Peter Sinkjaer Kenney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peter Sinkjaer Kenney has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bryan Lim
Peninsula Health, Melbourne, VIC, Australia
2 shared publications - Ishith Seth
Peninsula Health, Melbourne, VIC, Australia
2 shared publications - Warren Matthew Rozen
Peninsula Health
2 shared publications Anders B. Eng. Jakobsen
D Innovation, Aarhus University Hospital, Aarhus, Denmark
1 shared publicationBirgitte Jul Kiil
Department of Plastic and Breast Surgery, Aarhus University Hospital, Aarhus, Denmark
1 shared publicationDylan Gracias
Department of Plastic Surgery, Peninsula Health, Melbourne, Victoria 3199, Australia
1 shared publication
Latest Publications
- Open Access
- 17 April 2025
- Published by Elsevier in JPRAS Open
- Vol. 45, 1-19
The use of extended reality in microsurgical free flap planning – A systematic review
- 17 April 2025
- Published by Elsevier in JPRAS Open
- Vol. 45, 1-19
Open AccessThe use of extended reality in microsurgical free flap planning – A systematic review
- Open Access
Perforator Selection with Computed Tomography Angiography for Unilateral Breast Reconstruction: A Clinical Multicentre Analysis
Background and Objectives: Despite CTAs being critical for preoperative planning in autologous breast reconstruction, experienced plastic surgeons may have differing preferences for which side of the abdomen to use for unilateral breast reconstruction. Large language models (LLMs) have the potential to assist medical imaging interpretation. This study compares the perforator selection preferences of experienced plastic surgeons with four popular LLMs based on CTA images for breast reconstruction. Materials and Methods: Six experienced plastic surgeons from Australia, the US, Italy, Denmark, and Argentina reviewed ten CTA images, indicated their preferred side of the abdomen for unilateral breast reconstruction and recommended the type of autologous reconstruction. The LLMs were prompted to do the same. The average decisions were calculated, recorded in suitable tables, and compared. Results: The six consultants predominantly recommend the DIEP procedure (83%). This suggests experienced surgeons feel more comfortable raising DIEP than TRAM flaps, which they recommended only 3% of the time. They also favoured MS TRAM and SIEA less frequently (11% and 2%, respectively). Three LLMs—ChatGPT-4o, ChatGPT-4, and Bing CoPilot—exclusively recommended DIEP (100%), while Claude suggested DIEP 90% and MS TRAM 10%. Despite minor variations in side recommendations, consultants and AI models clearly preferred DIEP. Conclusions: Consultants and LLMs consistently preferred DIEP procedures, indicating strong confidence among experienced surgeons, though LLMs occasionally deviated in recommendations, highlighting limitations in their image interpretation capabilities. This emphasises the need for ongoing refinement of AI-assisted decision support systems to ensure they align more closely with expert clinical judgment and enhance their reliability in clinical practice.
Open AccessPerforator Selection with Computed Tomography Angiography for Unilateral Breast Reconstruction: A Clinical Multicentre Analysis
Background and Objectives: Despite CTAs being critical for preoperative planning in autologous breast reconstruction, experienced plastic surgeons may have differing preferences for which side of the abdomen to use for unilateral breast reconstruction. Large language models (LLMs) have the potential to assist medical imaging interpretation. This study compares the perforator selection preferences of experienced plastic surgeons with four popular LLMs based on CTA images for breast reconstruction. Materials and Methods: Six experienced plastic surgeons from Australia, the US, Italy, Denmark, and Argentina reviewed ten CTA images, indicated their preferred side of the abdomen for unilateral breast reconstruction and recommended the type of autologous reconstruction. The LLMs were prompted to do the same. The average decisions were calculated, recorded in suitable tables, and compared. Results: The six consultants predominantly recommend the DIEP procedure (83%). This suggests experienced surgeons feel more comfortable raising DIEP than TRAM flaps, which they recommended only 3% of the time. They also favoured MS TRAM and SIEA less frequently (11% and 2%, respectively). Three LLMs—ChatGPT-4o, ChatGPT-4, and Bing CoPilot—exclusively recommended DIEP (100%), while Claude suggested DIEP 90% and MS TRAM 10%. Despite minor variations in side recommendations, consultants and AI models clearly preferred DIEP. Conclusions: Consultants and LLMs consistently preferred DIEP procedures, indicating strong confidence among experienced surgeons, though LLMs occasionally deviated in recommendations, highlighting limitations in their image interpretation capabilities. This emphasises the need for ongoing refinement of AI-assisted decision support systems to ensure they align more closely with expert clinical judgment and enhance their reliability in clinical practice.
- Top Cited PapersOpen Access
- 22 January 2024
- Published by Elsevier in JPRAS Open
- Vol. 39, 291-302
Impact of nutrition on skin wound healing and aesthetic outcomes: A comprehensive narrative review
- 22 January 2024
- Published by Elsevier in JPRAS Open
- Vol. 39, 291-302
Top Cited PapersOpen AccessImpact of nutrition on skin wound healing and aesthetic outcomes: A comprehensive narrative review
- Open Access
- 1 September 2023
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 11 (9) , e5282
Improving Visualization of Intramuscular Perforator Course: Augmented Reality Headsets for DIEP Flap Breast Reconstruction
Background: Augmented reality (AR) technology, exemplified by devices such as the Microsoft HoloLens 2, has gained interest for its potential applications in preoperative guidance. This study explores the use of AR technology for perforator identification during deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. Methods: A case series of five patients where an AR device was used to identify perforators during DIEP flap breast reconstruction is presented. The device was utilized to recognize preoperative perforators and map their extra- and intramuscular routes. Sound and/or color Doppler confirmation was used to verify the findings. Results: In all five cases, the AR device successfully identified preoperative perforators and delineated their extra- and intramuscular routes. AR technology in perioperative visualization of vasculature offers the potential to enhance surgical precision and reduce operative times. By providing an augmented three-dimensional overlay of patients’ vascular structures, AR can facilitate a more comprehensive understanding of individual anatomy, ultimately improving surgical outcomes. Conclusions: AR technology shows promise in enhancing perforator identification efficiency and deepening understanding of perforator trajectories during preoperative planning. Nonetheless, additional research is needed to establish whether the advantages of AR technology warrant its widespread adoption for perforator identification.
- 1 September 2023
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 11 (9) , e5282
Open AccessImproving Visualization of Intramuscular Perforator Course: Augmented Reality Headsets for DIEP Flap Breast Reconstruction
Background: Augmented reality (AR) technology, exemplified by devices such as the Microsoft HoloLens 2, has gained interest for its potential applications in preoperative guidance. This study explores the use of AR technology for perforator identification during deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. Methods: A case series of five patients where an AR device was used to identify perforators during DIEP flap breast reconstruction is presented. The device was utilized to recognize preoperative perforators and map their extra- and intramuscular routes. Sound and/or color Doppler confirmation was used to verify the findings. Results: In all five cases, the AR device successfully identified preoperative perforators and delineated their extra- and intramuscular routes. AR technology in perioperative visualization of vasculature offers the potential to enhance surgical precision and reduce operative times. By providing an augmented three-dimensional overlay of patients’ vascular structures, AR can facilitate a more comprehensive understanding of individual anatomy, ultimately improving surgical outcomes. Conclusions: AR technology shows promise in enhancing perforator identification efficiency and deepening understanding of perforator trajectories during preoperative planning. Nonetheless, additional research is needed to establish whether the advantages of AR technology warrant its widespread adoption for perforator identification.