Matthäus Krantz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matthäus Krantz has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Christian Enss
Kirchhoff Institute for Physics, Heidelberg University, Heidelberg, Germany
2 shared publications - Sebastian Kempf
Karlsruher Institut fr Technologie, Karlsruhe, Germany
2 shared publications - Andreas Fleischmann
Kirchhoff Institute for Physics, Heidelberg University, Heidelberg, Germany
1 shared publication - Benedikt Maier
Imperial College London
1 shared publication - Christof Schötz
Munich Climate Center and Earth System Modelling Group, Department of Aerospace and Geodesy, TUM School of Engineering and Design, Technical University of Munich, Munich, Germany
1 shared publication - Daniel Hengstler
University Heidelberg
1 shared publication
Latest Publications
- Open Access
- 15 January 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (3)
Magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution x-ray emission spectroscopy
We present two variants of a magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-superconducting quantum interference device readout for high-resolution x-ray emission spectroscopy. Each variant employs two overhanging gold absorbers with a sensitive area of 150 × 150 μm2 and a thickness of 3 μm, thus providing a thickness related quantum efficiency of >98% for photons up to 5 keV and >50% for photons up to 10 keV. The first variant operated nominally but suffered from Joule power dissipation of the Josephson junction shunt resistors, athermal phonon loss, and slew rate limitations of the overall setup. Overall, it only achieved an energy resolution of ΔEFWHM=8.9 eV for 5.9 keV photons. In the second variant, we introduced an innovative tetrapod absorber geometry as well as a membrane technique for diverting dissipated heat away from the temperature sensors. When all mitigations are applied optimally, the second variant achieves an energy resolution of ΔEFWHM=1.25(18) eV for 5.9 keV photons and hence provides the present best energy resolving power E/ΔEFWHM among all existing energy-dispersive detectors for soft and tender x-rays.
- 15 January 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (3)
Open AccessMagnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution x-ray emission spectroscopy
We present two variants of a magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-superconducting quantum interference device readout for high-resolution x-ray emission spectroscopy. Each variant employs two overhanging gold absorbers with a sensitive area of 150 × 150 μm2 and a thickness of 3 μm, thus providing a thickness related quantum efficiency of >98% for photons up to 5 keV and >50% for photons up to 10 keV. The first variant operated nominally but suffered from Joule power dissipation of the Josephson junction shunt resistors, athermal phonon loss, and slew rate limitations of the overall setup. Overall, it only achieved an energy resolution of ΔEFWHM=8.9 eV for 5.9 keV photons. In the second variant, we introduced an innovative tetrapod absorber geometry as well as a membrane technique for diverting dissipated heat away from the temperature sensors. When all mitigations are applied optimally, the second variant achieves an energy resolution of ΔEFWHM=1.25(18) eV for 5.9 keV photons and hence provides the present best energy resolving power E/ΔEFWHM among all existing energy-dispersive detectors for soft and tender x-rays.
- 1 November 2015
- Published by IOP Publishing in Physica Scripta
- Vol. T166 (T166) , 014054
Towards FAIR: first measurements of metallic magnetic calorimeters for high-resolution x-ray spectroscopy at GSI
- 1 November 2015
- Published by IOP Publishing in Physica Scripta
- Vol. T166 (T166) , 014054
Towards FAIR: first measurements of metallic magnetic calorimeters for high-resolution x-ray spectroscopy at GSI