Sizhe Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sizhe Xiang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Shoulong Dong
Chongqing University
10 shared publications - Chenguo Yao
School of Electrical Engineering, Chongqing University 1 , Chongqing 400044
7 shared publications - Lisheng Zhao
Chongqing University
7 shared publications - Liang Yu
College of Materials Science and Engineering, Chongqing University, Chongqing, China
5 shared publications Chenguo Yao
Chongqing University
3 shared publications- Qinyu Huang
State Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing, China
3 shared publications
Latest Publications
- Top Cited Papers
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (6) , 1277-1284
A Design and Analysis of RCD Oscillation Suppression Circuit for Marx Pulse Generator
Marx circuit is widely used in pulse-generating devices. However, in practical applications, the discharge loop of the Marx often includes stray capacitance and inductance, which can cause oscillations at the leading edge of the pulse. This article proposes an resistor-capacitor-diode (RCD) snubber circuit connected to the load in parallel to suppress waveform oscillations. First, the design of the RCD snubber circuit for the Marx pulse generator is presented, including the derivation of the equivalent circuit and characteristic equations. Next, the root locus method is applied to the analyzed parameters of the snubber circuit, determining the appropriate ranges of capacitance and resistance values for the RCD. Additionally, PSPICE simulation software is employed to verify the pulse oscillation suppression effectiveness of the RCD snubber circuit. Finally, the performance of the proposed RCD snubber circuit is tested on a Marx generator with 4 kV output voltage, 1 Hz frequency, and 500 ns pulsewidth. The test results demonstrate that the RCD snubber circuit has a great effect of oscillation suppression, which decreases the pules overshoot from 685 to 207 V, achieving a 69.8% reduction.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (6) , 1277-1284
Top Cited PapersA Design and Analysis of RCD Oscillation Suppression Circuit for Marx Pulse Generator
Marx circuit is widely used in pulse-generating devices. However, in practical applications, the discharge loop of the Marx often includes stray capacitance and inductance, which can cause oscillations at the leading edge of the pulse. This article proposes an resistor-capacitor-diode (RCD) snubber circuit connected to the load in parallel to suppress waveform oscillations. First, the design of the RCD snubber circuit for the Marx pulse generator is presented, including the derivation of the equivalent circuit and characteristic equations. Next, the root locus method is applied to the analyzed parameters of the snubber circuit, determining the appropriate ranges of capacitance and resistance values for the RCD. Additionally, PSPICE simulation software is employed to verify the pulse oscillation suppression effectiveness of the RCD snubber circuit. Finally, the performance of the proposed RCD snubber circuit is tested on a Marx generator with 4 kV output voltage, 1 Hz frequency, and 500 ns pulsewidth. The test results demonstrate that the RCD snubber circuit has a great effect of oscillation suppression, which decreases the pules overshoot from 685 to 207 V, achieving a 69.8% reduction.
- Top Cited Papers
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3233-3243
Potential of Ultrashort Pulsed Electric Fields to Disrupt Dense Structure in Glioma Tumors
Two major reasons why chemotherapy and immunotherapy have limited efficacy in treating gliomas are the blood-brain barrier and the dense, solid structure of the glioma. Pulsed electric fields have been a powerful tool for ablating solid tumors, and narrowing pulse duration can improve the field homogeneity penetrating into the tumor. In this study, we used multicellular tumor spheroids (MCTSs) as a model to explore the potential of ultrashort nanosecond pulses to inhibit tumor cell activity while disrupting their dense drug-resistant barriers. Exposure to ultrashort pulsed electric fields can significantly inhibit the viability of U-87 MG, C6, and GL261 spheroids, as indicated by reduced intracellular ATP content. Meanwhile, the proliferative abilities of tumor cells were suppressed, as evidenced by reduced Ki67 protein expression. In addition, it is notable that, after exposure to electric fields, the volume of spheroids increased dramatically. We hypothesize that ultrashort pulsed electric fields can reduce tumor compactness, thereby facilitating drug delivery for immunotherapy and chemotherapy. Immunofluorescence results showed that the cell-cell junction was broken by ultrashort pulsed electric fields with lower expression