show that our proposed COSST achieves significant improvement over the baseline method, i.e., individual networks trained on each partially labeled dataset. Compared to the state-of-the-art partial-label segmentation methods, COSST demonstrates consistent superior performance on various segmentation tasks and with different training data sizes.
Open AccessCOSST: Multi-organ Segmentation with Partially Labeled Datasets Using Comprehensive Supervisions and Self-training
Deep learning models have demonstrated remarkable success in multi-organ segmentation but typically require large-scale datasets with all organs of interest annotated. However, medical image datasets are often low in sample size and only partially labeled, i.e., only a subset of organs are annotated. Therefore, it is crucial to investigate how to learn a unified model on the available partially labeled datasets to leverage their synergistic potential. In this paper, we systematically investigate the partial-label segmentation problem with theoretical and empirical analyses on the prior techniques. We revisit the problem from a perspective of partial label supervision signals and identify two signals derived from ground truth and one from pseudo labels. We propose a novel two-stage framework termed COSST, which effectively and efficiently integrates comprehensive supervision signals with self-training. Concretely, we first train an initial unified model using two ground truth-based signals and then iteratively incorporate the pseudo label signal to the initial model using self-training. To mitigate performance degradation caused by unreliable pseudo labels, we assess the reliability of pseudo labels via outlier detection in latent space and exclude the most unreliable pseudo labels from each self-training iteration. Extensive experiments are conducted on one public and three private partial-label segmentation tasks over 12 CT datasets. Experimental results show that our proposed COSST achieves significant improvement over the baseline method, i.e., individual networks trained on each partially labeled dataset. Compared to the state-of-the-art partial-label segmentation methods, COSST demonstrates consistent superior performance on various segmentation tasks and with different training data sizes.
- Open Access
- 31 October 2023
- Published by Springer Nature
- p. C1
Correction to: COLosSAL: A Benchmark for Cold-Start Active Learning for 3D Medical Image Segmentation
- 31 October 2023
- Published by Springer Nature
- p. C1
Open AccessCorrection to: COLosSAL: A Benchmark for Cold-Start Active Learning for 3D Medical Image Segmentation
- 1 October 2023
- Published by Springer Nature
- p. 25-34
COLosSAL: A Benchmark for Cold-Start Active Learning for 3D Medical Image Segmentation
- 1 October 2023
- Published by Springer Nature
- p. 25-34
COLosSAL: A Benchmark for Cold-Start Active Learning for 3D Medical Image Segmentation
- 1 September 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (05) , 055001-16
Evaluation of synthetically generated computed tomography for use in transcranial focused ultrasound procedures
PurposeTranscranial focused ultrasound (tFUS) is a therapeutic ultrasound method that focuses sound through the skull to a small region noninvasively and often under magnetic resonance imaging (MRI) guidance. CT imaging is used to estimate the acoustic properties that vary between individual skulls to enable effective focusing during tFUS procedures, exposing patients to potentially harmful radiation. A method to estimate acoustic parameters in the skull without the need for CT is desirable.ApproachWe synthesized CT images from routinely acquired T1-weighted MRI using a 3D patch-based conditional generative adversarial network and evaluated the performance of synthesized CT (sCT) images for treatment planning with tFUS. We compared the performance of sCT with real CT (rCT) images for tFUS planning using Kranion and simulations using the acoustic toolbox, k-Wave. Simulations were performed for 3 tFUS scenarios: (1) no aberration correction, (2) correction with phases calculated from Kranion, and (3) phase shifts calculated from time reversal.ResultsFrom Kranion, the skull density ratio, skull thickness, and number of active elements between rCT and sCT had Pearson’s correlation coefficients of 0.94, 0.92, and 0.98, respectively. Among 20 targets, differences in simulated peak pressure between rCT and sCT were largest without phase correction (12.4 % ± 8.1 % ) and smallest with Kranion phases (7.3 % ± 6.0 % ). The distance between peak focal locations between rCT and sCT was <1.3 mm for all simulation cases.ConclusionsReal and synthetically generated skulls had comparable image similarity, skull measurements, and acoustic simulation metrics. Our work demonstrated similar results for 10 testing cases comparing MR-sCTs and rCTs for tFUS planning. Source code and a docker image with the trained model are available at https://github.com/han-liu/SynCT_TcMRgFUS.
- 1 September 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (05) , 055001-16
Evaluation of synthetically generated computed tomography for use in transcranial focused ultrasound procedures
PurposeTranscranial focused ultrasound (tFUS) is a therapeutic ultrasound method that focuses sound through the skull to a small region noninvasively and often under magnetic resonance imaging (MRI) guidance. CT imaging is used to estimate the acoustic properties that vary between individual skulls to enable effective focusing during tFUS procedures, exposing patients to potentially harmful radiation. A method to estimate acoustic parameters in the skull without the need for CT is desirable.ApproachWe synthesized CT images from routinely acquired T1-weighted MRI using a 3D patch-based conditional generative adversarial network and evaluated the performance of synthesized CT (sCT) images for treatment planning with tFUS. We compared the performance of sCT with real CT (rCT) images for tFUS planning using Kranion and simulations using the acoustic toolbox, k-Wave. Simulations were performed for 3 tFUS scenarios: (1) no aberration correction, (2) correction with phases calculated from Kranion, and (3) phase shifts calculated from time reversal.ResultsFrom Kranion, the skull density ratio, skull thickness, and number of active elements between rCT and sCT had Pearson’s correlation coefficients of 0.94, 0.92, and 0.98, respectively. Among 20 targets, differences in simulated peak pressure between rCT and sCT were largest without phase correction (12.4 % ± 8.1 % ) and smallest with Kranion phases (7.3 % ± 6.0 % ). The distance between peak focal locations between rCT and sCT was <1.3 mm for all simulation cases.ConclusionsReal and synthetically generated skulls had comparable image similarity, skull measurements, and acoustic simulation metrics. Our work demonstrated similar results for 10 testing cases comparing MR-sCTs and rCTs for tFUS planning. Source code and a docker image with the trained model are available at https://github.com/han-liu/SynCT_TcMRgFUS.