Víctor Iván Guerrero-Benítez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Víctor Iván Guerrero-Benítez has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Febe Carolina Vázquez-Vázquez
Dental Materials and Biomaterials Laboratory, Division of Graduate Studies and Research, Faculty of Dentistry, Universidad Nacional Autónoma de México (UNAM), Ciudad Universitaria, Mexico City 04510, Mexico
1 shared publication Israel Alfonso Núñez-Tapia
Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México, Coyoacan, Mexico
1 shared publication- Marco Antonio Alvarez-Perez
Laboratorio de Bioingeniería de Tejidos, División de Estudios de Posgrado e Investigación, Facultad de Odontología, UNAM, Circuito Exterior s/n Cd. Universitaria, Mexico City C.P. 04510, Mexico
1 shared publication - Marine Ortiz-Magdaleno
PhD, Faculty of Stomatology, Autonomous University of San Luis Potosí, San Luis Potosí. Av. Dr. Manuel Nava #2, Zona Universitaria, 78290, San Luis Potosí, S.L.P. México
1 shared publication - Osmar Alejandro Chanes-Cuevas
Dental Materials and Biomaterials Research Laboratory, DEPeI, Faculty of Dentistry, National Autonomous University of Mexico (UNAM), External Circuit, Coyoacán, Mexico City 04510, Mexico
1 shared publication
Latest Publications
- Open Access
- 16 January 2024
- Published by Springer Nature in Biomedical Materials & Devices
- Vol. 2 (2) , 1143-1150
Multifunctional Nanocomposite Membranes Containing TiO2 Developed by Air-Jet-Spun Fibers for Tissue Engineering
The incorporation of inorganic nanoparticles (NP) into nanofibrous polymeric membranes (NPM) is an attractive approach to developing multifunctional nanocomposites. The purpose of this study was to incorporate titanium dioxide (TiO2) NP into NPM to enhance the overall properties. Polycaprolactone (PCL) membranes with TiO2-NP (0.2 wt%) was fabricated by means of the Air-Jet Spinning (AJS) technique. The physicochemical characterization of the PCL-TiO2-NPM was performed by X-ray powder diffraction (XRD), the morphology was observed under scanning electron microscopy (SEM), and tensile strength and Young’s moduli were evaluated using an INSTRON Universal Testing Machine. In-vitro biocompatibility was evaluated in terms of cell adhesion and cell proliferation using human fetal osteoblasts. The results obtained demonstrated that TiO2-NP added to the PCL-NPM increases the values of tensile strength and Young’s moduli (p < 0.008 and p < 0.043) with respect to PCL-NPM without TiO2-NP. XRD exhibited the characteristic peaks of PCL at 21.3° and 23.7° and of TiO2 at 36°. The SEM micrographs revealed a random distribution with interconnected micropores. Cell adhesion and proliferation increased according to the time of the culture; only after the first period of cell culture was there a significant difference in cell proliferation (p < 0.05). The possible potential application of this PCL-PNM by Air-Jet Spinning (AJS) in tissue engineering could favor bone regeneration due that the addition of TiO2-NP.
- 16 January 2024
- Published by Springer Nature in Biomedical Materials & Devices
- Vol. 2 (2) , 1143-1150
Open AccessMultifunctional Nanocomposite Membranes Containing TiO2 Developed by Air-Jet-Spun Fibers for Tissue Engineering
The incorporation of inorganic nanoparticles (NP) into nanofibrous polymeric membranes (NPM) is an attractive approach to developing multifunctional nanocomposites. The purpose of this study was to incorporate titanium dioxide (TiO2) NP into NPM to enhance the overall properties. Polycaprolactone (PCL) membranes with TiO2-NP (0.2 wt%) was fabricated by means of the Air-Jet Spinning (AJS) technique. The physicochemical characterization of the PCL-TiO2-NPM was performed by X-ray powder diffraction (XRD), the morphology was observed under scanning electron microscopy (SEM), and tensile strength and Young’s moduli were evaluated using an INSTRON Universal Testing Machine. In-vitro biocompatibility was evaluated in terms of cell adhesion and cell proliferation using human fetal osteoblasts. The results obtained demonstrated that TiO2-NP added to the PCL-NPM increases the values of tensile strength and Young’s moduli (p < 0.008 and p < 0.043) with respect to PCL-NPM without TiO2-NP. XRD exhibited the characteristic peaks of PCL at 21.3° and 23.7° and of TiO2 at 36°. The SEM micrographs revealed a random distribution with interconnected micropores. Cell adhesion and proliferation increased according to the time of the culture; only after the first period of cell culture was there a significant difference in cell proliferation (p < 0.05). The possible potential application of this PCL-PNM by Air-Jet Spinning (AJS) in tissue engineering could favor bone regeneration due that the addition of TiO2-NP.