of adherens junction protein N-cadherin and tight junction protein ZO-1. It is evidenced that the capability of ultrashort pulsed electric fields to downregulate the intercellular adherence, as well as suppress the epithelial-mesenchymal transition, a key process of metastasis of cancer cells. At last, aqueous fluorescent nanoparticles were applied to simulate the anticancer drug or therapeutic antibodies. Under the supervision of fluorescence microscopy, the degree of nanoparticles penetrating into the spheroids was positively related to the number of ultrashort pulsed electric fields, marked with a higher fluorescent signal from the inner quiescent zone or a necrotic core. In conclusion, we emphasize that ultrashort pulsed electric fields could be promising for downgrading the compactness of glioma tumors, being a powerful assisted therapy for the delivery of anticancer drugs and therapeutic antibodies.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3233-3243
Top Cited PapersPotential of Ultrashort Pulsed Electric Fields to Disrupt Dense Structure in Glioma Tumors
Two major reasons why chemotherapy and immunotherapy have limited efficacy in treating gliomas are the blood-brain barrier and the dense, solid structure of the glioma. Pulsed electric fields have been a powerful tool for ablating solid tumors, and narrowing pulse duration can improve the field homogeneity penetrating into the tumor. In this study, we used multicellular tumor spheroids (MCTSs) as a model to explore the potential of ultrashort nanosecond pulses to inhibit tumor cell activity while disrupting their dense drug-resistant barriers. Exposure to ultrashort pulsed electric fields can significantly inhibit the viability of U-87 MG, C6, and GL261 spheroids, as indicated by reduced intracellular ATP content. Meanwhile, the proliferative abilities of tumor cells were suppressed, as evidenced by reduced Ki67 protein expression. In addition, it is notable that, after exposure to electric fields, the volume of spheroids increased dramatically. We hypothesize that ultrashort pulsed electric fields can reduce tumor compactness, thereby facilitating drug delivery for immunotherapy and chemotherapy. Immunofluorescence results showed that the cell-cell junction was broken by ultrashort pulsed electric fields with lower expression of adherens junction protein N-cadherin and tight junction protein ZO-1. It is evidenced that the capability of ultrashort pulsed electric fields to downregulate the intercellular adherence, as well as suppress the epithelial-mesenchymal transition, a key process of metastasis of cancer cells. At last, aqueous fluorescent nanoparticles were applied to simulate the anticancer drug or therapeutic antibodies. Under the supervision of fluorescence microscopy, the degree of nanoparticles penetrating into the spheroids was positively related to the number of ultrashort pulsed electric fields, marked with a higher fluorescent signal from the inner quiescent zone or a necrotic core. In conclusion, we emphasize that ultrashort pulsed electric fields could be promising for downgrading the compactness of glioma tumors, being a powerful assisted therapy for the delivery of anticancer drugs and therapeutic antibodies.
- 25 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (4) , 478-486
A Single-Driver Marx Generator Based on Series-Connected Switches With High Synchronization
As the applications of pulse generators continue to develop in a variety of fields, so do the requirements for pulse generators. The development of pulse generators is facing many key issues, such as high-voltage drive isolation, compact design, and weight reduction. In this regard, a single-driver Marx generator (SDMG) based on series-connected switches (SCSs) is proposed in this article. The proposed SCS module improves the voltage withstand capability of each Marx stage while ensuring good synchronization of the switches, thus reducing the number of Marx stages. Moreover, in the whole Marx generator, only one switch needs to be triggered by the driver; the rest of the switches can be self-triggered by coupling capacitors. With the reduction in the drivers and Marx stages, the size and the cost of Marx circuits are significantly reduced. The working principle is first analyzed. Then, through the simulation, the proposed SCS module is verified to have a higher switching synchronization compared to the related topologies previously proposed. Finally, an SDMG prototype based on the SCS is developed. The output parameters of the SDMG are tested. The test result shows that the SDMG can output pulse with a voltage of 12 kV and a rise time of 69.5 ns. The pulsewidth can be flexibly adjusted from 200 to 1000 ns, and the size of the generator is very small, only $13\times 6\times 2.5$ cm.
- 25 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 53 (4) , 478-486
A Single-Driver Marx Generator Based on Series-Connected Switches With High Synchronization
As the applications of pulse generators continue to develop in a variety of fields, so do the requirements for pulse generators. The development of pulse generators is facing many key issues, such as high-voltage drive isolation, compact design, and weight reduction. In this regard, a single-driver Marx generator (SDMG) based on series-connected switches (SCSs) is proposed in this article. The proposed SCS module improves the voltage withstand capability of each Marx stage while ensuring good synchronization of the switches, thus reducing the number of Marx stages. Moreover, in the whole Marx generator, only one switch needs to be triggered by the driver; the rest of the switches can be self-triggered by coupling capacitors. With the reduction in the drivers and Marx stages, the size and the cost of Marx circuits are significantly reduced. The working principle is first analyzed. Then, through the simulation, the proposed SCS module is verified to have a higher switching synchronization compared to the related topologies previously proposed. Finally, an SDMG prototype based on the SCS is developed. The output parameters of the SDMG are tested. The test result shows that the SDMG can output pulse with a voltage of 12 kV and a rise time of 69.5 ns. The pulsewidth can be flexibly adjusted from 200 to 1000 ns, and the size of the generator is very small, only $13\times 6\times 2.5$ cm.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2138-2146
Nanosecond Pulsed Bipolar Cancellation of the Killing Effect on Glioblastoma
Objective: Glioblastoma (GBM) is the deadliest type of cancer and current clinical treatments for malignant gliomas have many side effects. The article discusses the possibility that nanosecond pulsed electric fields (nsPEFs) can be focused on tumors for local killing. As well as the possibility of utilizing the CANCAN (canceled bipolar) effect to reduce neurostimulation and thus overcome side effects such as seizures and edema. Method: In this paper, we use cell ablation and viability experiments to investigated the BPC (Bipolar cancellation) effect of U87-MG cells under the action of nsPEFs of various pulse numbers and the electric field amplitude. Results: The results showed that maximum BPC efficiency (163.9%) was obtained with nsPEFs of 15 kV/cm and 15 pulses, and unipolar nsPEFs of 20 kV/cm and 15 pulses were able to achieve a killing effect of 90% with cell suspension, then this electric field is used as a reference for the ablation experiments. Conclusion: Cell ablation experiments found that the electric field threshold of 3D (3D-like tissue) cell ablation (5.805 ± 1.455 kV/cm) is lower than that of monolayer wall cells (8.95 ± 0.75 kV/cm), which can cause a larger ablation area under the same pulsed electric field conditions. In addition, the BPC effect was more significant for 3D cells, but the trends of ablation area and BPC efficiency were similar when modulating the number of pulses.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2138-2146
Nanosecond Pulsed Bipolar Cancellation of the Killing Effect on Glioblastoma
Objective: Glioblastoma (GBM) is the deadliest type of cancer and current clinical treatments for malignant gliomas have many side effects. The article discusses the possibility that nanosecond pulsed electric fields (nsPEFs) can be focused on tumors for local killing. As well as the possibility of utilizing the CANCAN (canceled bipolar) effect to reduce neurostimulation and thus overcome side effects such as seizures and edema. Method: In this paper, we use cell ablation and viability experiments to investigated the BPC (Bipolar cancellation) effect of U87-MG cells under the action of nsPEFs of various pulse numbers and the electric field amplitude. Results: The results showed that maximum BPC efficiency (163.9%) was obtained with nsPEFs of 15 kV/cm and 15 pulses, and unipolar nsPEFs of 20 kV/cm and 15 pulses were able to achieve a killing effect of 90% with cell suspension, then this electric field is used as a reference for the ablation experiments. Conclusion: Cell ablation experiments found that the electric field threshold of 3D (3D-like tissue) cell ablation (5.805 ± 1.455 kV/cm) is lower than that of monolayer wall cells (8.95 ± 0.75 kV/cm), which can cause a larger ablation area under the same pulsed electric field conditions. In addition, the BPC effect was more significant for 3D cells, but the trends of ablation area and BPC efficiency were similar when modulating the number of pulses.
- Top Cited Papers
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74, 1-10
A Bipolar Pulse Rising Edge Steepening Circuit Based on Diode Reverse Recovery
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74, 1-10
Top Cited PapersA Bipolar Pulse Rising Edge Steepening Circuit Based on Diode Reverse Recovery
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (3) , 496-510
Parallel Resonant Magnetic Field Generator for Biomedical Applications
In recent years, pulsed magnetic field (PMF) have attracted significant attention as a non-invasive electroporation method in the biomedical field. To further explore the biomedical effects generated by oscillating PMF, we designed a novel PMF generator for biomedical research. Based on resonance principles, the designed generator outputs sinusoidal oscillating PMF. To validate the feasibility and application value of the designed topology, a miniaturized platform was constructed using a selected multi-turn solenoid coil. The output performance of the generator was tested under different discharge voltage levels. The results revealed that the current multiplication factor remained consistently around 2 times, with the energy efficiency and circuit quality factor maintained at 82% and above 4.5, respectively. In addition, the generator’s ability to flexibly modulate the number of pulse oscillations was demonstrated. The compatibility of the designed coil parameters and generator circuit parameters was analyzed, with tests on the effects of coil resistance and switch action time on the generator’s output performance. Based on the magnetic field action platform, a simulation model of the actual scale coil was established. The spatial and temporal distribution of the magnetic field, induced electric field, and power transmission in the target area were described from multiple angles. Finally, biological experiments conducted using the constructed generator revealed the synergistic effect of sinusoidal oscillating PMF combined with drugs in tumor cell killing.
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (3) , 496-510
Parallel Resonant Magnetic Field Generator for Biomedical Applications
In recent years, pulsed magnetic field (PMF) have attracted significant attention as a non-invasive electroporation method in the biomedical field. To further explore the biomedical effects generated by oscillating PMF, we designed a novel PMF generator for biomedical research. Based on resonance principles, the designed generator outputs sinusoidal oscillating PMF. To validate the feasibility and application value of the designed topology, a miniaturized platform was constructed using a selected multi-turn solenoid coil. The output performance of the generator was tested under different discharge voltage levels. The results revealed that the current multiplication factor remained consistently around 2 times, with the energy efficiency and circuit quality factor maintained at 82% and above 4.5, respectively. In addition, the generator’s ability to flexibly modulate the number of pulse oscillations was demonstrated. The compatibility of the designed coil parameters and generator circuit parameters was analyzed, with tests on the effects of coil resistance and switch action time on the generator’s output performance. Based on the magnetic field action platform, a simulation model of the actual scale coil was established. The spatial and temporal distribution of the magnetic field, induced electric field, and power transmission in the target area were described from multiple angles. Finally, biological experiments conducted using the constructed generator revealed the synergistic effect of sinusoidal oscillating PMF combined with drugs in tumor cell killing.
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (7) , 2940-2947
A Pulse Rising Edge Steepening Circuit Design for Marx Generators
In many applications of Marx generators, it is very common to introduce additional stray inductance caused by lengthened leads. It will cause the problem of slowing down the rising edge of the pulse, which will greatly limit the generation of short pulsewidth and fast edge pulses. To solve this problem, this article proposes a pulse rising edge steepening circuit (PRESC) topology based on the diode reverse recovery process. The PRESC is connected in parallel to the load and consists of a low-voltage dc supply, a resistor, a diode, and a capacitor. The working principle is analyzed, and the steepening efficiency under different working conditions is simulated. Finally, a Marx generator was used to test the performance of the PRESC. The results show that at the test condition of 3-kV output voltage, 1-Hz frequency, and 500-ns pulsewidth, the PRESC can optimally reduce the rising edge from 86.2 to 40.9 ns.
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (7) , 2940-2947
A Pulse Rising Edge Steepening Circuit Design for Marx Generators
In many applications of Marx generators, it is very common to introduce additional stray inductance caused by lengthened leads. It will cause the problem of slowing down the rising edge of the pulse, which will greatly limit the generation of short pulsewidth and fast edge pulses. To solve this problem, this article proposes a pulse rising edge steepening circuit (PRESC) topology based on the diode reverse recovery process. The PRESC is connected in parallel to the load and consists of a low-voltage dc supply, a resistor, a diode, and a capacitor. The working principle is analyzed, and the steepening efficiency under different working conditions is simulated. Finally, a Marx generator was used to test the performance of the PRESC. The results show that at the test condition of 3-kV output voltage, 1-Hz frequency, and 500-ns pulsewidth, the PRESC can optimally reduce the rising edge from 86.2 to 40.9 ns.
- Top Cited Papers
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (10) , 12086-12099
A Fast-Edge Square-Wave Adjustable Pulse Current Generator Based on Coupling Inductor
In order to solve problems, such as the nonadjustable drive pulsewidth of semiconductor lasers, in this article, an all-solid-state modular pulse current generator (PCG) topology based on a coupling inductor is proposed. Each stage of the PCG consists of one inductor, two switches, and a diode. The inductors are charged in series and discharged parallel to the load by controlling the timing. The design of the coupling inductor makes it possible to increase the energy storage density of the system. To reduce the requirement for a high-voltage power supply, the capacitor is first charged by the dc power supply, and then charge the energy storage inductor. Theoretical analysis, simulation, and prototype development verify the correctness and feasibility of the PCG. A seven-stage PCG prototype is developed: at a charging voltage of 0–500 V, an adjustable output of 0–200 A is achieved. The maximum pulsewidth can reach 5 μ s with a rise time and fall time of 100 ns at resistive–capacitive load. The repetition frequency can reach 100 Hz. Finally, the PCG is successfully applied to laser arrays.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (10) , 12086-12099
Top Cited PapersA Fast-Edge Square-Wave Adjustable Pulse Current Generator Based on Coupling Inductor
In order to solve problems, such as the nonadjustable drive pulsewidth of semiconductor lasers, in this article, an all-solid-state modular pulse current generator (PCG) topology based on a coupling inductor is proposed. Each stage of the PCG consists of one inductor, two switches, and a diode. The inductors are charged in series and discharged parallel to the load by controlling the timing. The design of the coupling inductor makes it possible to increase the energy storage density of the system. To reduce the requirement for a high-voltage power supply, the capacitor is first charged by the dc power supply, and then charge the energy storage inductor. Theoretical analysis, simulation, and prototype development verify the correctness and feasibility of the PCG. A seven-stage PCG prototype is developed: at a charging voltage of 0–500 V, an adjustable output of 0–200 A is achieved. The maximum pulsewidth can reach 5 μ s with a rise time and fall time of 100 ns at resistive–capacitive load. The repetition frequency can reach 100 Hz. Finally, the PCG is successfully applied to laser arrays.